[Show more]When a properly maintained, automatic sprinklers have proved to be 
the most effective means or protecting life and property 
 
 
 
Each normal sprinkler head flowing a 50psi will deliver about 
40 gpm 
 
 
 
 
Brainpower 
Read More 
Previous 
Play 
Next 
Rewind 10 seconds 
Move forward 10 seconds 
...
Preview 1 out of 4 pages
Add to cartWhen a properly maintained, automatic sprinklers have proved to be 
the most effective means or protecting life and property 
 
 
 
Each normal sprinkler head flowing a 50psi will deliver about 
40 gpm 
 
 
 
 
Brainpower 
Read More 
Previous 
Play 
Next 
Rewind 10 seconds 
Move forward 10 seconds 
...
SPRINKLER ARE DESIGNED AS 
FIRST LINE OF DEFENSE FOR A BUILDING 
 
 
 
THE TYPER OF SYSTEM AND THE SPACING OF THE DISCHARGE HEADS DEPENDS UPON THE TYPE OF ________________AND ____________________. 
OCCUPANCY AND WHAT IS BEING PROTECTED 
 
 
 
 
Brainpower 
Read More 
Previous 
Play 
Next 
Rewind 10 ...
Preview 1 out of 3 pages
Add to cartSPRINKLER ARE DESIGNED AS 
FIRST LINE OF DEFENSE FOR A BUILDING 
 
 
 
THE TYPER OF SYSTEM AND THE SPACING OF THE DISCHARGE HEADS DEPENDS UPON THE TYPE OF ________________AND ____________________. 
OCCUPANCY AND WHAT IS BEING PROTECTED 
 
 
 
 
Brainpower 
Read More 
Previous 
Play 
Next 
Rewind 10 ...
Greater than 95%of all fires are controlled by one or two sprinkler heads, and an even larger % of responses involve no fire at all but are minor malfunctions such as pressure surges or low air pressure in dry-pipe valves. 
 
 
 
If the building is built with an automatic wet sprinkler system, many ...
Preview 1 out of 3 pages
Add to cartGreater than 95%of all fires are controlled by one or two sprinkler heads, and an even larger % of responses involve no fire at all but are minor malfunctions such as pressure surges or low air pressure in dry-pipe valves. 
 
 
 
If the building is built with an automatic wet sprinkler system, many ...
ACTUATE 
To set into operation, especially an installed fire protection system. 
 
 
 
AUTOMATIC ALARM 
An alarm actuated by heat, smoke, flame-sensing devices, or the water flow in a sprinkler system conveyed to local alarm bells and/or the fire station. Also applies to boxes that automatically tra...
Preview 1 out of 3 pages
Add to cartACTUATE 
To set into operation, especially an installed fire protection system. 
 
 
 
AUTOMATIC ALARM 
An alarm actuated by heat, smoke, flame-sensing devices, or the water flow in a sprinkler system conveyed to local alarm bells and/or the fire station. Also applies to boxes that automatically tra...
Automatic Standpipe System 
A standpipe system that is attached to a water supply capable of supplying the system demand at all times and that requires no action other than opening a hose valve to provide water at hose connections. 
 
 
 
Churning 
A condition in a centrifugal in which the impeller ...
Preview 2 out of 10 pages
Add to cartAutomatic Standpipe System 
A standpipe system that is attached to a water supply capable of supplying the system demand at all times and that requires no action other than opening a hose valve to provide water at hose connections. 
 
 
 
Churning 
A condition in a centrifugal in which the impeller ...
Automatic Standpipe System 
A standpipe system that is attached to a water supply capable of supplying the system demand at all times and that requires no action other than opening a hose valve to provide water at hose connections. 
 
 
 
Auxiliary water supply 
supplementary source of water for a s...
Preview 2 out of 10 pages
Add to cartAutomatic Standpipe System 
A standpipe system that is attached to a water supply capable of supplying the system demand at all times and that requires no action other than opening a hose valve to provide water at hose connections. 
 
 
 
Auxiliary water supply 
supplementary source of water for a s...
What is the maximum pressure at the top-floor outlets when a booster pump is in place? 
65 psi 
 
 
 
How much air pressure is used to hold back the top part of the clapper in a differential dry-pipe valve? 
35 psi 
 
 
 
 
Brainpower 
Read More 
Previous 
Play 
Next 
Rewind 10 seconds 
Move forward...
Preview 2 out of 7 pages
Add to cartWhat is the maximum pressure at the top-floor outlets when a booster pump is in place? 
65 psi 
 
 
 
How much air pressure is used to hold back the top part of the clapper in a differential dry-pipe valve? 
35 psi 
 
 
 
 
Brainpower 
Read More 
Previous 
Play 
Next 
Rewind 10 seconds 
Move forward...
THE __________ IS RESPONSIBLE TO MAINTAIN SPRINKLER SYS. AND TO DETERMINE QUALIFICATIONS. 
OWNER 
 
 
 
RECORDS OF ALL INSPECTIONS AND MX SHALL BE MAINTAINED ON PREMISES FOR A MIN. OF __________ YEARS. 
3 
 
 
 
 
Brainpower 
Read More 
Previous 
Play 
Next 
Rewind 10 seconds 
Move forward 10 second...
Preview 3 out of 19 pages
Add to cartTHE __________ IS RESPONSIBLE TO MAINTAIN SPRINKLER SYS. AND TO DETERMINE QUALIFICATIONS. 
OWNER 
 
 
 
RECORDS OF ALL INSPECTIONS AND MX SHALL BE MAINTAINED ON PREMISES FOR A MIN. OF __________ YEARS. 
3 
 
 
 
 
Brainpower 
Read More 
Previous 
Play 
Next 
Rewind 10 seconds 
Move forward 10 second...
Which type of standpipe is intended for fire department use only? 
I 
 
 
 
Which type of heat detector must be replaced after activation? 
Fixed temperature 
 
 
 
 
Brainpower 
Read More 
Previous 
Play 
Next 
Rewind 10 seconds 
Move forward 10 seconds 
Unmute 
0:03 
/ 
0:15 
Full screen 
A fire d...
Preview 1 out of 2 pages
Add to cartWhich type of standpipe is intended for fire department use only? 
I 
 
 
 
Which type of heat detector must be replaced after activation? 
Fixed temperature 
 
 
 
 
Brainpower 
Read More 
Previous 
Play 
Next 
Rewind 10 seconds 
Move forward 10 seconds 
Unmute 
0:03 
/ 
0:15 
Full screen 
A fire d...
A _____ lined hose must be installed into hose cabinets, must not exceed 100 feet in length, and may be collapsible or noncollapsible. 
 
Select one: A. 2½-inch 
B. 1½-inch 
C. 1¾-inch 
D. 2-inch 
B. 1½-inch 
 
 
 
According to NFPA 14, a fire department connection must be located a minimum of _...
Preview 3 out of 19 pages
Add to cartA _____ lined hose must be installed into hose cabinets, must not exceed 100 feet in length, and may be collapsible or noncollapsible. 
 
Select one: A. 2½-inch 
B. 1½-inch 
C. 1¾-inch 
D. 2-inch 
B. 1½-inch 
 
 
 
According to NFPA 14, a fire department connection must be located a minimum of _...
In a preaction sprinkler system, what must happen before water will flow? 
Select one: 
A. The alarm condition must persist for a set time 
B. An alarm initiating device must be activated 
C. The dry-pipe valve must close 
D. System water pressure must drop 
B. An alarm initiating device must be act...
Preview 4 out of 45 pages
Add to cartIn a preaction sprinkler system, what must happen before water will flow? 
Select one: 
A. The alarm condition must persist for a set time 
B. An alarm initiating device must be activated 
C. The dry-pipe valve must close 
D. System water pressure must drop 
B. An alarm initiating device must be act...
Under normal circumstances, the air pressure gauge on a dry-pipe sprinkler system will read ________ the water pressure 
Lower than 
 
 
 
Which statement regarding a Class 1 standpipe system is correct? 
It is designed for use by the fire department 
 
 
 
 
Brainpower 
Read More 
Previous 
Play 
N...
Preview 1 out of 4 pages
Add to cartUnder normal circumstances, the air pressure gauge on a dry-pipe sprinkler system will read ________ the water pressure 
Lower than 
 
 
 
Which statement regarding a Class 1 standpipe system is correct? 
It is designed for use by the fire department 
 
 
 
 
Brainpower 
Read More 
Previous 
Play 
N...
High-rises and Standpipes SD test questions and answers.
Preview 1 out of 4 pages
Add to cartHigh-rises and Standpipes SD test questions and answers.
Which condition should be pointed out to occupants during a fire safety survey? 979 
a. Type 2 construction 
b. Void spaces in the attic 
c. Nonworking smoke detectors 
d. Presence of photovoltaic panels 
c. Nonworking smoke detectors 
 
