Package deal
cbspd tests compilation bundle
cbspd tests compilation bundle
[Show more]cbspd tests compilation bundle
[Show more]What should the sterilizer access area pressure be? correct answer: Negative w/10 air exchanges per hour 
 
What two steps are involved in decontamination? correct answer: 1. Manual and/or automated mechanical cleaning 
2. application of a thermal or chemical disinfection process 
 
Define Cleanin...
Preview 2 out of 9 pages
Add to cartWhat should the sterilizer access area pressure be? correct answer: Negative w/10 air exchanges per hour 
 
What two steps are involved in decontamination? correct answer: 1. Manual and/or automated mechanical cleaning 
2. application of a thermal or chemical disinfection process 
 
Define Cleanin...
Functions of SPD correct answer: Our functions are Decontamination, Assembly/Prep & Pack, Sterilization & Storage. 
 
Placement of Instrumentation on Sterilizer rack Top shelf correct answer: Peel packs tilted on edge/side 
 
Placement of Instrumentation on Sterilizer rack Middle shelf correct ans...
Preview 2 out of 10 pages
Add to cartFunctions of SPD correct answer: Our functions are Decontamination, Assembly/Prep & Pack, Sterilization & Storage. 
 
Placement of Instrumentation on Sterilizer rack Top shelf correct answer: Peel packs tilted on edge/side 
 
Placement of Instrumentation on Sterilizer rack Middle shelf correct ans...
A broken glass suction bottle is returned to Decontamination. Which of the following should the technician do? correct answer: Place it in an appropriate rigid container 
 
Safety Data Sheets (SDS) provide health and safety hazard and risk information on which of the following? correct answer: Che...
Preview 2 out of 7 pages
Add to cartA broken glass suction bottle is returned to Decontamination. Which of the following should the technician do? correct answer: Place it in an appropriate rigid container 
 
Safety Data Sheets (SDS) provide health and safety hazard and risk information on which of the following? correct answer: Che...
Why is it Important to evenly distribute large instruments in a set? correct answer: Extra condensation will make the set more difficult to dry. 
 
Which of the following best describes the overall role of the CS/SPD? correct answer: To provide dependable service to enhance patient care. 
 
Which ...
Preview 2 out of 6 pages
Add to cartWhy is it Important to evenly distribute large instruments in a set? correct answer: Extra condensation will make the set more difficult to dry. 
 
Which of the following best describes the overall role of the CS/SPD? correct answer: To provide dependable service to enhance patient care. 
 
Which ...
Semi critical devices should be processed by which disinfection method? correct answer: High-level disinfection (at least) 
 
Critical devices should be processed by which disinfection method? correct answer: Sterilization 
 
Non critical devices should be privy which disinfection method? correct ...
Preview 2 out of 8 pages
Add to cartSemi critical devices should be processed by which disinfection method? correct answer: High-level disinfection (at least) 
 
Critical devices should be processed by which disinfection method? correct answer: Sterilization 
 
Non critical devices should be privy which disinfection method? correct ...
Decontamination Area correct answer: Where soiled items are received and cleaned. *All levels for the same tray should be labeled w/a tag to identify the level number and set to which it belongs. 
 
Preparation and Packaging Area correct answer: where cleaned items are inspected, assembled, and pa...
Preview 4 out of 105 pages
Add to cartDecontamination Area correct answer: Where soiled items are received and cleaned. *All levels for the same tray should be labeled w/a tag to identify the level number and set to which it belongs. 
 
Preparation and Packaging Area correct answer: where cleaned items are inspected, assembled, and pa...
The main role of the sterile processing area is to correct answer: provide dependable reliable services to enhance the quality of patient care. 
 
Instruments sets and patient care equipment processing and distributing must be done accurately and timely so: correct answer: patient care is not adve...
Preview 2 out of 8 pages
Add to cartThe main role of the sterile processing area is to correct answer: provide dependable reliable services to enhance the quality of patient care. 
 
Instruments sets and patient care equipment processing and distributing must be done accurately and timely so: correct answer: patient care is not adve...
What is the first step in the decon process? correct answer: Cleaning with detergent. 
 
