[Meer zien]A Balancing Authority notices that Operating Reserve has steadily declined throughout the hour. What is the most likely cause? 
 
a) Loss of a large generator in the area 
b) An inaccurate load forecast 
c) Loss of a major transmission line 
d) A malfunction of EMS 
b) An inaccurate load forecast 
 ...
Voorbeeld 2 van de 10 pagina's
In winkelwagenA Balancing Authority notices that Operating Reserve has steadily declined throughout the hour. What is the most likely cause? 
 
a) Loss of a large generator in the area 
b) An inaccurate load forecast 
c) Loss of a major transmission line 
d) A malfunction of EMS 
b) An inaccurate load forecast 
 ...
Common standard time period for station battery to handle outage of AC power to chargers 
8-12 hours 
 
 
 
Time to restore data exchange redundancy when redundancy testing by RC/TOP/BA deemed unsuccessful 
2 hours 
 
 
 
Transition period to backup control facility (fully functioning) 
2 hours 
 
 ...
Voorbeeld 2 van de 9 pagina's
In winkelwagenCommon standard time period for station battery to handle outage of AC power to chargers 
8-12 hours 
 
 
 
Time to restore data exchange redundancy when redundancy testing by RC/TOP/BA deemed unsuccessful 
2 hours 
 
 
 
Transition period to backup control facility (fully functioning) 
2 hours 
 
 ...
. If a 500 kV transmission line with a surge impedance loading of 800 MW is currently loaded at 1400 MW, which of the following events would most likely occur? 
 
a. Generator MVAR output would increase 
b. All system capacitors would trip off-line 
c. Generator MVAR output would decrease 
d. All au...
Voorbeeld 4 van de 55 pagina's
In winkelwagen. If a 500 kV transmission line with a surge impedance loading of 800 MW is currently loaded at 1400 MW, which of the following events would most likely occur? 
 
a. Generator MVAR output would increase 
b. All system capacitors would trip off-line 
c. Generator MVAR output would decrease 
d. All au...
A transmission line is operating with a voltage phase angle different of 30 degrees between the sending Vs and the receiving bus Vr. If the receiving end load is suddenly increased, the voltage phase angle difference will be? 
The phase angle will increase. When load is increased phase angle will in...
Voorbeeld 3 van de 24 pagina's
In winkelwagenA transmission line is operating with a voltage phase angle different of 30 degrees between the sending Vs and the receiving bus Vr. If the receiving end load is suddenly increased, the voltage phase angle difference will be? 
The phase angle will increase. When load is increased phase angle will in...
Frequency Bias and Jointly Owned Units (JOU) 
BAs that use dynamic schedule or pseudo-ties for a jointly owned unit share responsibility for it in their bias settings. 
Fixed schedules for JOU require host BA to include total response for them in their bias setting. 
 
 
 
Frequency Bias and BA freq...
Voorbeeld 2 van de 14 pagina's
In winkelwagenFrequency Bias and Jointly Owned Units (JOU) 
BAs that use dynamic schedule or pseudo-ties for a jointly owned unit share responsibility for it in their bias settings. 
Fixed schedules for JOU require host BA to include total response for them in their bias setting. 
 
 
 
Frequency Bias and BA freq...
The Reliability Coordinator just informed you of a slow time error correction which will begin at the top of the next hour. Your EMS system will not let you change your scheduled frequency. Your Frequency Bias Setting is -100 MW/.1Hz. What action should you take? 
 
A) Increase Net Interchange Sched...
Voorbeeld 4 van de 75 pagina's
In winkelwagenThe Reliability Coordinator just informed you of a slow time error correction which will begin at the top of the next hour. Your EMS system will not let you change your scheduled frequency. Your Frequency Bias Setting is -100 MW/.1Hz. What action should you take? 
 
A) Increase Net Interchange Sched...
What entity balances generation and monitors/employs contingency reserves? 
Balancing Authority (BA) 
 
 
 
What entity has the widest system view and is the "supervisor"? 
Reliability coordinator (RC) 
 
 
 
What entity monitors transmission lines and operates tap-changers, breakers, capacitors, ...
Voorbeeld 3 van de 21 pagina's
In winkelwagenWhat entity balances generation and monitors/employs contingency reserves? 
Balancing Authority (BA) 
 
 
 
What entity has the widest system view and is the "supervisor"? 
Reliability coordinator (RC) 
 
 
 
What entity monitors transmission lines and operates tap-changers, breakers, capacitors, ...
Studenten hebben al meer dan 850.000 samenvattingen beoordeeld. Zo weet jij zeker dat je de beste keuze maakt!
Geen gedoe — betaal gewoon eenmalig met iDeal, Bancontact of creditcard en je bent klaar. Geen abonnement nodig.
Studenten maken samenvattingen voor studenten. Dat betekent: actuele inhoud waar jij écht wat aan hebt. Geen overbodige details!
Je krijgt een PDF, die direct beschikbaar is na je aankoop. Het gekochte document is altijd, overal en oneindig toegankelijk via je profiel.
Onze tevredenheidsgarantie zorgt ervoor dat je altijd een studiedocument vindt dat goed bij je past. Je vult een formulier in en onze klantenservice regelt de rest.
Stuvia is een marktplaats, je koop dit document dus niet van ons, maar van verkoper JUICYGRADES. Stuvia faciliteert de betaling aan de verkoper.
Nee, je koopt alleen deze samenvatting voor $25.49. Je zit daarna nergens aan vast.
4,6 sterren op Google & Trustpilot (+1000 reviews)
Afgelopen 30 dagen zijn er 64670 samenvattingen verkocht
Opgericht in 2010, al 15 jaar dé plek om samenvattingen te kopen