Minnesota Special Boiler License Exam Package Deal
Minnesota Special Boiler License Exam Package Deal
[Show more]Minnesota Special Boiler License Exam Package Deal
[Show more]MN Boiler License Questions and Answers with Complete Solution 
 
a question - an answer 
 
what are the conditions necessary for good combustion? 
a) low sulfur content 
b) Thermal, thermocoupler, tubular 
c) turbulence, temperature, time 3T's - c) turbulence, temperature, time 3T's 
 
why is se...
Preview 4 out of 36 pages
Add to cartMN Boiler License Questions and Answers with Complete Solution 
 
a question - an answer 
 
what are the conditions necessary for good combustion? 
a) low sulfur content 
b) Thermal, thermocoupler, tubular 
c) turbulence, temperature, time 3T's - c) turbulence, temperature, time 3T's 
 
why is se...
MN Boiler Exam with absolute solution 
 
Cast Iron Sectional Boiler - Like Bread, sections in between are intermediate. 
Held together with push nipples and stay bolts. 
No special foundation required 
Expandable (can add more centers to increase heating capacity) 
Boiler trim mounted on end section...
Preview 2 out of 13 pages
Add to cartMN Boiler Exam with absolute solution 
 
Cast Iron Sectional Boiler - Like Bread, sections in between are intermediate. 
Held together with push nipples and stay bolts. 
No special foundation required 
Expandable (can add more centers to increase heating capacity) 
Boiler trim mounted on end section...
Minnesota Special Engineer Boiler License Practice Exam Questions and Answers Verified 100% 
 
For the purpose of rating boiler horsepower for an Engineers License only, how many square feet of boiler surface shall be equivalent to one boiler horsepower on a boiler? - 10 Sq. Ft. Heating Surface 
 
W...
Preview 1 out of 4 pages
Add to cartMinnesota Special Engineer Boiler License Practice Exam Questions and Answers Verified 100% 
 
For the purpose of rating boiler horsepower for an Engineers License only, how many square feet of boiler surface shall be equivalent to one boiler horsepower on a boiler? - 10 Sq. Ft. Heating Surface 
 
W...
Minnesota Special Boiler License Practice Exam Q&A Latest Updates 
 
How many way can heat be transferred? - Three (Conduction -- Convection -- Radiation) 
 
How may types of low pressure are there? - Three 
 
Boiler and boiler fitting used in the state of Minnesota must be constructed to what code?...
Preview 2 out of 5 pages
Add to cartMinnesota Special Boiler License Practice Exam Q&A Latest Updates 
 
How many way can heat be transferred? - Three (Conduction -- Convection -- Radiation) 
 
How may types of low pressure are there? - Three 
 
Boiler and boiler fitting used in the state of Minnesota must be constructed to what code?...
MN Boiler License Questions with Accurately Solved Answers 100% 
 
what are the conditions necessary for good combustion? 
a) low sulfur content 
b) Thermal, thermocoupler, tubular 
c) turbulence, temperature, time (three T's) - c) turbulence, temperature, time (three T's) 
 
why is secondary air...
Preview 3 out of 22 pages
Add to cartMN Boiler License Questions with Accurately Solved Answers 100% 
 
what are the conditions necessary for good combustion? 
a) low sulfur content 
b) Thermal, thermocoupler, tubular 
c) turbulence, temperature, time (three T's) - c) turbulence, temperature, time (three T's) 
 
why is secondary air...
MN Boiler license Exam Questions and Answers Graded A+ 
 
What is the unit called that controls starting and stopping of the burner by sensing temperature of water in a hot water boiler? - Aquastat 
 
What controls the temperature of the water in a hot water boiler system? - Aquastat or remote tempe...
Preview 2 out of 9 pages
Add to cartMN Boiler license Exam Questions and Answers Graded A+ 
 
What is the unit called that controls starting and stopping of the burner by sensing temperature of water in a hot water boiler? - Aquastat 
 
What controls the temperature of the water in a hot water boiler system? - Aquastat or remote tempe...
Minnesota Second Class Boiler Licenses Study Guide 
 
Certificate of inspection - means a sticker attached to the boiler or pressure vessel which documents the month and year of the inspection and the employer of the inspector performing the inspection. 
 
Certificate of registration - means a docum...
Preview 2 out of 6 pages
Add to cartMinnesota Second Class Boiler Licenses Study Guide 
 
Certificate of inspection - means a sticker attached to the boiler or pressure vessel which documents the month and year of the inspection and the employer of the inspector performing the inspection. 
 
