Package deal
Package deal for Stationary Engineering Exam Questions with 100% Correct Answers
Package deal for Stationary Engineering Exam Questions with 100% Correct Answers
[Show more]Package deal for Stationary Engineering Exam Questions with 100% Correct Answers
[Show more]Stationary Engineer Exam Questions And 
Answers 100% Solved 
How much clearance from the top of the boiler is needed for a HP boiler that produces 70000 lbs 
of steam? - answer7 feet 
On a gas fired boiler what is the proper gas to air mixture - answer30%-70% and in special 
arrangements it can be a...
Preview 4 out of 35 pages
Add to cartStationary Engineer Exam Questions And 
Answers 100% Solved 
How much clearance from the top of the boiler is needed for a HP boiler that produces 70000 lbs 
of steam? - answer7 feet 
On a gas fired boiler what is the proper gas to air mixture - answer30%-70% and in special 
arrangements it can be a...
upStationary Grade 3 Engineering License 
Exam Questions And Answers 100% Solved 
how can you loose your license? - answer1) drinking on the job 
2) sleeping on the job 
3) negligence 
4) unsafe work 
5) signing a falsified license application for someone 
6) failing to renew your license annually 
...
Preview 4 out of 70 pages
Add to cartupStationary Grade 3 Engineering License 
Exam Questions And Answers 100% Solved 
how can you loose your license? - answer1) drinking on the job 
2) sleeping on the job 
3) negligence 
4) unsafe work 
5) signing a falsified license application for someone 
6) failing to renew your license annually 
...
1st Class Stationary Engineers Examination 
Questions And Answers 100% Solved 
Deaerator - answerA Device used to remove oxygen from boiler feedwater 
The term "quality of steam" has to do with steams - answerMoisture content 
A sleeve is used on the shaft of a centrifugal pump to - answerProtect ...
Preview 2 out of 6 pages
Add to cart1st Class Stationary Engineers Examination 
Questions And Answers 100% Solved 
Deaerator - answerA Device used to remove oxygen from boiler feedwater 
The term "quality of steam" has to do with steams - answerMoisture content 
A sleeve is used on the shaft of a centrifugal pump to - answerProtect ...
1st Class Stationary Engineers Examination 
Questions And Answers 100% Solved 
when is it best to replace the manhole gasket - answereach year after cleaning the inside of 
the boiler 
When riveting boiler plate it is most important to - answerget the proper pitch between the 
rivets 
A vapor heatin...
Preview 1 out of 2 pages
Add to cart1st Class Stationary Engineers Examination 
Questions And Answers 100% Solved 
when is it best to replace the manhole gasket - answereach year after cleaning the inside of 
the boiler 
When riveting boiler plate it is most important to - answerget the proper pitch between the 
rivets 
A vapor heatin...
Stationary Engineer Exam Questions And 
Answers 100% Solved 
What is a water tube boiler? What are five of the advantages & disadvantages of a water tube 
boiler? Name four types of water tube boilers. - answerIn a water tube boiler the products of 
combustion pass around the 
tubes containing boile...
Preview 2 out of 15 pages
Add to cartStationary Engineer Exam Questions And 
Answers 100% Solved 
What is a water tube boiler? What are five of the advantages & disadvantages of a water tube 
boiler? Name four types of water tube boilers. - answerIn a water tube boiler the products of 
combustion pass around the 
tubes containing boile...
Stationary Engineer Electric Exam Questions 
With 100% Correct Answers 
An AC circuit consists only of a pure inductance and a power source. The relationship between 
the voltage and the current in this circuit is that the - answercurrent lags the voltage 
The power factor of a load is equal to the ...
Preview 3 out of 26 pages
Add to cartStationary Engineer Electric Exam Questions 
With 100% Correct Answers 
An AC circuit consists only of a pure inductance and a power source. The relationship between 
the voltage and the current in this circuit is that the - answercurrent lags the voltage 
The power factor of a load is equal to the ...
Stationary Engineering Exam Questions And 
Answers 100% Solved 
The Main function of a steam separator in a steam power plant is to - answerincrease steam 
quality 
The MAIN purpose of a dip tube in a low-pressure hot water system is to - answerprevent air 
from entering the main 
The rating of a un...
Preview 2 out of 6 pages
Add to cartStationary Engineering Exam Questions And 
Answers 100% Solved 
The Main function of a steam separator in a steam power plant is to - answerincrease steam 
quality 
The MAIN purpose of a dip tube in a low-pressure hot water system is to - answerprevent air 
from entering the main 
The rating of a un...
Stationary Engineering Test Exam 
Questions And Answers 100% Solved 
When designing a boiler, special consideration must be given to heat transmission - 
answerRadiation, conduction, and convection 
Which type of heat transfer takes place by actual physical contact, from molecule to molecule, 
witho...
Preview 2 out of 14 pages
Add to cartStationary Engineering Test Exam 
Questions And Answers 100% Solved 
When designing a boiler, special consideration must be given to heat transmission - 
answerRadiation, conduction, and convection 
Which type of heat transfer takes place by actual physical contact, from molecule to molecule, 
witho...
Stationary Engineer License Exam Prep 
Questions And Answers 100% Solved 
A ______ fuse is necessary for a circuit with a load of 21,000 watts and a voltage 
of 220 volts. 
