Pack
CAOHC Test/Exam Bundled Resources with Complete Solution | Expert Verified 2024/2025 | Guaranteed Success
CAOHC Test/Exam Bundled Resources with Complete Solution | Expert Verified 2024/2025 | Guaranteed Success
[Montrer plus]CAOHC Test/Exam Bundled Resources with Complete Solution | Expert Verified 2024/2025 | Guaranteed Success
[Montrer plus]0 dB HL does not mean what? - It does not mean that there is no sound at that level 
0-25dB HL represents what? - Normal hearing range 
90 dB HL represents what? - Typically the highest output level on a pure tone air conduction 
screening audiometer 
A laboratory value assigned to the individual po...
Aperçu 2 sur 5 pages
Ajouter au panier0 dB HL does not mean what? - It does not mean that there is no sound at that level 
0-25dB HL represents what? - Normal hearing range 
90 dB HL represents what? - Typically the highest output level on a pure tone air conduction 
screening audiometer 
A laboratory value assigned to the individual po...
1-2 - All audiometer tones should be presented for ____________ seconds 
14 - When there is a positive STS, the patient must be __________ hours noise free prior to retest 
140 dBP - Impulse noise becomes hazardous at 
140 dBP - Single hearing protection is required when the impulse noise exceeds 
2...
Aperçu 2 sur 8 pages
Ajouter au panier1-2 - All audiometer tones should be presented for ____________ seconds 
14 - When there is a positive STS, the patient must be __________ hours noise free prior to retest 
140 dBP - Impulse noise becomes hazardous at 
140 dBP - Single hearing protection is required when the impulse noise exceeds 
2...
"hearing levels" used by audiometers are also known as "sound pressure levels": - false 
29 CFR 1910.95 is an example of a standard, not a regulation: - false 
a sound level meter is used to calculate sound wave frequency: - false 
acoustic neuromas can manifest as an asymmetric or unilateral he...
Aperçu 3 sur 21 pages
Ajouter au panier"hearing levels" used by audiometers are also known as "sound pressure levels": - false 
29 CFR 1910.95 is an example of a standard, not a regulation: - false 
a sound level meter is used to calculate sound wave frequency: - false 
acoustic neuromas can manifest as an asymmetric or unilateral he...
A Earplugs fits properly if - It is full inserted into the ear canal 
According to OSHA Autometric testing records more must be kept for - Duration of employment 
Activities that the OHC is qualified to perform. - Audiometric testing 
otoscopic examination 
An exhaustive calibration check is require...
Aperçu 1 sur 3 pages
Ajouter au panierA Earplugs fits properly if - It is full inserted into the ear canal 
According to OSHA Autometric testing records more must be kept for - Duration of employment 
Activities that the OHC is qualified to perform. - Audiometric testing 
otoscopic examination 
An exhaustive calibration check is require...
A calibration performed by specialists with specialized equipment every 2 years, or when a repair is 
done is called a(n) ____________ calibration. 
a. acoustical 
b. exhaustive 
c. biological 
d. comprehensive - B 
. Advantages of a microprocessor audiometer are less examiner errors, requires littl...
Aperçu 4 sur 31 pages
Ajouter au panierA calibration performed by specialists with specialized equipment every 2 years, or when a repair is 
done is called a(n) ____________ calibration. 
a. acoustical 
b. exhaustive 
c. biological 
d. comprehensive - B 
. Advantages of a microprocessor audiometer are less examiner errors, requires littl...
'Hearing levels' used by audiometers are also known as 'sound pressure levels'. 
A. True 
B. False - B. False 
29 CFR 1910.95 is an example of a standard, not a regulation. 
A. True 
B. False - B. False 
Administrative controls to limit noise exposure include which of the following? 
A. Limiting...
Aperçu 2 sur 15 pages
Ajouter au panier'Hearing levels' used by audiometers are also known as 'sound pressure levels'. 
A. True 
B. False - B. False 
29 CFR 1910.95 is an example of a standard, not a regulation. 
A. True 
B. False - B. False 
Administrative controls to limit noise exposure include which of the following? 
A. Limiting...
________________ correlates well with risk of noise induced hearing loss - A-weighting 
________________ is used to filter and measured sound to capture sounds considered to be hazardous 
to hearing. - A-weighting 
_____________________ measurement during testing is best. - Continuous 
100 dB + 100 ...
Aperçu 3 sur 25 pages
Ajouter au panier________________ correlates well with risk of noise induced hearing loss - A-weighting 
________________ is used to filter and measured sound to capture sounds considered to be hazardous 
to hearing. - A-weighting 
_____________________ measurement during testing is best. - Continuous 
100 dB + 100 ...
_______ weighting is mostly used for measuring impulse sounds like that generated by weapons. - Z 
_______ weighting is unweighted across the human hearing frequency range of 20-20,000 Hz. - Z 
________ measurements are unweighted and therefore referred to as just dB. - Z 
#Days to notify individual...
Aperçu 3 sur 16 pages
Ajouter au panier_______ weighting is mostly used for measuring impulse sounds like that generated by weapons. - Z 
_______ weighting is unweighted across the human hearing frequency range of 20-20,000 Hz. - Z 
________ measurements are unweighted and therefore referred to as just dB. - Z 
#Days to notify individual...
Les clients de Stuvia ont évalués plus de 700 000 résumés. C'est comme ça que vous savez que vous achetez les meilleurs documents.
Vous pouvez payer rapidement avec iDeal, carte de crédit ou Stuvia-crédit pour les résumés. Il n'y a pas d'adhésion nécessaire.
Vos camarades écrivent eux-mêmes les notes d’étude, c’est pourquoi les documents sont toujours fiables et à jour. Cela garantit que vous arrivez rapidement au coeur du matériel.
Vous obtenez un PDF, disponible immédiatement après votre achat. Le document acheté est accessible à tout moment, n'importe où et indéfiniment via votre profil.
Notre garantie de satisfaction garantit que vous trouverez toujours un document d'étude qui vous convient. Vous remplissez un formulaire et notre équipe du service client s'occupe du reste.
Stuvia est une place de marché. Alors, vous n'achetez donc pas ce document chez nous, mais auprès du vendeur Tulloch. Stuvia facilite les paiements au vendeur.
Non, vous n'achetez ce résumé que pour $35.49. Vous n'êtes lié à rien après votre achat.
4.6 étoiles sur Google & Trustpilot (+1000 avis)
72042 résumés ont été vendus ces 30 derniers jours
Fondée en 2010, la référence pour acheter des résumés depuis déjà 14 ans