According to OSHA, what means are used to inactivate blood borne pathogens? correct answer: Disinfection 
 
The removal of contamination from an item to the extent necessary for further processing or for inten...
Preview 2 out of 6 pages
Add to cartWhat is the first step in the decon process? correct answer: Cleaning with detergent. 
 
According to OSHA, what means are used to inactivate blood borne pathogens? correct answer: Disinfection 
 
The removal of contamination from an item to the extent necessary for further processing or for inten...
Steam Using Gravity Displacement: Method of Killing correct answer: Denatures microorganism proteins 
 
Steam Using Gravity Displacement: Sterilant Used correct answer: Combination of steam and ambient air 
 
Steam Using Gravity Displacement: How do steam and ambient are sterilize? correct answer:...
Preview 2 out of 11 pages
Add to cartSteam Using Gravity Displacement: Method of Killing correct answer: Denatures microorganism proteins 
 
Steam Using Gravity Displacement: Sterilant Used correct answer: Combination of steam and ambient air 
 
Steam Using Gravity Displacement: How do steam and ambient are sterilize? correct answer:...
Main role of sterile processing is: correct answer: provide reliable services to enhance quality of patient care 
 
instruments sets and patient care equipment processing and distributing must be done accurately and timely so: correct answer: patient care is not adversely affected 
 
Ethics is cor...
Preview 3 out of 21 pages
Add to cartMain role of sterile processing is: correct answer: provide reliable services to enhance quality of patient care 
 
instruments sets and patient care equipment processing and distributing must be done accurately and timely so: correct answer: patient care is not adversely affected 
 
Ethics is cor...
Define Cleaning correct answer: "the removal of contamination from an item to the extent necessary for further processing or for the intended use" 
 
Define Decontamination correct answer: "the use of physical or chemical means to remove, inactivate, or destroy BBP on a surface or item to the p...
Preview 2 out of 10 pages
Add to cartDefine Cleaning correct answer: "the removal of contamination from an item to the extent necessary for further processing or for the intended use" 
 
Define Decontamination correct answer: "the use of physical or chemical means to remove, inactivate, or destroy BBP on a surface or item to the p...
Which of the following agencies regulates clearances for glutaraldehyde-based disinfectants? 
- OSHA 
- CDC 
- EPA 
- FDA correct answer: FDA 
 
Which agency is responsible for employee health and safety at work? 
- EPA 
- FDA 
- CDC 
- OSHA correct answer: OSHA 
 
Recommended practices are: 
- St...
Preview 2 out of 7 pages
Add to cartWhich of the following agencies regulates clearances for glutaraldehyde-based disinfectants? 
- OSHA 
- CDC 
- EPA 
- FDA correct answer: FDA 
 
Which agency is responsible for employee health and safety at work? 
- EPA 
- FDA 
- CDC 
- OSHA correct answer: OSHA 
 
Recommended practices are: 
- St...
Why is it important to evenly distribute large instruments in a set? A. Extra condensation will make the set more difficult to dry B. It came help with storage C. Easier to carry D. None of the above correct answer: A. Extra condensation will make the set more difficult to dry 
 
Which of the follo...
Preview 4 out of 36 pages
Add to cartWhy is it important to evenly distribute large instruments in a set? A. Extra condensation will make the set more difficult to dry B. It came help with storage C. Easier to carry D. None of the above correct answer: A. Extra condensation will make the set more difficult to dry 
 
Which of the follo...
Which of the following is a major cause of AER failures? correct answer: Using incorrect connectors 
 
Which agency requires that eyewash stations be available for emergency use? correct answer: OSHA (Occupational Safety and Health Administration) 
 
The OSHA Hazard Communication Standard requires...
Preview 2 out of 5 pages
Add to cartWhich of the following is a major cause of AER failures? correct answer: Using incorrect connectors 
 
Which agency requires that eyewash stations be available for emergency use? correct answer: OSHA (Occupational Safety and Health Administration) 
 
The OSHA Hazard Communication Standard requires...
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Stuvia is a marketplace, so you are not buying this document from us, but from seller Classroom. Stuvia facilitates payment to the seller.
No, you only buy these notes for $30.49. You're not tied to anything after your purchase.
4.6 stars on Google & Trustpilot (+1000 reviews)
79079 documents were sold in the last 30 days
Founded in 2010, the go-to place to buy study notes for 14 years now