Certificate of registration - means a docum...
Boiler License Test Latest Updates 
 
Natural draft is produced by? - difference in temperature outside chimney from inside chimney 
 
If a draft fan is located between the boiler and chimney, what type of draft system is it? - Induced draft 
 
boiler fittings are important for: - safety only 
 
the...
Preview 1 out of 4 pages
Add to cartBoiler License Test Latest Updates 
 
Natural draft is produced by? - difference in temperature outside chimney from inside chimney 
 
If a draft fan is located between the boiler and chimney, what type of draft system is it? - Induced draft 
 
boiler fittings are important for: - safety only 
 
the...
Minnesota Boiler Operator Licensing Exam A Score 
 
1 or more safety valves - all steam boilers must have 
 
Locked closed - before anyone enters the boiler drum, the main steam stop valve, bottom blowdown valves, & feedwater valves should be 
 
212 degrees F - at atmospheric pressure, water begins ...
Preview 2 out of 7 pages
Add to cartMinnesota Boiler Operator Licensing Exam A Score 
 
1 or more safety valves - all steam boilers must have 
 
Locked closed - before anyone enters the boiler drum, the main steam stop valve, bottom blowdown valves, & feedwater valves should be 
 
212 degrees F - at atmospheric pressure, water begins ...
MN Special Boilers License Preparation Test Latest 
 
Special (License Grade) - Work in any type of plant 
 
Grade C (License Grade) - Can operate low-pressure steam or hot water (no steam engines/turbines) 
 
Grade B (License Grade) - Can operate high-pressure or low-pressure steam or hot water (no...
Preview 2 out of 12 pages
Add to cartMN Special Boilers License Preparation Test Latest 
 
Special (License Grade) - Work in any type of plant 
 
Grade C (License Grade) - Can operate low-pressure steam or hot water (no steam engines/turbines) 
 
Grade B (License Grade) - Can operate high-pressure or low-pressure steam or hot water (no...
MN Special Engineers Practice Exam Q&A Recently Updated 
 
for the purpose of rating boiler horsepower for an Engineers licence only, how many square feet of boiler surface shall be equivalent to one boiler horsepower on a boiler? - 10 Sq. Ft. Heating Surface 
 
What is meant by the term Low Pressur...
Preview 1 out of 4 pages
Add to cartMN Special Engineers Practice Exam Q&A Recently Updated 
 
for the purpose of rating boiler horsepower for an Engineers licence only, how many square feet of boiler surface shall be equivalent to one boiler horsepower on a boiler? - 10 Sq. Ft. Heating Surface 
 
What is meant by the term Low Pressur...
MN State Special Boiler License Study Guide 
 
ASME - American Society of Mechanical Engineers 
 
NBIC - National Board Inspection Code 
 
A high-pressure steam boiler is required to have ______ valves on the main steam line. - 2 
 
10 square feet is equivalent to _____ boiler horsepower for conven...
Preview 2 out of 5 pages
Add to cartMN State Special Boiler License Study Guide 
 
ASME - American Society of Mechanical Engineers 
 
NBIC - National Board Inspection Code 
 
A high-pressure steam boiler is required to have ______ valves on the main steam line. - 2 
 
10 square feet is equivalent to _____ boiler horsepower for conven...
Boiler Operators Exam Correctly Solved 
 
At 0 pounds per square inch (psi), how many Btu are necessary to change 1 lb of water at 212 degree Fahrenheit into 1 lb of STEAM - 970 Btu 
 
What is Radiation? - A form of heat transfer by waves 
 
What is Superheated steam? - Steam at 100 psi and at 400 F...
Preview 2 out of 13 pages
Add to cartBoiler Operators Exam Correctly Solved 
 
At 0 pounds per square inch (psi), how many Btu are necessary to change 1 lb of water at 212 degree Fahrenheit into 1 lb of STEAM - 970 Btu 
 
What is Radiation? - A form of heat transfer by waves 
 
What is Superheated steam? - Steam at 100 psi and at 400 F...
MN Special Boilers Licensing Test 2024 
 
The number of blowdowns required is determined by_____________. - boiler water analysis 
 
A ____________ pump is a boiler accessory used to draw condensate back from the system by producing a negative pressure on the condensate return lines. - vacuum 
 
Oxy...
Preview 1 out of 4 pages
Add to cartMN Special Boilers Licensing Test 2024 
 
The number of blowdowns required is determined by_____________. - boiler water analysis 
 
A ____________ pump is a boiler accessory used to draw condensate back from the system by producing a negative pressure on the condensate return lines. - vacuum 
 
Oxy...
Minnesota Boilers Final Exam with Complete Solution 
 
For the purpose of rating boiler horsepower for an Engineer's License only, what should be equivalent to one boiler horsepower on a boiler? - 10 sq. ft. heating surface or 67,000 but input 
 
What is the most important valve on the boiler? - Sa...
Preview 2 out of 7 pages
Add to cartMinnesota Boilers Final Exam with Complete Solution 
 
For the purpose of rating boiler horsepower for an Engineer's License only, what should be equivalent to one boiler horsepower on a boiler? - 10 sq. ft. heating surface or 67,000 but input 
 
What is the most important valve on the boiler? - Sa...
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Stuvia is a marketplace, so you are not buying this document from us, but from seller Academicmines. Stuvia facilitates payment to the seller.
No, you only buy these notes for $34.99. You're not tied to anything after your purchase.
4.6 stars on Google & Trustpilot (+1000 reviews)
72042 documents were sold in the last 30 days
Founded in 2010, the go-to place to buy study notes for 14 years now