[Show more]As of what date did it become unlawful to release Class 1 and Class II 
refrigerants to the atmosphere? 
a. July 1, 1992 
b. July 1, 1993 
c. November 14, 1994 
d. January 1, 1996 
a. July 1, 1992 
 
 
 
What is the ozone layer and why is it important to us on Earth? 
a. Thin layer of R-22 in the at...
Preview 4 out of 82 pages
Add to cartAs of what date did it become unlawful to release Class 1 and Class II 
refrigerants to the atmosphere? 
a. July 1, 1992 
b. July 1, 1993 
c. November 14, 1994 
d. January 1, 1996 
a. July 1, 1992 
 
 
 
What is the ozone layer and why is it important to us on Earth? 
a. Thin layer of R-22 in the at...
When moisture exists in an operating system, what is most likely to occur? 
Acid will form. 
 
 
 
What factor(s) affects the speed of evacuation? 
1) The size of the equipment being evacuated. 
 
2)The ambient temperature. 
 
3) The amount of moisture in the system 
 
 
 
 
Must See! Eyewitness Cap...
Preview 1 out of 3 pages
Add to cartWhen moisture exists in an operating system, what is most likely to occur? 
Acid will form. 
 
 
 
What factor(s) affects the speed of evacuation? 
1) The size of the equipment being evacuated. 
 
2)The ambient temperature. 
 
3) The amount of moisture in the system 
 
 
 
 
Must See! Eyewitness Cap...
all of the above 
Refrigeration technicians who violate the clean air act can: 
A. lose their epa certification 
B. be fined. 
C. be required to appear in federal court 
D. all of the above 
 
 
 
november 1995 
It has been illegal to vent substitutes for CFC and HCFC refrigerants since: 
 
 
 
 
 
...
Preview 2 out of 12 pages
Add to cartall of the above 
Refrigeration technicians who violate the clean air act can: 
A. lose their epa certification 
B. be fined. 
C. be required to appear in federal court 
D. all of the above 
 
 
 
november 1995 
It has been illegal to vent substitutes for CFC and HCFC refrigerants since: 
 
 
 
 
 
...
what is CFCs? 
Chlorofluorocarbons (Chlorine, Fluorine, and carbon) 
 
 
 
What is HCFCs? 
Hydrochlorofluorocarbons (hydrogen, chlorine, fluorine, and carbon) 
 
 
 
 
Must See! Eyewitness Captures the Moment a Pair of Male Sea Lions Attack Beach-Goers 
 
POSTED 9 HOURS AGO 
0:00 / 0:00 
What is ASH...
Preview 2 out of 11 pages
Add to cartwhat is CFCs? 
Chlorofluorocarbons (Chlorine, Fluorine, and carbon) 
 
 
 
What is HCFCs? 
Hydrochlorofluorocarbons (hydrogen, chlorine, fluorine, and carbon) 
 
 
 
 
Must See! Eyewitness Captures the Moment a Pair of Male Sea Lions Attack Beach-Goers 
 
POSTED 9 HOURS AGO 
0:00 / 0:00 
What is ASH...
Refrigeration technicians who violate the Clean Air Act can: 
D) all of the above. 
 
 
 
After 1995, any supplies of CFC refrigerant to service existing units in the USA can only come from: 
A) recovery and recycling. 
 
 
 
 
 
Refrigerant that is recovered can be returned to: 
A) the same system ...
Preview 3 out of 16 pages
Add to cartRefrigeration technicians who violate the Clean Air Act can: 
D) all of the above. 
 
 
 
After 1995, any supplies of CFC refrigerant to service existing units in the USA can only come from: 
A) recovery and recycling. 
 
 
 
 
 
Refrigerant that is recovered can be returned to: 
A) the same system ...
To process refrigerant to a level that is equal to new product specifications as 
Reclaiming 
 
 
 
The low side test pressure data plate value should be used by a technician to determine a safe pressure for 
Leak testing 
 
 
 
 
 
Silicone elastomers are not compatible with what refrigerant 
HFC 
...
Preview 2 out of 7 pages
Add to cartTo process refrigerant to a level that is equal to new product specifications as 
Reclaiming 
 
 
 
The low side test pressure data plate value should be used by a technician to determine a safe pressure for 
Leak testing 
 
 
 
 
 
Silicone elastomers are not compatible with what refrigerant 
HFC 
...
As of what date did it become unlawful to release Class 1 and Class II refrigerants to the atmosphere? 
July 1, 1992. 
 
