the very first x ray image was taken by wilhem roe
cellulose acetate films replaced glass plates in
in
Schule, Studium & Fach
C4RT UPPER EXTREMITY
C4RT UPPER EXTREMITY
Verkäufer
Folgen
EvaTee
Deine Reviews
Inhaltsvorschau
C4RT UPPER
EXTREMITY PRACTICE
QUESTIONS WITH
100% CORRECT
ANSWERS!!
C4RT
Evatee 9/4/24 C4RT
,C4RT UPPER EXTREMITY PRACTICE
QUESTIONS WITH 100% CORRECT
ANSWERS!!
A German Physicist, Roentgen, is credited for discovering xrays in ________
Answer - 1895
The very first x-ray image was taken by Wilhem Roentgen of _______ just two
weeks after it's invention Answer - His wife Anna Bertha's hand
Cellulose acetate films replaced glass plates in Answer - 1918
In the year ____ x-ray cerebral angiography was developed at the University of
_____ Answer - 1927 - Lisbon
The first automatic film processor was introduced by PAKO corp in Answer -
1942
Digital Radiography (DR) first made an appearance around the year ____
Answer - 1970
George Luckey patented the utilization of phosphor imaging plates for storage
in 1975 creating modern Answer - Computed Radiography (CR)
CT was introduced in the Answer - 1970s
, A measure of the energy deposited into a medium by ionizing radiation per
unit mass Answer - Absorbed dose
The external exposure dose at 0.3 cm, equivalent to the lens of the eye at
tissue depth Answer - Lens Dose Equivalent
Mean grandular dose (MGD) (also known as average grandular dose) is
commonly used in Answer - Mammography
What is the Standard International (SI) unit of absorbed dose, which represents
the amount of radiation required to deposit 1 joule of energy into 1 kilogram of
any kind of matter Answer - gray (Gy)
______ is an approximate measure of the biological effects of radiation on
tissues and organs with a calculation modifier based on the type of radiation
Answer - Equivalent dose (HT)
The unit defined as the average radiation dose for a person being exposed to
normal, natural background radiation Answer - BERT (Background Equivalent
Radiation Time)
The sum of tissue equivalent doses received, combined with a tissue weighting
factor (wT), is used to calculated the ________________. The measurement is
used to show how the different dose combinations affect various types of
tissue Answer - effective dose
What organization launched a Dose Index Registry in May, 2011 to address the
lack of substantial database for determining the average dose indices for a CT
exam in the United States. Answer - American College of Radiology (ACR)
Alle Vorteile der Zusammenfassungen von Stuvia auf einen Blick:
Garantiert gute Qualität durch Reviews
Stuvia Verkäufer haben mehr als 700.000 Zusammenfassungen beurteilt. Deshalb weißt du dass du das beste Dokument kaufst.
Schnell und einfach kaufen
Man bezahlt schnell und einfach mit iDeal, Kreditkarte oder Stuvia-Kredit für die Zusammenfassungen. Man braucht keine Mitgliedschaft.
Konzentration auf den Kern der Sache
Deine Mitstudenten schreiben die Zusammenfassungen. Deshalb enthalten die Zusammenfassungen immer aktuelle, zuverlässige und up-to-date Informationen. Damit kommst du schnell zum Kern der Sache.
Häufig gestellte Fragen
Was bekomme ich, wenn ich dieses Dokument kaufe?
Du erhältst eine PDF-Datei, die sofort nach dem Kauf verfügbar ist. Das gekaufte Dokument ist jederzeit, überall und unbegrenzt über dein Profil zugänglich.
Zufriedenheitsgarantie: Wie funktioniert das?
Unsere Zufriedenheitsgarantie sorgt dafür, dass du immer eine Lernunterlage findest, die zu dir passt. Du füllst ein Formular aus und unser Kundendienstteam kümmert sich um den Rest.
Wem kaufe ich diese Zusammenfassung ab?
Stuvia ist ein Marktplatz, du kaufst dieses Dokument also nicht von uns, sondern vom Verkäufer EvaTee. Stuvia erleichtert die Zahlung an den Verkäufer.
Werde ich an ein Abonnement gebunden sein?
Nein, du kaufst diese Zusammenfassung nur für 18,41 €. Du bist nach deinem Kauf an nichts gebunden.