What is the minimum percentage needed to pass a written test for each specialty license? - Answer-70%
What is the first tier to the specialty license? - Answer-Gas Piping Installer
How many hours of educational training are required for the first specialty license? - Answer-60 Hours (Safemec ...
what is the minimum percentage needed to pass a wr
Schule, Studium & Fach
Gas Master
Gas Master
Verkäufer
Folgen
lectknancy
Deine Reviews
Inhaltsvorschau
Gas Fitters Exam Questions with
Verified Answers
What is the minimum percentage needed to pass a written test for each specialty
license? - Answer-70%
What is the first tier to the specialty license? - Answer-Gas Piping Installer
How many hours of educational training are required for the first specialty license? -
Answer-60 Hours (Safemec 305.02)
How many hours of on-job-training are required for the first specialty license? - Answer-
1000 Hours (Safemec 305.02)
What is the second tier to the specialty license? - Answer-Fuel Gas Installation
Technician
How many hours of educational training are required for the second specialty license? -
Answer-100 Hours Total (Safemec 305.03)
How many hours of on-job-training are required for the second specialty license? -
Answer-1000 On Job Training Hours (Safemec 305.03)
What is the third tier to the specialty license? - Answer-Fuel Gas Service Technician
How many hours of educational training are required for the third specialty license? -
Answer-140 Hours (Safemec 305.04)
How many hours of on-job-training are required for the third specialty license? - Answer-
2000 On Job Training Hour (Safemec 305.04)
How much does the initial fuel gas trainee license cost? - Answer-$90.00
How much does the initial fuel gas trainee renewal cost? - Answer-$80.00
How many years is a license active before expiration? - Answer-2 Years
When does a license expire? - Answer-2 years from date of issuance
How many questions at minimum are required on each specialty license test? - Answer-
100
What code covers the 1st and 2nd stage regulators on a LP system? - Answer-NFPA58
, A gas piping system was installed per code requirements in 2000, and now due to new
or revised code material it no longer meets code, we shall we do? - Answer-1.3 Unless
otherwise stated, the provisions of this code shall not be applied retroactively to existing
systems that were in compliance with the provisions of the code in effect at the time of
installation
Which table shall be referenced to design a gas piping system to have no more than
a, .5" W.C. pressure drop for the following conditions; LP gas, 11" W.C. available supply
pressure and black iron pipe? - Answer-6.3.1(D)
Which Table shall be referenced to design a gas piping system to have no more than
a .5" W.C. pressure drop for the following conditions; LP gas, 11" W.C. available supply
pressure and soft copper tubing? - Answer-6.3.1(F)
Which Table shall be referenced to design a gas piping system to have no more than
a .5" W.C. pressure drop for the following conditions; natural gas, 6" W.C. available
supply pressure and black iron pipe? - Answer-6.2.1(B)
What do first stage regulators compensate for? - Answer-Fluctuations in tank pressure
When adding appliances to an existing system what shall we do? - Answer-5.1.2
Ensure piping can handle additional load
What shall we do to black iron piping installed outdoors above ground? - Answer-7.2.2
Paint it
What do 2nd stage regulators compensate for? - Answer-Fluctuations in downstream
demand
What can cast iron be used for? - Answer-5.6.7.5(5(a)) Flanges
What Can't cast iron be used for? - Answer-5.6.2.1 Pipe
What is Industry best practice pressure drop we design piping systems for - Answer-0.5"
w.c
Do pressure regulators need to be readily accessible? - Answer-5.8.3 No
Do meters need to be readily accessible? - Answer-5.7.2.1 Yes
Do shutoffs need to be readily accessible? - Answer-7.8.2.1 Main gas shutoff valves
controlling several gas piping systems shall be readily accessible for operation and
installed so as to be protected from physical damage
Alle Vorteile der Zusammenfassungen von Stuvia auf einen Blick:
Garantiert gute Qualität durch Reviews
Stuvia Verkäufer haben mehr als 700.000 Zusammenfassungen beurteilt. Deshalb weißt du dass du das beste Dokument kaufst.
Schnell und einfach kaufen
Man bezahlt schnell und einfach mit iDeal, Kreditkarte oder Stuvia-Kredit für die Zusammenfassungen. Man braucht keine Mitgliedschaft.
Konzentration auf den Kern der Sache
Deine Mitstudenten schreiben die Zusammenfassungen. Deshalb enthalten die Zusammenfassungen immer aktuelle, zuverlässige und up-to-date Informationen. Damit kommst du schnell zum Kern der Sache.
Häufig gestellte Fragen
Was bekomme ich, wenn ich dieses Dokument kaufe?
Du erhältst eine PDF-Datei, die sofort nach dem Kauf verfügbar ist. Das gekaufte Dokument ist jederzeit, überall und unbegrenzt über dein Profil zugänglich.
Zufriedenheitsgarantie: Wie funktioniert das?
Unsere Zufriedenheitsgarantie sorgt dafür, dass du immer eine Lernunterlage findest, die zu dir passt. Du füllst ein Formular aus und unser Kundendienstteam kümmert sich um den Rest.
Wem kaufe ich diese Zusammenfassung ab?
Stuvia ist ein Marktplatz, du kaufst dieses Dokument also nicht von uns, sondern vom Verkäufer lectknancy. Stuvia erleichtert die Zahlung an den Verkäufer.
Werde ich an ein Abonnement gebunden sein?
Nein, du kaufst diese Zusammenfassung nur für 14,73 €. Du bist nach deinem Kauf an nichts gebunden.