 
 
What is the ozone layer and why is it important to us on Earth? 
Protective shield for Earth from the sun's harmful ultraviolent (UV) rays in the stratosphere layer that exte...
Preview 1 out of 3 pages
Add to cartAs of what date did it become unlawful to release Class 1 and Class II refrigerants to the atmosphere? 
July 1, 1992. 
 
 
 
What is the ozone layer and why is it important to us on Earth? 
Protective shield for Earth from the sun's harmful ultraviolent (UV) rays in the stratosphere layer that exte...
Which type of refrigerant contains no chlorine? 
HFC's 
 
 
 
An ozone molecule contains; 
three oxygen atoms 
 
 
 
 
 
HFCs ________; 
will not damage stratospheric ozonem, but have a high GWP. 
 
 
 
Recover any remaining refrigerant and then render the cylinder useless, then recycle the metal i...
Preview 1 out of 3 pages
Add to cartWhich type of refrigerant contains no chlorine? 
HFC's 
 
 
 
An ozone molecule contains; 
three oxygen atoms 
 
 
 
 
 
HFCs ________; 
will not damage stratospheric ozonem, but have a high GWP. 
 
 
 
Recover any remaining refrigerant and then render the cylinder useless, then recycle the metal i...
What date was the sale of CFC's & HCFC's restricted to technicians certified in refrigerant recovery? 
November 14, 1994 
 
 
 
Section 608 of the Federal Clean Air Act requires technicians to what? 
Recover all refrigerants. 
 
 
 
 
 
The objective of the Clean Air Act is to protect what? 
The e...
Preview 2 out of 8 pages
Add to cartWhat date was the sale of CFC's & HCFC's restricted to technicians certified in refrigerant recovery? 
November 14, 1994 
 
 
 
Section 608 of the Federal Clean Air Act requires technicians to what? 
Recover all refrigerants. 
 
 
 
 
 
The objective of the Clean Air Act is to protect what? 
The e...
a vacum pump should be connected 
as far away from the pump as possible 
 
 
 
a high capacity vacuum pump and short, large diameter hoses will 
dramatically reduce emissions, pressure drop, and evacuation/dehydration time 
 
 
 
 
Must See! Eyewitness Captures the Moment a Pair of Male 
Sea Lions A...
Preview 2 out of 8 pages
Add to carta vacum pump should be connected 
as far away from the pump as possible 
 
 
 
a high capacity vacuum pump and short, large diameter hoses will 
dramatically reduce emissions, pressure drop, and evacuation/dehydration time 
 
 
 
 
Must See! Eyewitness Captures the Moment a Pair of Male 
Sea Lions A...
Are there drop-in replacements for R-12 systems? Why or why not? 
No because the new refrigerants are incompatible with the oils and lubricants used in R-12 systems. 
 
 
 
What type of oil is used in R-134a and what oils will it mix with? 
Ester based oils and they do not mix with other oils 
 
 
 ...
Preview 2 out of 13 pages
Add to cartAre there drop-in replacements for R-12 systems? Why or why not? 
No because the new refrigerants are incompatible with the oils and lubricants used in R-12 systems. 
 
 
 
What type of oil is used in R-134a and what oils will it mix with? 
Ester based oils and they do not mix with other oils 
 
 
 ...
As of what date did it become unlawful to release Class 1 and Class II 
refrigerants to the atmosphere? 
a. July 1, 1992 
b. July 1, 1993 
c. November 14, 1994 
d. January 1, 1996 
a. July 1, 1992 
 
 
 
What is the ozone layer and why is it important to us on Earth? 
a. Thin layer of R-22 in the at...
Preview 4 out of 81 pages
Add to cartAs of what date did it become unlawful to release Class 1 and Class II 
refrigerants to the atmosphere? 
a. July 1, 1992 
b. July 1, 1993 
c. November 14, 1994 
d. January 1, 1996 
a. July 1, 1992 
 
 
 
What is the ozone layer and why is it important to us on Earth? 
a. Thin layer of R-22 in the at...
Refrigeration technicians who violate the Clean Air Act can: - 
Lose their EPA certification, be fined, be required to appear in Federal court. 
 
 
 
After 1995, any supplies of CFC refrigerants to service existing units in the USA can only come from: - 
recovery and recycling. 
 
 
 
 
 
Refrigera...
Preview 3 out of 16 pages
Add to cartRefrigeration technicians who violate the Clean Air Act can: - 
Lose their EPA certification, be fined, be required to appear in Federal court. 
 
 
 
After 1995, any supplies of CFC refrigerants to service existing units in the USA can only come from: - 
recovery and recycling. 
 
