100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
NCLE Prep Exam 3 of 4 | with COMPLETE SOLUTION $10.49   Add to cart

Exam (elaborations)

NCLE Prep Exam 3 of 4 | with COMPLETE SOLUTION

 2 views  0 purchase
  • Course
  • Institution

The tolerance for the overall lens diamter according to the ANSI standards is: A. +/-0.005mm B. +/-0.05mm C. +/-0.01mm D. +/-0.1mm - B. According to the ANSI standards (Z80.2-1989), the tolerance for the overall diameter of a contat lens is +/-0.05mm. ANSI standards have been developed to maintain ...

[Show more]

Preview 2 out of 14  pages

  • November 2, 2022
  • 14
  • 2022/2023
  • Exam (elaborations)
  • Questions & answers
avatar-seller
NCLE Prep Exam 3 of 4 | with COMPLETE SOLUTION
The tolerance for the overall lens diamter according to the ANSI standards is:

A. +/-0.005mm
B. +/-0.05mm
C. +/-0.01mm
D. +/-0.1mm Correct Answer: B.

According to the ANSI standards (Z80.2-1989), the tolerance for the overall diameter of a contat
lens is +/-0.05mm. ANSI standards have been developed to maintain quality in the contact lens
industry. It is important to have an understanding of the ANSI guidelines.

All of the following will enable the practitioner to verify the overall rigid gas permeable lens
diameter except:

A. Slot gauge
B. Shadowgraph
C. Measuring magnifer
D. Radiuscope Correct Answer: D. Radiuscope

The slot gauge, shadowgraph and measuring magnifier will all enable the practitioner to verify
the overall lens diameter of rigid gas permeable lens. The radiuscope is an instrument that will
measure the base curve of a rigid lens.

Placing the concave side of a rigid gas permeable lens against the lens stop of the lensometer,
will provide you with which of the following?

A. Back vertex power
B. Front vertex power
C. Best vertex power
D. Closest vertex power Correct Answer: A. Back vertex power

By placing the back (posterior) surface of the rigid gas permeable lens against the lens stop, the
reading that results will be in back vertex power

An instrument that allows simultaneous verification of lens diameter, optic zone width and
peripheral curve width is:

A. Measuring magnifier
B. Ophthalmometer
C. Profile analyzer
D. Radiuscope Correct Answer: A. Measuring magnifier

An ophthalmometer, another name for the keratometer, cannot measure the listed parameters.
The profile analyzer evaluates the peripheral curve blends and the radiuscope measures the base

, curve of the rigid contact lens. The measuring magnifier is the only instrument that will measure
the parameters listed.

Assessment of the quality of the peripheral curves (blends) of a rigid contact lens is achievable
by the use of the:

A. Profile analyzer
B. Shadowgraph
C. Profile analyzer
D. Burton lamp Correct Answer: A. Profile analyzer

All of the listed instruments show that a rigid contact lens has blends. However, the only
instrument that can adequately assess the quality of the blends between the peripheral posterior
curve (PPC), intermediate posterior curve (IPC) and the central posterior curve (CPC), is the
profile analyzer.

The instrumental used for magnification of the edge of a rigid contact lens is a:

A. Keratometer
B. Shadowgraph
C. Profile analyzer
D. V-groove gauge Correct Answer: B. Shadowgraph

A keratometer measures the corneal curvature. A profile analyzer measures the peripheral curves
(blends) and a v-groove gauge measures the diameter of a rigid contact lens.

The tolerance for lens power under +/-10.00D is:

A. 0.12D
B. 0.25D
C. 0.37D
D. 0.50D Correct Answer: A. 0.12D

According to the ANSI standards (Z80.2 - 1989), the tolerance for the power of a contact lens
under +/-10.00D is +/-0.12D

Which of the following will NOT measure contact lens parameters?

A. Keratometer
B. Radiuscope
C. Burton lamp
D. Thickness gauge Correct Answer: A keratometer will measure the base curve of a lens with
an attachment known as a con-ta-check; however, a radiuscope is most frequently used. A
thickness gauge will measure the center thickness of a contact lens. A burton lamp evaluates the
fluorescein pattern similar to a slit lamp.

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller Classroom. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $10.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

77764 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling