EPA 608 EXAM BUNDLE(COMPLETE PACKAGE DEAL) Type 3| 50 Questions | Correct 100% Correct!!EPA 608 EXAM BUNDLE(COMPLETE PACKAGE DEAL) Type 3| 50 Questions | Correct 100% Correct!!EPA 608 EXAM BUNDLE(COMPLETE PACKAGE DEAL) Type 3| 50 Questions | Correct 100% Correct!!EPA 608 EXAM BUNDLE(COMPLETE PACKAG...

[Show more]
21 items

EPA 608 Type 3 Correct Questions & Answers(Rated A)

(0)
$11.99

On low pressure chillers, moisture typically enters the refrigerant system through - ANSWER air leaks from areas with gaskets or fittings The maximum test pressure for leak testing a low pressure centrifugal is: - ANSWER 10 psig Leak test and repair the chiller to reduce refrigerant loss from ...

View example

EPA 608 Type III Sample Test Questions & Answers

(0)
$10.99

Where do leaks commonly occur in low pressure systems? a. Evaporator b. Condenser c. Purge unit d. Gaskets or fittings - ANSWER d. Gaskets or fittings Where do leaks commonly occur in open-drive type compressor systems? a. Evaporator b. Condenser c. Shaft seal d. Cooling tower - ANSWER c....

View example

EPA 608 Practice exam Type 3| 50 Questions | Correct 100% Correct!!

(0)
$10.99

The maximum test pressure for leak testing a low-pressure centrifugal chiller is - ANSWER 10 psig Excessive operation of a purge system means - ANSWER The system has a leak on the sub-ambient pressure side of the system For a commercial refrigeration system with a charge of 50 pounds or more r...

View example

EPA 608 Type III Complete Questions & Answers!

(0)
$11.49

What do R-11 and R-123 refrigerants have in common? A. They are oxygen depleting B. They are Class I and II substances as defined by the EPA C. Both A and B D. Neither A nor B - ANSWER C. Both A and B What is the required evacuation level for recovering refrigerant from a low-pressure appli...

View example

EPA 608 Type III Practice Questions & Answers

(0)
$10.49

municipal water supply approximately how much refrigerant vapor is left in an average 350 ton R-11 chiller at 0 psig pressure once all the R-11 liquid has been removed? - ANSWER 100 lbs a rupture disc on a recovery vessel for low pressure refrigerant relieves at ____ - ANSWER 15 psig on a c...

View example

EPA 608 Type 3 Certifications Questions & Answers!

(0)
$10.99

When using recovery or recycling equipment manufactured or imported on or after Nov 15, 1993, the required level of evacuation for low pressure equipment is _____ Hg absolute: 30mm 25mm 15mm 20mm - ANSWER 25mm The EPA requires that all commercial and industrial process refrigeration systems...

View example

EPA 608 Type III Study Guide Correct 100% Correct!

(0)
$10.99

The state of the refrigerant entering the metering device is: - ANSWER High pressure liquid The following components are metering devices: - ANSWER Evaporator pressure regulator, Thermostatic expansion valve The state of the refrigerant entering the compressor is: - ANSWER Low pressure vapor ...

View example

EPA 608 Type III Correct Questions & Answers(SCORED A+ )

(0)
$10.99

Identify the pressure corresponding to 32 degrees F for R-123: ________. a) 23 inches of Hg vacuum b) 20 inches of Hg vacuum c) 17 inches of Hg vacuum d) 11 inches of Hg vacuum - ANSWER b) 20 inches of Hg vacuum A hydrostatic tube test kit is used to: _________. a) blow all water from th...

View example

EPA 608 Book Exam TYPE III CERTIFICATION CORRECT 100%(SCORED A+)

(0)
$11.99

Technicians maintaining, servicing, repairing or disposing of low-pressure appliances must be certified as - ANSWER Type III Technician or a Universal Technician. As of November 14, 1994, the sale of CFC and HCFC refrigerants is restricted to - ANSWER Certified technicians, NOTE: If EPA regulatio...

View example

EPA Type III Correct questions & Answers!

(0)
$10.49

What type of equipment can be worked on with Type III certification? - ANSWER low pressure The most efficient method of leak checking a charged low-pressure refrigeration unit is to - ANSWER pressurize the system by the use of controlled hot water or heater blankets When pressurizing a system,...

View example

EPA 608: Type III Correct 100% Correct!!

(0)
$10.99

Techs maintaining, servicing, repairing, or disposing of low pressure appliances must be certified as? - ANSWER Type III or universal technician As of what date was the sale of CFCs and HCFCs restricted to certified techs? - ANSWER Nov 14, 1994 Who is responsible to comply with changes in sect...

View example

EPA 608 Type III Correct Questions & Answers(Rated A)

(0)
$10.99

A typical setting for the high pressure cut-out control on a recovery unit used for evacuating the refrigerant from a low pressure chiller is: - ANSWER C) 10 psig. A charged low pressure refrigeration system can be efficiently leak checked by: - ANSWER D) raising system pressure by heating with c...

View example

EPA 608 - Type III Correct Questions & Answers

(0)
$10.99

technicians maintaining, servicing, repairing, or disposing of low-pressure appliances must be certified as: - ANSWER Type III or Universal Technician the owner &/or operator of the equipment is responsible for keeping: - ANSWER records including: leak inspections & any completed leak repair veri...

View example

EPA 608 Type III Exam Correct 100% Correct!!

(0)
$11.49

Before recovering refrigerant from a chiller suspected of having tube leaks,... - ANSWER ...drain the water sides of the evaporator and condenser. Draining the water sides helps to avoid the introduction of additional water into the system cause by the evacuation process and to prevent the water fro...

View example

EPA SECTION 608 TYPE III (2019 revision)Correct 100%!

(0)
$10.49

On low-pressure chillers, moisture most frequently enters the system through; a. air leaks in the rupture disc assembly. b. tube leaks in the evaporator. c. leaks from areas with gaskets or fittings. d. leaks from the charging service valve. - ANSWER c. leaks from areas with gaskets or fittings....

View example

EPA 608 TYPE III Complete Questions & Answers(Rated A)

(0)
$10.49

Which of the following best describes the refrigerant recovery process from an R-123 system? - ANSWER Start with liquid removal and then switch over to vapor recovery. Under ASHRAE Standard 34, R-134a is classified as; - ANSWER A1 When charging a low-pressure system, refrigerant should be intr...

View example

EPA 608 TYPE III Correct Questions & Answers!!

(0)
$10.99

A-1 - ANSWER refrigerants CFC-12, HCFC-22, HFC-134a are all classified as type what substances? 15 hg - ANSWER when recovering refrigerant from a medium pressure system with more than 200lbs of refrigerant, recover to a level of? 30% - ANSWER EPA requires that all industrial process refrigerat...

View example

EPA 608 TYPE III 203-2024 Latest Update!!

(0)
$9.99

A-1 - ANSWER refrigerants CFC-12, HCFC-22, HFC-134a are all classified as type what substances? 15 hg - ANSWER when recovering refrigerant from a medium pressure system with more than 200lbs of refrigerant, recover to a level of? 30% - ANSWER EPA requires that all industrial process refrigerat...

View example

EPA 608 Type III| QUESTIONS| Correct Answers!

(0)
$10.99

a Type III Technician or Universal Technician are certified to do what? - ANSWER Maintain, service, repair, or dispose of low-pressure appliances. Most low pressure appliances are used for what? - ANSWER Most low pressure appliances are used for comfort cooling and are subject to lower allowable ...

View example

EPA SECTION 608 TYPE III| 25 Questions | Correct Answers

(0)
$11.49

Which of the following refrigerants has a safety classification of B-1 - ANSWER HCFC-123 (R-123) The EPA-required evacuation level for recovery or recycling equipment used on low-pressure systems is - ANSWER 25 mm of Hg absolute. Which organization establishes the refrigerant safety grou...

View example

EPA 608 Certification Correct Questions & Answers

(0)
$10.99

What date was the sale of CFC's & HCFC's restricted to technicians certified in refrigerant recovery? - ANSWER November 14, 1994 Section 608 of the Federal Clean Air Act requires technicians to what? - ANSWER Recover all refrigerants. The objective of the Clean Air Act is to protect what? - ...

View example
Show all
avatar-seller
papersmaster01

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller papersmaster01. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $30.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

67096 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$231.29 $30.99
  • (0)
  Add to cart