[Montrer plus]How long does an owner have to fix a significant violation that does not pose an imminent threat to 
human health and safety or environment before being issued a red tag? 
a) 24 hours 
b) 48 hours 
c) 7 days 
d) 30 days - c) 7 days; CCR 2717.1(b) 
Which one of the following can perform ELD? 
a) lice...
Aperçu 2 sur 9 pages
Ajouter au panierHow long does an owner have to fix a significant violation that does not pose an imminent threat to 
human health and safety or environment before being issued a red tag? 
a) 24 hours 
b) 48 hours 
c) 7 days 
d) 30 days - c) 7 days; CCR 2717.1(b) 
Which one of the following can perform ELD? 
a) lice...
Type A Fire Extinguisher - Puts out paper, wood, cloth, rubbish fires. 
Type B Fire Extinguisher - Puts out flammable and combustible liquids. 
Type C Fire Extinguisher - Puts out electrical fires. 
According to CCR, Title 23 UST Regulations, what is the frequency that the monitor system certificati...
Aperçu 2 sur 10 pages
Ajouter au panierType A Fire Extinguisher - Puts out paper, wood, cloth, rubbish fires. 
Type B Fire Extinguisher - Puts out flammable and combustible liquids. 
Type C Fire Extinguisher - Puts out electrical fires. 
According to CCR, Title 23 UST Regulations, what is the frequency that the monitor system certificati...
Corrosion Specialist - designs and certifies cathodic protection system 
Secondary containment shall be constructed to contain at least the following volumes: - A. 100% of 
usable capacity of primary where there is only one primary is within the secondary 
B. 150% of the largest container if there a...
Aperçu 1 sur 4 pages
Ajouter au panierCorrosion Specialist - designs and certifies cathodic protection system 
Secondary containment shall be constructed to contain at least the following volumes: - A. 100% of 
usable capacity of primary where there is only one primary is within the secondary 
B. 150% of the largest container if there a...
Is this statement true or false? Fiberglass and flexible plastic piping do not need to have cathodic 
protection. - False. 
Cathodic protection - a technique used to control the corrosion of a metal surface by making it the 
cathode of an electrochemical cell. A simple method of protection connects ...
Aperçu 2 sur 10 pages
Ajouter au panierIs this statement true or false? Fiberglass and flexible plastic piping do not need to have cathodic 
protection. - False. 
Cathodic protection - a technique used to control the corrosion of a metal surface by making it the 
cathode of an electrochemical cell. A simple method of protection connects ...
1. One of the significant causes of leaks in underground liquid storage systems is ____________ 
________________ - Improper Installation 
2. Written Plans are required to - obtain permits, solicit bids, and provide precise guidance for 
installers. 
3. The plans should - Describe the property, iden...
Aperçu 3 sur 21 pages
Ajouter au panier1. One of the significant causes of leaks in underground liquid storage systems is ____________ 
________________ - Improper Installation 
2. Written Plans are required to - obtain permits, solicit bids, and provide precise guidance for 
installers. 
3. The plans should - Describe the property, iden...
What is the hold time for soil and preserved GW GRO samples? - 14 days 
Is an ICC certification needed to install an AST? - No 
Flammability limits of gasoline - 1.4 to 7.6% 
How many days do you have from a tank closure to report/provide the UST checklist to ECY? - 30 
days 
MTCA Method A lead CUL,...
Aperçu 2 sur 7 pages
Ajouter au panierWhat is the hold time for soil and preserved GW GRO samples? - 14 days 
Is an ICC certification needed to install an AST? - No 
Flammability limits of gasoline - 1.4 to 7.6% 
How many days do you have from a tank closure to report/provide the UST checklist to ECY? - 30 
days 
MTCA Method A lead CUL,...
Secondary containment required for all new USTs (date) - January 1, 1984 
(25291; H&SC) 
23 CCR closure requirements do not apply to UST closed prior to ____________________ (date) - 
January 1, 1984 
(2670(I); CCR) 
New UST with pressured piping must have secondary containment after _______________...
Aperçu 2 sur 8 pages
Ajouter au panierSecondary containment required for all new USTs (date) - January 1, 1984 
(25291; H&SC) 
23 CCR closure requirements do not apply to UST closed prior to ____________________ (date) - 
January 1, 1984 
(2670(I); CCR) 
New UST with pressured piping must have secondary containment after _______________...
Les clients de Stuvia ont évalués plus de 700 000 résumés. C'est comme ça que vous savez que vous achetez les meilleurs documents.
Vous pouvez payer rapidement avec iDeal, carte de crédit ou Stuvia-crédit pour les résumés. Il n'y a pas d'adhésion nécessaire.
Vos camarades écrivent eux-mêmes les notes d’étude, c’est pourquoi les documents sont toujours fiables et à jour. Cela garantit que vous arrivez rapidement au coeur du matériel.
Vous obtenez un PDF, disponible immédiatement après votre achat. Le document acheté est accessible à tout moment, n'importe où et indéfiniment via votre profil.
Notre garantie de satisfaction garantit que vous trouverez toujours un document d'étude qui vous convient. Vous remplissez un formulaire et notre équipe du service client s'occupe du reste.
Stuvia est une place de marché. Alors, vous n'achetez donc pas ce document chez nous, mais auprès du vendeur VasilyKichigin. Stuvia facilite les paiements au vendeur.
Non, vous n'achetez ce résumé que pour $35.99. Vous n'êtes lié à rien après votre achat.
4.6 étoiles sur Google & Trustpilot (+1000 avis)
63950 résumés ont été vendus ces 30 derniers jours
Fondée en 2010, la référence pour acheter des résumés depuis déjà 15 ans