A. 100 
B. 150 
C. 175 
D. 200 
A. 100 amps. Note: V = IR Therefore I = V/R 21,000 amps /220 volts = 95 amps 
At 0 psig, how ma...
Preview 4 out of 68 pages
Add to cartStationary Engineer License Exam Prep 
Questions And Answers 100% Solved 
A ______ fuse is necessary for a circuit with a load of 21,000 watts and a voltage 
of 220 volts. 
A. 100 
B. 150 
C. 175 
D. 200 
A. 100 amps. Note: V = IR Therefore I = V/R 21,000 amps /220 volts = 95 amps 
At 0 psig, how ma...
Stationary Engineering Chapter 1 Exam 
___ is a pushing or pulling motion and is commonly measured in pounds. - answerForce 
The amount of work performed is the ___ of the force and distance moved. - answerproduct 
___ is the heat required to change the state of 1 lb of a substance from a solid to a...
Preview 1 out of 1 pages
Add to cartStationary Engineering Chapter 1 Exam 
___ is a pushing or pulling motion and is commonly measured in pounds. - answerForce 
The amount of work performed is the ___ of the force and distance moved. - answerproduct 
___ is the heat required to change the state of 1 lb of a substance from a solid to a...
Stationary engineering lic prep Exam 
Questions And Answers 
Wire drawing - answerDifference in pressure going from a large volume to a smaller volume 
Continuous blowdown - answerUsed for the removal of surface impurities on the boilers 
water surface 
Why are stays used on flat surfaces not round?...
Preview 2 out of 5 pages
Add to cartStationary engineering lic prep Exam 
Questions And Answers 
Wire drawing - answerDifference in pressure going from a large volume to a smaller volume 
Continuous blowdown - answerUsed for the removal of surface impurities on the boilers 
water surface 
Why are stays used on flat surfaces not round?...
Stationary Engineering Exam Questions And 
Answers 100% Solved 
In a reciprocating feedwater pump, the _______________ 
A. water piston is larger than the steam piston 
B. water and steam piston are the same size 
C. steam piston is larger than the water piston 
D. steam valve has to be as large as ...
Preview 4 out of 37 pages
Add to cartStationary Engineering Exam Questions And 
Answers 100% Solved 
In a reciprocating feedwater pump, the _______________ 
A. water piston is larger than the steam piston 
B. water and steam piston are the same size 
C. steam piston is larger than the water piston 
D. steam valve has to be as large as ...
MD Stationary Engineer Exam Questions 
And Answers 
Gases of Combustion that cool on Contact with the boiler heating Surface before combushion is 
completed Cause a(n) _________ - answerFormation of soot and smoke 
In the event of a flame failure, the programmer will______ - answerSecure the fuel, p...
Preview 1 out of 3 pages
Add to cartMD Stationary Engineer Exam Questions 
And Answers 
Gases of Combustion that cool on Contact with the boiler heating Surface before combushion is 
completed Cause a(n) _________ - answerFormation of soot and smoke 
In the event of a flame failure, the programmer will______ - answerSecure the fuel, p...
Stationary Engineering Exam Questions And 
Answers 100% Solved 
What is the pressure at the base of a vertical foot of water? - answer0.433 psi 
How much should the boiler pressure increase when performing a hydrostatic test? - 
answer1.5 times the safety valve setting 
The range of a boiler steam p...
Preview 2 out of 7 pages
Add to cartStationary Engineering Exam Questions And 
Answers 100% Solved 
What is the pressure at the base of a vertical foot of water? - answer0.433 psi 
How much should the boiler pressure increase when performing a hydrostatic test? - 
answer1.5 times the safety valve setting 
The range of a boiler steam p...
Stationary Engineering Exam Questions And 
Answers 100% Solved 
There must be adequate ___ across any steam trap for the condensate and/or air 
to be removed from the steam system. 
differential pressure 
When 200 lb of water is heated from 62°F to 75°F, ___ Btu is absorbed. 
2600 
A(n) ___ is use...
Preview 3 out of 16 pages
Add to cartStationary Engineering Exam Questions And 
Answers 100% Solved 
There must be adequate ___ across any steam trap for the condensate and/or air 
to be removed from the steam system. 
differential pressure 
When 200 lb of water is heated from 62°F to 75°F, ___ Btu is absorbed. 
2600 
A(n) ___ is use...
Stationary Engineering Exam Questions And 
Answers 100% Solved 
What is the pressure at the base of a vertical foot of water? - answer0.433 psi 
How much should the boiler pressure increase when performing a hydrostatic test? - 
answer1.5 times the safety valve setting 
The range of a boiler steam p...
Preview 2 out of 7 pages
Add to cartStationary Engineering Exam Questions And 
Answers 100% Solved 
What is the pressure at the base of a vertical foot of water? - answer0.433 psi 
How much should the boiler pressure increase when performing a hydrostatic test? - 
answer1.5 times the safety valve setting 
The range of a boiler steam p...
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Stuvia is a marketplace, so you are not buying this document from us, but from seller Brainbarter. Stuvia facilitates payment to the seller.
No, you only buy these notes for $39.49. You're not tied to anything after your purchase.
4.6 stars on Google & Trustpilot (+1000 reviews)
72042 documents were sold in the last 30 days
Founded in 2010, the go-to place to buy study notes for 14 years now