 
 
 
 
Refrigera...
Recovery equipemnt used for the service or repair of small appliances must be certified by an EPA approved lab if the recovery equipment was made after 
November 15, 1993 
 
 
 
Recovery devices made before 11-15-93 and are used for recovery of refrigerant from small appliances must be capable of: 
...
Preview 2 out of 5 pages
Add to cartRecovery equipemnt used for the service or repair of small appliances must be certified by an EPA approved lab if the recovery equipment was made after 
November 15, 1993 
 
 
 
Recovery devices made before 11-15-93 and are used for recovery of refrigerant from small appliances must be capable of: 
...
Reusable refrigerant containers under high-pressure must be hydrostatically tested how often? 
5 years 
 
 
 
How much can a person be fined per day per violation for knowingly releasing a regulated substance that violates the Clean Air Act? 
$44,539 
 
 
 
 
 
HCFCs contain 
Hydrogen, Chlorine, Flu...
Preview 2 out of 11 pages
Add to cartReusable refrigerant containers under high-pressure must be hydrostatically tested how often? 
5 years 
 
 
 
How much can a person be fined per day per violation for knowingly releasing a regulated substance that violates the Clean Air Act? 
$44,539 
 
 
 
 
 
HCFCs contain 
Hydrogen, Chlorine, Flu...
When a new system has been assembled, the first thing to do is? 
Pressurize the system with an inert gas & leak check. 
 
 
 
After installation of a field-piped R-410A split heat pulp, the unit should first be? 
Pressurized with nitrogen then leak checked. 
 
 
 
 
 
The EPA regulations require tha...
Preview 2 out of 8 pages
Add to cartWhen a new system has been assembled, the first thing to do is? 
Pressurize the system with an inert gas & leak check. 
 
 
 
After installation of a field-piped R-410A split heat pulp, the unit should first be? 
Pressurized with nitrogen then leak checked. 
 
 
 
 
 
The EPA regulations require tha...
Technicians who perform sealed system service on small appliances must have; 
Type I or universal certification 
 
 
 
A small appliance is defined by EPA as; 
Appliances manufactured, charged, and hermetically sealed in a factory with 5 lbs or less of refrigerant 
 
 
 
 
 
Type I Certification is ...
Preview 1 out of 3 pages
Add to cartTechnicians who perform sealed system service on small appliances must have; 
Type I or universal certification 
 
 
 
A small appliance is defined by EPA as; 
Appliances manufactured, charged, and hermetically sealed in a factory with 5 lbs or less of refrigerant 
 
 
 
 
 
Type I Certification is ...
The sale of reclaimed CFC, HCFC, HFC, and HFO refrigerants is_______. 
Restricted to technicians who are EPA certified and refrigerant recovery 
 
 
 
A small Pliance is defined as a system that is 
Manufactured, fully charged, and hermetically sealed in a factory with a charge of 5 pounds or less 
...
Preview 2 out of 6 pages
Add to cartThe sale of reclaimed CFC, HCFC, HFC, and HFO refrigerants is_______. 
Restricted to technicians who are EPA certified and refrigerant recovery 
 
 
 
A small Pliance is defined as a system that is 
Manufactured, fully charged, and hermetically sealed in a factory with a charge of 5 pounds or less 
...
If a leaking appliance with a regulated refrigerant is not going to be repaired, it must be; 
A retrofitted or retired within 3 months. 
B retrofitted or retired within 12 months. 
C replaced within 3 months. 
D replaced within 12 months. 
B 
retrofitted or retired within 12 months. 
 
 
 
A high-pr...
Preview 2 out of 7 pages
Add to cartIf a leaking appliance with a regulated refrigerant is not going to be repaired, it must be; 
A retrofitted or retired within 3 months. 
B retrofitted or retired within 12 months. 
C replaced within 3 months. 
D replaced within 12 months. 
B 
retrofitted or retired within 12 months. 
 
 
 
A high-pr...
EPA 608 CORE CERTIFICATION EXAM WITH COMPLETE VERIFIED SOLUTIONS.
Preview 3 out of 17 pages
Add to cartEPA 608 CORE CERTIFICATION EXAM WITH COMPLETE VERIFIED SOLUTIONS.
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Stuvia is a marketplace, so you are not buying this document from us, but from seller GUARANTEEDSUCCESS. Stuvia facilitates payment to the seller.
No, you only buy these notes for $116.71. You're not tied to anything after your purchase.
4.6 stars on Google & Trustpilot (+1000 reviews)
67474 documents were sold in the last 30 days
Founded in 2010, the go-to place to buy study notes for 14 years now