Central Florida Fire Academy
Examens, Klausuren oder Prüfungen an der Central Florida Fire Academy. Suchst du Notizen von der/dem Central Florida Fire Academy? Wir haben viele Zusammenfassungen und Notizen deiner Schule oder Universität.
-
22
- 0
-
1
All courses for Central Florida Fire Academy
Aktuellste Notizen und Zusammenfassungen Central Florida Fire Academy
FL State Firefighter Test Questions and Answers 2023/2024
- Prüfung
- • 437 Seiten 's •
-
Central Florida Fire Academy•FL State Firefighter
Vorschau 4 aus 437 Seiten
FL State Firefighter Test Questions and Answers 2023/2024
water
- Notizen
- • 2 Seiten 's •
-
Central Florida Fire Academy•Nicet Level 1 Water Based Systems
Vorschau 1 aus 2 Seiten
water
NICET Level 2 Questions And Answers With Verified Updates 2023 
4 Consider a room which is 40' square. How many 15cd wall mounted strobes are required to adequately cover this space? 
 
Annually What is the testing frequency of a strobe? 
 
15 In a corridor application, visible appliances shall be rated not less than ________ cd? 
 
4 hours Consider a household fire alarm system where the primary power is provided by a circuit that can be switched off by means other than a circuit breaker. The ...
- Prüfung
- • 3 Seiten 's •
-
Central Florida Fire Academy•NICET Level 2
Vorschau 1 aus 3 Seiten
NICET Level 2 Questions And Answers With Verified Updates 2023 
4 Consider a room which is 40' square. How many 15cd wall mounted strobes are required to adequately cover this space? 
 
Annually What is the testing frequency of a strobe? 
 
15 In a corridor application, visible appliances shall be rated not less than ________ cd? 
 
4 hours Consider a household fire alarm system where the primary power is provided by a circuit that can be switched off by means other than a circuit breaker. The ...
Nicet Level 1 Water Based Systems Complete Questions And Answers 2023 
What is a purpose of a control valve Control Flow to water based fire protection system 
 
The gauge on the quick opening device shall indicate _____ as compared to the gauge on the system side of the dry pipe valve? the same pressure 
 
What type of test shall be provided when a valve is returned to service to determine that the valve is open? Valve status test 
 
What is a fire service main? A pipe and its appurtenances on ...
- Prüfung
- • 4 Seiten 's •
-
Central Florida Fire Academy•Nicet Level 1 Water Based Systems
Vorschau 1 aus 4 Seiten
Nicet Level 1 Water Based Systems Complete Questions And Answers 2023 
What is a purpose of a control valve Control Flow to water based fire protection system 
 
The gauge on the quick opening device shall indicate _____ as compared to the gauge on the system side of the dry pipe valve? the same pressure 
 
What type of test shall be provided when a valve is returned to service to determine that the valve is open? Valve status test 
 
What is a fire service main? A pipe and its appurtenances on ...
NICET Level 1 Study Guide Questions And Answers With Verified Solutions 
When testing a water level supervisory switch serving a pressure tank a signal shall indicate if the water level _____________from the required level 
 
(NFPA 72, Table 14.4.3.2 17 (j) (4) rises or falls over 3 inches 
 
If combination audible/visible appliances are installed the location of the installed appliance shall be determined by the requirements of _______. 
 
(Nfpa 72 18.4.8.1) the visible appliance 
 
What is the...
- Prüfung
- • 13 Seiten 's •
-
Central Florida Fire Academy•NICET Level 1
Vorschau 2 aus 13 Seiten
NICET Level 1 Study Guide Questions And Answers With Verified Solutions 
When testing a water level supervisory switch serving a pressure tank a signal shall indicate if the water level _____________from the required level 
 
(NFPA 72, Table 14.4.3.2 17 (j) (4) rises or falls over 3 inches 
 
If combination audible/visible appliances are installed the location of the installed appliance shall be determined by the requirements of _______. 
 
