[Show more]Current flow is - ans-the flow of electrons in the circuit 
 
impedance is - ans-opposition to alternating current flow 
 
like charges - ans-repel each other 
 
Any material that will readily release electrons is called - ans-a conductor 
 
the symbol for current is - ans-I 
 
W...
Preview 2 out of 10 pages
Add to cartCurrent flow is - ans-the flow of electrons in the circuit 
 
impedance is - ans-opposition to alternating current flow 
 
like charges - ans-repel each other 
 
Any material that will readily release electrons is called - ans-a conductor 
 
the symbol for current is - ans-I 
 
W...
An instrument that measures potential differences between 2 points in an electrical circuit is called? 
 
A. potentiometer 
B. thermistor 
C. ohmeter 
D. voltmeter - ans-voltmeter 
 
This device uses a thermal sensing bulb at the outlet of the evaporator to sense temperature and control superhea...
Preview 3 out of 26 pages
Add to cartAn instrument that measures potential differences between 2 points in an electrical circuit is called? 
 
A. potentiometer 
B. thermistor 
C. ohmeter 
D. voltmeter - ans-voltmeter 
 
This device uses a thermal sensing bulb at the outlet of the evaporator to sense temperature and control superhea...
What is an SSU and what does it do? - ans-It is a unit located on the side of the first which receives power (120 volts) before anything located within the furnace itself. It primarily consists of a switch and a fuse, and it is what allows for power to flow to the door switch. Opening the switc...
Preview 1 out of 3 pages
Add to cartWhat is an SSU and what does it do? - ans-It is a unit located on the side of the first which receives power (120 volts) before anything located within the furnace itself. It primarily consists of a switch and a fuse, and it is what allows for power to flow to the door switch. Opening the switc...
What is current flow? - ans-D.The flow of electrons in a circuit 
 
What is impedance? - ans-A.Opposition to alternating current 
 
Like charges will - ans-B.Repel each other 
 
Any material that will readily release electrons is called: - ans-B.A conductor 
 
The symbol for curr...
Preview 2 out of 10 pages
Add to cartWhat is current flow? - ans-D.The flow of electrons in a circuit 
 
What is impedance? - ans-A.Opposition to alternating current 
 
Like charges will - ans-B.Repel each other 
 
Any material that will readily release electrons is called: - ans-B.A conductor 
 
The symbol for curr...
1. Heat which causes a change in temperature of a substance is called; 
A. latent heat 
B. sensible heat 
C. superheat 
D. radiant heat - ans-B. sensible heat 
 
2. Heat added to a substance without a raise in temperature; (example: liquid refrigerant to gas) this process is called? 
A. latent ...
Preview 3 out of 26 pages
Add to cart1. Heat which causes a change in temperature of a substance is called; 
A. latent heat 
B. sensible heat 
C. superheat 
D. radiant heat - ans-B. sensible heat 
 
2. Heat added to a substance without a raise in temperature; (example: liquid refrigerant to gas) this process is called? 
A. latent ...
A technician has found an air conditioning system with a leak in the liquid line. After the line is repaired, the system is evacuated and properly retired. When the system is started, the compressor is noisy and running hot. The most probable cause of the noise is.... - ans-Lower oil in the sys...
Preview 2 out of 6 pages
Add to cartA technician has found an air conditioning system with a leak in the liquid line. After the line is repaired, the system is evacuated and properly retired. When the system is started, the compressor is noisy and running hot. The most probable cause of the noise is.... - ans-Lower oil in the sys...
Heat which causes a change in temperature of a substance is called; - ans-sensible heat. 
 
Heat which causes a change in state of a material without a change in temperature is called; - ans-latent heat. 
 
Heat which is added to a vapor after the change of state occurs is called; - ans-...
Preview 2 out of 13 pages
Add to cartHeat which causes a change in temperature of a substance is called; - ans-sensible heat. 
 
Heat which causes a change in state of a material without a change in temperature is called; - ans-latent heat. 
 
Heat which is added to a vapor after the change of state occurs is called; - ans-...
1x sold
An air-to-air heat pump has many of the same components as an air conditioning system. The major difference is that a heat pump also has an - ans-Reversing valve 
 
What is the difference between "demand defrost" and "timed defrost"? - ans-Demand defrost happens only when needed and timed ...
Preview 2 out of 11 pages
Add to cartAn air-to-air heat pump has many of the same components as an air conditioning system. The major difference is that a heat pump also has an - ans-Reversing valve 
 
What is the difference between "demand defrost" and "timed defrost"? - ans-Demand defrost happens only when needed and timed ...
Heat which causes a change in temperature of a substance is called; - ans-Sensible Heat. 
 
heat added to substance without a rise in temperature; (example: liquid refrigerant to gas) this process is called? - ans-Latent heat of vaporization. 
 
Heat added to the refrigerant in a vapor state...
Preview 2 out of 10 pages
Add to cartHeat which causes a change in temperature of a substance is called; - ans-Sensible Heat. 
 
heat added to substance without a rise in temperature; (example: liquid refrigerant to gas) this process is called? - ans-Latent heat of vaporization. 
 