 
 
On a preincident survey sketch or map, the locations of al...
Preview 3 out of 23 pages
Add to cartWhich condition should be pointed out to occupants during a fire safety survey? 979 
a. Type 2 construction 
b. Void spaces in the attic 
c. Nonworking smoke detectors 
d. Presence of photovoltaic panels 
c. Nonworking smoke detectors 
 
 
 
On a preincident survey sketch or map, the locations of al...
Chapter 22 Community Risk Reduction test questions and answers.
Preview 2 out of 15 pages
Add to cartChapter 22 Community Risk Reduction test questions and answers.
Passive fire protection 
In building involves constructing walls, floors, ceilings, beams, columns and shaft enclosures so that they can resist, control, and contain the damaging effects of a fire. 
 
 
 
Active Fire Protection System 
Systems include standpipe and sprinkler designed to detect, exti...
Preview 2 out of 5 pages
Add to cartPassive fire protection 
In building involves constructing walls, floors, ceilings, beams, columns and shaft enclosures so that they can resist, control, and contain the damaging effects of a fire. 
 
 
 
Active Fire Protection System 
Systems include standpipe and sprinkler designed to detect, exti...
fire department connection 
normally on exterior of building... FDNY can pump supplemental water into the sprinkler system, standpipe, or other system furnishing water for fire extinguishment to supplement existing water supplies. 
 
 
 
system control valve 
valve controlling flow to water-based fi...
Preview 4 out of 38 pages
Add to cartfire department connection 
normally on exterior of building... FDNY can pump supplemental water into the sprinkler system, standpipe, or other system furnishing water for fire extinguishment to supplement existing water supplies. 
 
 
 
system control valve 
valve controlling flow to water-based fi...
The automatic water supply for a sprinkler system is designed to supply: 
a. a majority of the fire sprinklers at any given time. 
b. only a fraction of total fire sprinklers at any given time. 
c. all of the fire sprinklers at any given time. 
d. only one fire sprinkler at any given time. 
b. only ...
Preview 2 out of 14 pages
Add to cartThe automatic water supply for a sprinkler system is designed to supply: 
a. a majority of the fire sprinklers at any given time. 
b. only a fraction of total fire sprinklers at any given time. 
c. all of the fire sprinklers at any given time. 
d. only one fire sprinkler at any given time. 
b. only ...
"Fail Safe" when referred to in locks, means 
that the door can be opened if the power fails 
 
 
 
Where does the on-duty Building Evacuation Supervisor report when an alarm is activated? 
To the Fire Command Station ( To act as Fire Safety Director when the FSD or a Deputy FSD is not required to...
Preview 2 out of 8 pages
Add to cart"Fail Safe" when referred to in locks, means 
that the door can be opened if the power fails 
 
 
 
Where does the on-duty Building Evacuation Supervisor report when an alarm is activated? 
To the Fire Command Station ( To act as Fire Safety Director when the FSD or a Deputy FSD is not required to...
How often shall the stem of an OS&Y Valve be lubricated 
Annually 
 
 
 
The 3 year dry pipe trip test is to be performed by whom? 
MP & MFSPC 
 
 
 
 
Brainpower 
Read More 
Previous 
Play 
Next 
Rewind 10 seconds 
Move forward 10 seconds 
Unmute 
0:01 
/ 
0:15 
Full screen 
Fire department connect...
Preview 2 out of 11 pages
Add to cartHow often shall the stem of an OS&Y Valve be lubricated 
Annually 
 
 
 
The 3 year dry pipe trip test is to be performed by whom? 
MP & MFSPC 
 
 
 
 
Brainpower 
Read More 
Previous 
Play 
Next 
Rewind 10 seconds 
Move forward 10 seconds 
Unmute 
0:01 
/ 
0:15 
Full screen 
Fire department connect...
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Stuvia is a marketplace, so you are not buying this document from us, but from seller GUARANTEEDSUCCESS. Stuvia facilitates payment to the seller.
No, you only buy these notes for $45.49. You're not tied to anything after your purchase.
4.6 stars on Google & Trustpilot (+1000 reviews)
62890 documents were sold in the last 30 days
Founded in 2010, the go-to place to buy study notes for 14 years now