maximum load that may be supplied by 20a, 120v circuit? - Ans: 20a x 120v = 2400va 
 
maximum load that may be supplied by 20a, 3 wire, 120/240v circuit? - Ans: 20a x 240v = 4800va 
 
maximum load that may be suppl...
Voorbeeld 3 van de 22 pagina's
In winkelwagenLoad Calculations Branch and Feeder Circuits Exam Questions and Complete Solutions 
 
maximum load that may be supplied by 20a, 120v circuit? - Ans: 20a x 120v = 2400va 
 
maximum load that may be supplied by 20a, 3 wire, 120/240v circuit? - Ans: 20a x 240v = 4800va 
 
maximum load that may be suppl...
Electrical-Level 3, Chapter 1 Exam Questions and Complete Solutions 
 
What is the total load, in VA, for two small appliance branch circuits in a single-family dwelling? - Ans: 3,000VA 
 
What is the maximum number of general-purpose noncontinuous duty duplex receptacles that can be connected to a ...
Voorbeeld 1 van de 4 pagina's
In winkelwagenElectrical-Level 3, Chapter 1 Exam Questions and Complete Solutions 
 
What is the total load, in VA, for two small appliance branch circuits in a single-family dwelling? - Ans: 3,000VA 
 
What is the maximum number of general-purpose noncontinuous duty duplex receptacles that can be connected to a ...
Electrical level 3 Mod 1 Exam Questions and Complete Solutions 
 
The purpose of branch circuit load calculations is to determine - Ans: The size of branch circuit overcurrent protection and branch circuit conductors using NEC 
 
NEC article 210 - Ans: Covers branch circuits ( except for branch circ...
Voorbeeld 1 van de 3 pagina's
In winkelwagenElectrical level 3 Mod 1 Exam Questions and Complete Solutions 
 
The purpose of branch circuit load calculations is to determine - Ans: The size of branch circuit overcurrent protection and branch circuit conductors using NEC 
 
NEC article 210 - Ans: Covers branch circuits ( except for branch circ...
Electricity Level 3, Section 1 Exam Questions and Complete Solutions 
 
What is the demand load for one household range with a nameplate rating of 11.75kW, 240V, 1○? - Ans: 8kW 
 
Air conditioning overcurrent protective devices can never exceed what percentage of the motor-rated load current or th...
Voorbeeld 1 van de 2 pagina's
In winkelwagenElectricity Level 3, Section 1 Exam Questions and Complete Solutions 
 
What is the demand load for one household range with a nameplate rating of 11.75kW, 240V, 1○? - Ans: 8kW 
 
Air conditioning overcurrent protective devices can never exceed what percentage of the motor-rated load current or th...
Electrical Level 3 Module 1 Load Calculations and Branch Feeder Circuits Exam Questions and Complete Solutions 
 
NEC 220.14 - each outlet has an assigned load of ___ - Ans: 180VA 
 
NEC Table 310.16 covers conductors rated up to ___ - Ans: 0-2000V 
 
NEC 220.14(I) each receptacle is assigned a valu...
Voorbeeld 2 van de 5 pagina's
In winkelwagenElectrical Level 3 Module 1 Load Calculations and Branch Feeder Circuits Exam Questions and Complete Solutions 
 
NEC 220.14 - each outlet has an assigned load of ___ - Ans: 180VA 
 
NEC Table 310.16 covers conductors rated up to ___ - Ans: 0-2000V 
 
NEC 220.14(I) each receptacle is assigned a valu...
Electrical-Level 3 Chapter 1 Exam Questions with Correct Answers 
 
What is the total load, in VA, for two small appliance branch circuits in a single-family dwelling? - Ans: 3,000VA 
 
What is the maximum number of general-purpose noncontinuous duty duplex receptacles that can be connected to a 20A...
Voorbeeld 1 van de 4 pagina's
In winkelwagenElectrical-Level 3 Chapter 1 Exam Questions with Correct Answers 
 
What is the total load, in VA, for two small appliance branch circuits in a single-family dwelling? - Ans: 3,000VA 
 
What is the maximum number of general-purpose noncontinuous duty duplex receptacles that can be connected to a 20A...
26301-17 Branch and Feeder Circuits Exam Questions and Complete Solutions 
 
what is the demand load for one household range with a nameplate rating of 11.75kW, 240V, 1 - Ans: 8kW 
 
air conditioning overcurrent protective devices can never exceed what percentage of the moror-rated load current or t...
Voorbeeld 1 van de 3 pagina's
In winkelwagen26301-17 Branch and Feeder Circuits Exam Questions and Complete Solutions 
 
what is the demand load for one household range with a nameplate rating of 11.75kW, 240V, 1 - Ans: 8kW 
 
air conditioning overcurrent protective devices can never exceed what percentage of the moror-rated load current or t...
Electrical Phase 3 Module 1 Exam Questions and Complete Solutions 
 
The ampacity of a conductor is defined by the NEC to be the current in amperes, a conductor can carry continuously under the conditions of use without exceeding ______. 
a) its temperature rating 
b) the allowable voltage drop limi...
Voorbeeld 1 van de 4 pagina's
In winkelwagenElectrical Phase 3 Module 1 Exam Questions and Complete Solutions 
 
The ampacity of a conductor is defined by the NEC to be the current in amperes, a conductor can carry continuously under the conditions of use without exceeding ______. 
a) its temperature rating 
b) the allowable voltage drop limi...
NEC Article 220 Branch Circuit, Feeder and Service Load Calculations Exam Questions and Complete Solutions
Voorbeeld 2 van de 5 pagina's
In winkelwagenNEC Article 220 Branch Circuit, Feeder and Service Load Calculations Exam Questions and Complete Solutions
Stuvia-klanten hebben meer dan 700.000 samenvattingen beoordeeld. Zo weet je zeker dat je de beste documenten koopt!
Je betaalt supersnel en eenmalig met iDeal, Bancontact of creditcard voor de samenvatting. Zonder lidmaatschap.
Samenvattingen worden geschreven voor en door anderen. Daarom zijn de samenvattingen altijd betrouwbaar en actueel. Zo kom je snel tot de kern!
Je krijgt een PDF, die direct beschikbaar is na je aankoop. Het gekochte document is altijd, overal en oneindig toegankelijk via je profiel.
Onze tevredenheidsgarantie zorgt ervoor dat je altijd een studiedocument vindt dat goed bij je past. Je vult een formulier in en onze klantenservice regelt de rest.
Stuvia is een marktplaats, je koop dit document dus niet van ons, maar van verkoper YourExamplug. Stuvia faciliteert de betaling aan de verkoper.
Nee, je koopt alleen deze samenvatting voor $20.49. Je zit daarna nergens aan vast.
4,6 sterren op Google & Trustpilot (+1000 reviews)
Afgelopen 30 dagen zijn er 81278 samenvattingen verkocht
Opgericht in 2010, al 14 jaar dé plek om samenvattingen te kopen