PEACE model correct answer: Planning, Event, Assess, Communicate, Enviroment STARR Model correct answer: Spread out, Transfer, Avoid, Accept, Reduce How many nicked wires are allowed in a conductor with 19 strands of wire per conductor? correct answer: 2 Nicked, None Broken or Severed W...

[Show more]

Preview 3 out of 20  pages

  • April 27, 2023
  • 20
  • 2022/2023
  • Exam (elaborations)
  • Questions & answers
All documents for this subject (1)
avatar-seller
Classroom
AET2 SWE| 149 questions| with
complete solutions
PEACE model correct answer: Planning, Event, Assess, Communicate, Enviroment
STARR Model correct answer: Spread out, Transfer, Avoid, Accept, Reduce
How many nicked wires are allowed in a conductor with 19 strands of wire per conductor? correct answer: 2 Nicked, None Broken or Severed
What type of harness is preferred for maintenance considerations and why is it preferred? correct answer: Open harnesses are preferred for maintenance considerations. The wires or cables within the harness are uncovered which enables visual inspection and ease of repair when necessary.
What is the MINIMUM clearance when wiring must be routed parallel to flammable lines for short distance and a 6 inch clearance cannot be maintained? correct answer: the bundle and
flammable line shall be clamped with 2" minimum, so that there will be no relative motion between them.
When a two inch clearance cannot be maintained, the bundle shall be clamped....The minimum clearance shall be 1/2 inch. Route the wires on a level with, or above, the plumbing lines. Space clamps so that if a wire is broken at a clamp it will not contact the line. What is the MAXIMUM wiring bend radius for a wire group, bundle or harness? correct answer: 10 time the diameter of the largest wire.
What is step (a) of the general precautions for lacing or tying wire groups or bundles? correct answer: Lace or tie bundles tightly enough to prevent slipping, but not so tightly that the cord or tape cuts into or deforms the insulation. Be especially careful when lacing or tying coaxial cable, which has a soft dielectric insulation between the inner and outer conductors.
When is zip ties authorized to secure wire groups/bundles? correct answer: The use of plastic cable straps is strictly prohibited in all instances (refer to AS50881).
Which five heating tools are authorized to use on aircraft? correct answer: HT-900B, HT-920B, HT-71002, M and IR -
1759.
Which heating tools are authorized for the internal repair of fuel tanks and fuel cells? correct answer: The HT-900B, HT-920B, HT-71002, MC H-100-A and IR-1759 are the only authorized heat guns to be used when working on aircraft that have not been defueled and purged.
What is the MAXIMUM number of terminal lugs per post? correct answer: 4 terminal lugs per terminal post
Which wire size (AWG) should be used with a red terminal lug?
correct answer: Red 22-18 AWG What is the correct strip length for #22 AWG wire, when stripping length for small copper terminal lugs? correct answer: 6/32"
According to the NAVAIR 01-1A-505-1, Wire size with AWG of ___ and larger, shall be replaced in its entirety instead of being repaired? correct answer: WP14
What is used as an inspection aid during shield termination installation? correct answer: WP15
Which shield termination class is the only class authorized for military use? correct answer: WP15
List the characteristics of an unacceptable (overheated). correct answer: WP15
Which two letters identify terminal boards? correct answer: WP19
According to WP19 of the NAVAIR 01-1A-505-1, how should terminal lugs with various diameters be stacked? correct answer:
WP19
Summarize the meaning of the "WARNING" on Cadmium plate
material. correct answer: The use of cadmium has been restricted and/or banned for use in many countries due to environmental and health concerns.
List three different types of connector couplings. correct answer:
threaded, bayonet, breech, or push pull

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller Classroom. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $12.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

84669 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$12.99
  • (0)
  Add to cart