Dell EMC PowerEdge Corrective Maintenance 2023 Exam -Solved 100%
Using which of the following methods can RAID Management be accessed? Select two options that apply. - ANSWER-Dell OpenManage storage services <CTRL> + <R> for PERC BIOS Which of these functionalities can be performed by a PowerEdge RAID Controller? Select two options that apply. - ANSWER-Physically replace a failed drive, without powering off the server. Expand an existing array to include additional drives. Blower modules in servers help to ensure proper cooling of the server modules. Identify the location of the blower modules in the VRTX system shown below. Click the correct highlighted section, then Submit. - ANSWER-Right-hand side of the tower The image below shows an iDRAC Dashboard. Which of these sections can be used to access a remote server using the vKVM on your management station? Click the correct highlighted section, then Submit. - ANSWER-Virtual Console When installing two NVMe drives in a DSS8440 system, two slots are dedicated for NVMe drive installation. Which slots are they? Click the correct highlighted section, then Submit. - ANSWER-Slots 8 and 9 Which of the following is not an ability of the ePSA? - ANSWER-To run the Easy Restore after the system board replacement. What is the correct sequence of steps to run the ePSA through the Dell EMC Lifecycle Controller? - ANSWER-<F10> -> Hardware Diagnostics -> Run Hardware Diagnostics A collection of Server Event Logs (SEL) must be extracted and sent to the Technical Support team for troubleshooting using the Dell SupportAssist Collection utility. In the iDRAC GUI below, which tab contains the Dell SupportAssist feature? Click the correct highlighted section, then Submit. - ANSWER-Maintenance To add a Host Bus Adapter (HBA) to the system board, which server component could be used? - ANSWER-Peripheral Riser Card Which one of the following software is used to manage/monitor PowerEdge servers remotely? - ANSWER-iDRAC The PSU LED of a DSS 7000 flashes green five times then turns off. What could this indicate? - ANSWER-PSU mismatch. The image below shows the rear view of the Dell PowerEdge M1000e system. Identify the CMC in the system. Click the correct highlighted section, then Submit. - ANSWER-Top left While on a call to service a PowerEdge server, the reported issue is intermittent. The ability to stream real-time events and data logs is instrumental in diagnosing the problem. To successfully stream real-time metrics, the customer must have the correct iDRAC license installed. Which one of the iDRAC licenses enables this feature? - ANSWER-Datacenter The image shows the front view of the PowerEdge MX7000. Identify the compute sleds in the system. Click the correct highlighted section, then Submit. - ANSWER-Top-left drive bays, set of 12 bays A mini-PERC RAID Controller requires replacement. What are the steps taken to ensure the RAID controller is installed properly? - ANSWER-Angle the mini-PERC card so that one end of the card engages with the cardholder on the system board. Next, ensure the guide pins are aligned to the cable and the mini-PERC. Lastly, secure the two screws, being careful to not overtighten. The image below shows the rear view of the Dell PowerEdge MX7000 enclosure. Identify the Management Module(s) in the system. Click the correct highlighted section, then Submit. - ANSWER-Bottom-center When installing a TPM chip on a system board, which one of the following statements about the TPM are true? - ANSWER-By default, the TPM is always turned off in the BIOS.
Written for
- Institution
- Dell EMC PowerEdge
- Course
- Dell EMC PowerEdge
Document information
- Uploaded on
- August 28, 2023
- Number of pages
- 3
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
- dell emc poweredge
-
dell emc poweredge corrective maintenance