(Nfpa 72 18.4.8.1) the visible appliance 
 
What is the...
NICET Level 1 Questions And Answers | Complete Solutions 2023 
rises or falls over 3 inches (NFPA 72, Table 14.4.3.2 17 (j) (4) When testing a water level supervisory switch serving a pressure tank a signal shall indicate if the water level _____________from the required level 
 
the visible appliance (Nfpa 72 18.4.8.1) If combination audible/visible appliances are installed the location of the installed appliance shall be determined by the requirements of 
 
26 (Nec Annex C tables) What is the ...
- Prüfung
- • 2 Seiten 's •
-
Central Florida Fire Academy•NICET Level 1
Vorschau 1 aus 2 Seiten
NICET Level 1 Questions And Answers | Complete Solutions 2023 
rises or falls over 3 inches (NFPA 72, Table 14.4.3.2 17 (j) (4) When testing a water level supervisory switch serving a pressure tank a signal shall indicate if the water level _____________from the required level 
 
the visible appliance (Nfpa 72 18.4.8.1) If combination audible/visible appliances are installed the location of the installed appliance shall be determined by the requirements of 
 
26 (Nec Annex C tables) What is the ...
Firefighter 2 Final Exam Prep_Study 
Guide Questions And Answers (2022) 
(Verified Answers)
- Prüfung
- • 59 Seiten 's •
-
Central Florida Fire Academy•Firefighter 2
Vorschau 4 aus 59 Seiten
Firefighter 2 Final Exam Prep_Study 
Guide Questions And Answers (2022) 
(Verified Answers)
All Firefighter 1 Practice Test Questions 
And Answers 2023
- Prüfung
- • 54 Seiten 's •
-
Central Florida Fire Academy•Firefighter 1
Vorschau 4 aus 54 Seiten
All Firefighter 1 Practice Test Questions 
And Answers 2023
What is the mission of the fire service? - Answer To save lives and protect property 
 
What NFPA standard establishes basic training criteria for Firefighter I and Firefighter II - Answer 1001 
 
A ____ is a collection of rules enacted by law in a particular jurisdiction. - Answer Code 
 
Which of the following BEST describes the action first taken after an alert to the station? - Answer Dispatching of emergency services responders 
 
What task may a telecommunications center be assigned during...
- Prüfung
- • 9 Seiten 's •
-
Central Florida Fire Academy•Firefighter 1 & 2
Vorschau 2 aus 9 Seiten
What is the mission of the fire service? - Answer To save lives and protect property 
 
What NFPA standard establishes basic training criteria for Firefighter I and Firefighter II - Answer 1001 
 
A ____ is a collection of rules enacted by law in a particular jurisdiction. - Answer Code 
 
Which of the following BEST describes the action first taken after an alert to the station? - Answer Dispatching of emergency services responders 
 
What task may a telecommunications center be assigned during...
What is the mission of the fire service? 
 
A. To provide a variety of services 
 
B. To determine how fire loss occurs 
 
C. To save lives and protect property 
 
D. To regulate training of emergency responders - ANSWER ANS: C 
 
What NFPA ® standard establishes basic training criteria for Firefighter I and Firefighter II? 
 
A. 1001 
 
B. 1002 
 
C. 1021 
 
D. 1582 - ANSWER ANS: A 
 
A(an) ___ is a collection of rules enacted by law in a particular jurisdiction. 
 
A. code 
 
B. policy 
 
C. ...
- Prüfung
- • 28 Seiten 's •
-
Central Florida Fire Academy•FL Firefighter I, II
Vorschau 3 aus 28 Seiten
What is the mission of the fire service? 
 
A. To provide a variety of services 
 
B. To determine how fire loss occurs 
 
C. To save lives and protect property 
 
D. To regulate training of emergency responders - ANSWER ANS: C 
 
What NFPA ® standard establishes basic training criteria for Firefighter I and Firefighter II? 
 
A. 1001 
 
B. 1002 
 
C. 1021 
 
D. 1582 - ANSWER ANS: A 
 
A(an) ___ is a collection of rules enacted by law in a particular jurisdiction. 
 
A. code 
 
B. policy 
 
C. ...