Heat added to the refrigerant in a vapor state...
1. A gas furnace is to be installed in a garage. The burners and ignition sources must be located ______ above the floor. 
A: 6 inches 
B: 12 inches 
C: 18 inches 
D: 24 inches - ans-C: 18 inches 
 
2. A good description of how hi-metai fan switch operates the blower motor on a gas furnace is: 
A...
Preview 3 out of 25 pages
Add to cart1. A gas furnace is to be installed in a garage. The burners and ignition sources must be located ______ above the floor. 
A: 6 inches 
B: 12 inches 
C: 18 inches 
D: 24 inches - ans-C: 18 inches 
 
2. A good description of how hi-metai fan switch operates the blower motor on a gas furnace is: 
A...
1x sold
Before working on an electric furnace the tech should - ans-Review diagram, remove jewelry, and follow safety procedures. ALL OF THE ABOVE. 
 
A GFCI circuit breaker - ans-detects current leaks to groound 
 
the conductor in an electric heat element is usually made of - ans-Nichrome 
 
A...
Preview 2 out of 10 pages
Add to cartBefore working on an electric furnace the tech should - ans-Review diagram, remove jewelry, and follow safety procedures. ALL OF THE ABOVE. 
 
A GFCI circuit breaker - ans-detects current leaks to groound 
 
the conductor in an electric heat element is usually made of - ans-Nichrome 
 
A...
A gas furnace is to be installed in a garage. The national standards require that the burners and ignition sources must be located ______ above the floor - ans-18 inches 
 
A good description of how a bi-metal fan switch operates the blower motor on a gas furnace is - ans-Temperature on- tempe...
Preview 2 out of 10 pages
Add to cartA gas furnace is to be installed in a garage. The national standards require that the burners and ignition sources must be located ______ above the floor - ans-18 inches 
 
A good description of how a bi-metal fan switch operates the blower motor on a gas furnace is - ans-Temperature on- tempe...
using an ohmmeter, there is 120 VAC between high speed and ground wires, this indicates - ans-open 
 
if temperature rise is too high... - ans-increase fan speed 
 
how many of the 3 OSHA conditions defining confined spaces must be met - ans-all 3 
 
what causes the temperature limit safety...
Preview 2 out of 7 pages
Add to cartusing an ohmmeter, there is 120 VAC between high speed and ground wires, this indicates - ans-open 
 
if temperature rise is too high... - ans-increase fan speed 
 
how many of the 3 OSHA conditions defining confined spaces must be met - ans-all 3 
 
what causes the temperature limit safety...
A room contains two fuel burning appliances. The total btu input of both appliances is 125,000 BTU's. How many cubic feet are required for the room NOT to be considered confined space? - ans-125,000/1000 = +50 6250 
 
What is the maximum length of the flexible gas connector going to a furnace? -...
Preview 2 out of 7 pages
Add to cartA room contains two fuel burning appliances. The total btu input of both appliances is 125,000 BTU's. How many cubic feet are required for the room NOT to be considered confined space? - ans-125,000/1000 = +50 6250 
 
What is the maximum length of the flexible gas connector going to a furnace? -...
Heat which causes a change in temperature of a substance is called - ans-Sensible Heat 
 
Heat added to a substance without a rise in temperature is called - ans-Latent Heat 
 
Heat added to refrigerant in a vapor state after the evaporation process is called - ans-Superheat 
 
A scroll com...
Preview 2 out of 10 pages
Add to cartHeat which causes a change in temperature of a substance is called - ans-Sensible Heat 
 
Heat added to a substance without a rise in temperature is called - ans-Latent Heat 
 
Heat added to refrigerant in a vapor state after the evaporation process is called - ans-Superheat 
 
A scroll com...
When a new system has been assembled, the first thing to do is? - ans-Pressurize the system with an inert gas & leak check. 
 
After installation of a field-piped R-410A split heat pulp, the unit should first be? - ans-Pressurized with nitrogen then leak checked. 
 
The EPA regulations requi...
Preview 2 out of 8 pages
Add to cartWhen a new system has been assembled, the first thing to do is? - ans-Pressurize the system with an inert gas & leak check. 
 
After installation of a field-piped R-410A split heat pulp, the unit should first be? - ans-Pressurized with nitrogen then leak checked. 
 
The EPA regulations requi...
Industrial process and refrigeration units with a 50 pound charge or more with an annualized leak rate of _____ or more must have leaks repaired. - ans-35% 
 
Unless plans are made to replace a system exceeding the maximum leak, repairs must be made in; - ans-30 days 
 
Refrigerants CFC R-12...
Preview 1 out of 3 pages
Add to cartIndustrial process and refrigeration units with a 50 pound charge or more with an annualized leak rate of _____ or more must have leaks repaired. - ans-35% 
 
Unless plans are made to replace a system exceeding the maximum leak, repairs must be made in; - ans-30 days 
 
Refrigerants CFC R-12...
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Stuvia is a marketplace, so you are not buying this document from us, but from seller Prose1. Stuvia facilitates payment to the seller.
No, you only buy these notes for $30.49. You're not tied to anything after your purchase.
4.6 stars on Google & Trustpilot (+1000 reviews)
62890 documents were sold in the last 30 days
Founded in 2010, the go-to place to buy study notes for 14 years now