There shall be a wall switch at each floor to control stairway lighting where the stairway has _____ or more risers 6 Bathtubs should be equipped with the waste outlets and overflow outlets connected to piping at least _____ inches in diameter 1.5 inches Doors between the garage and residence s...

[Show more]

Preview 4 out of 104  pages

  • October 24, 2022
  • 104
  • 2022/2023
  • Exam (elaborations)
  • Questions & answers
  • Unknown
avatar-seller
Home Inspector National Exam
Questions and Answers Rated A
There shall be a wall switch at each floor to control stairway lighting where the stairway has _____
or more risers ✔✔6


Bathtubs should be equipped with the waste outlets and overflow outlets connected to piping at
least _____ inches in diameter ✔✔1.5 inches


Doors between the garage and residence shall be equipped with a ✔✔Self-closing door


The _____ shall not be considered as an effective ground-fault current path ✔✔Earth


For natural ventilation for habitable rooms, the min openable area to the outdoors shall be _____
percent of the floor area being ventilated ✔✔4%


Fuel gas appliance connectors shall not exceed an overall length of _____ feet ✔✔6 ft.


What size are fuel-gas-fired domestic clothes dryer ducts ✔✔4 inches


The maximum amount of fuel oil stored above ground or inside a building shall be _____ gallons.
✔✔660 gals.


The minimum bet area of ventilation openings shall not be less than _____ square foot for each
_____ square feet of under-floor space ✔✔1 sqft. for each 150 sqft


Foundation anchor bolts shall be at least _____ inch in diameter and shall extend a minimum of
_____ inches into concrete or grouted cells of concrete masonry units ✔✔1/2 in. , 7 in.

,Outdoor and return air for a forced-air heating and cooling system shall not be taken from
✔✔Closets, bathrooms, toilet rooms, kitchens, garages, boiler rooms, furnace rooms,
unconditioned attics, or other dwelling units


Receptacles installed on 15 and 20 ampere rated branch circuits shall be on the _____ type
✔✔Grounding


Ceiling-suspended paddle fans shall be supported ________________ of the outlet box.
✔✔independently


Dwelling units shall be provided with heating facilities capable of maintaining a minimum room
temperature of ✔✔68 *f


Conductors in NM cable assemblies shall be rated at _________ Celsius. ✔✔90 *C


Address numbers shall be a minimum of _____ inches high with a minimum stroke width of _____
inch. ✔✔4 inches , 1/2 inch


Habitable space, hallways, corridors, bathrooms, toilet rooms, laundry rooms and portions of
basements containing these spaces shall have a ceiling height of not less than _______ feet. ✔✔7
feet


A Type B or a Type L gas vent shall terminate at least _____ feet in vertical height above the
highest connected APPLIANCE DRAFT HOOD or FLUE COLLAR. ✔✔5 feet


Open web truss or I-Joist floor assemblies require a ____-inch gypsum wallboard membrane,
____-inch wood structural panel membrane, or the equivalent on the underside. ✔✔1/2 And 5/8


Flanges and lips of load-bearing cold-formed steel floor framing members shall not be cut or ____.
✔✔Notched

,Gas vents over 12 inches in size shall terminate not less than _____ feet above the highest point
where they pass through the roof. ✔✔2 feet


Foundations for masonry chimneys shall be constructed of concrete or solid masonry at least _____
inches thick ✔✔12 inches


Supports and foundations for the outdoor unit of a heat pump shall be raised at least ___ inches
above the ground. ✔✔3 inches


Attic ventilation openings shall have a least dimension of _________ inch minimum to _________
inch maximum openings. ✔✔1/16 And 1/4


All wood beams, joists, studs and other combustible material shall have a clearance of not less
than _____ inches from the front faces and sides of masonry fireplaces. ✔✔2 inches


The minimum headroom in all parts of the stairway shall not be less than _____ feet, _____ inches
✔✔6 feet, 8 inches


A nosing not less than ____ inch but not more than ____ inches shall be provided on stairways
with solid risers. ✔✔3/4 And 1 1/4


Unattached decks not exceeding _____ square feet in area, that are not more than _____ inches
above grade do not require a permit. ✔✔200 sqft. And 30 inches


Gas appliance shut off valves shall be located in the same room as the appliance and not further
than _____ feet from the appliance ✔✔6 feet


BTU is abbreviation for _____ _____ ______, which is the quantity of heat required to raise the
temperature of 1 pound of water 1*F ✔✔British thermal unit

, Stairways shall not be less than ____ inches in clear width at all points above the permitted handrail
height and below the required headroom height. ✔✔36 inches


An automatic fire sprinkler system is not required when _____ or _____ are made to existing
townhouses that do not have a sprinkler system ✔✔Additions and or Alterations


Chimney shall extend at least _____ feet higher than any portion of a building within ____ feet.
✔✔2 feet, 10 feet


Window wells serving emergency escape and rescue openings shall be designed for proper ____.
✔✔Drainage


Braces wall panels shall be constructed with intermittent bracing method s, or the continuous
sheathing methods. Mixing of bracing methods shall be ______. ✔✔Permitted


Physical interconnection of smoke alarms is not required where ____ ___ alarms are installed.
✔✔Listed wireless
(All alarms must sound upon activation of one alarm).


Physical interconnection of smoke alarms is not required where ____ ___ alarms are installed.
✔✔Listed wireless
(All alarms must sound upon activation of one alarm).


A thermal barrier is not required for foam plastic insulation in an attic that is entered only for
purposes of _____ or ______. ✔✔Repairs or Maintenance


ANy portion of a masonry chimney located in the interior of a building or within an exterior wall
shall have a minimum air space clearance to combustibles of _____ inches. ✔✔2 inches

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller BestOfLuck. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $16.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

77764 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$16.49
  • (0)
  Add to cart