100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4,6 TrustPilot
logo-home
Examen

NCCER ELECTRICAL LEVEL 3 Module 6 'Distribution Equipment' 2023 Questions and Answers

Puntuación
-
Vendido
-
Páginas
4
Grado
A
Subido en
30-08-2023
Escrito en
2023/2024

NCCER ELECTRICAL LEVEL 3 Module 6 'Distribution Equipment' 2023 Questions and Answers Which of the following is true with regard to switchboards Switchboards are used to subdivide large blocks of power When installing wiring within switchgear, use self adhesive cable ties every ___. 12" (300mm) The maximum voltage that a piece of equipment can withstand is known as its ____. Basic impulse insulation level (BIL) Bolted pressure switches are often used in place of ___. Circuit breakers A transformer's temperature rise rating refers to ___. The maximum elevation above ambient temperature that the transformer can withstand without insulation damage A service has a three-phase supply with 14 single-pole circuits and 4 three-pole circuits. The minimum number of poles required is ___. 30 Per NEC Section 408.3(E)(1), AC phasing in switchboards must be labeled ___. A,B,C from front to back, top to bottom, or left to right when read facing the front of the switchboard On a typical electrical diagram, the standard abbreviation for a phase meter is __. PH The typical insulation resistance of equipment rated at 480V is ___. 100 megohms A typical overpotential test voltage for a used piece of equipment with a nominal voltage class of 600V is ___. 2,000 VDC A ground fault relay should be mounted in an enclosure ___. In a vertical position with the terminal block at the lower end In Industrial applications, medium voltage may refer to systems rated over ___. 1,000V up to 35,000V The term Interrupting rating refers to the ___. maximum current a device will safely interrupt at rated voltage Which of the following is NOT a general classification of circuit breakers? Fuse circuit breaker A 4,000A switchboard requires a minimum distance from the phase bus to the closest steel member of ____. 6" (150mm) When an unintended path is established between an ungrounded conductor and ground, it is called a(n)____. ground fault A transformer rated at more than 500kVA is considered a(n) ___. power transformer The term capacity on a transformer nameplate refers to ____. its ability to transfer energy

Mostrar más Leer menos
Institución
Grado








Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Grado

Información del documento

Subido en
30 de agosto de 2023
Número de páginas
4
Escrito en
2023/2024
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

NCCER ELECTRICAL LEVEL 3 Module 6 'Distribution
Equipment' 2023 Questions and Answers
Which of the following is true with regard to switchboards
Switchboards are used to subdivide large blocks of power
When installing wiring within switchgear, use self adhesive cable ties every ___.
12" (300mm)
The maximum voltage that a piece of equipment can withstand is known as its
____.
Basic impulse insulation level (BIL)
Bolted pressure switches are often used in place of ___.
Circuit breakers
A transformer's temperature rise rating refers to ___.
The maximum elevation above ambient temperature that the transformer can withstand
without insulation damage
A service has a three-phase supply with 14 single-pole circuits and 4 three-pole
circuits. The minimum number of poles required is ___.
30
Per NEC Section 408.3(E)(1), AC phasing in switchboards must be labeled ___.
A,B,C from front to back, top to bottom, or left to right when read facing the front of the
switchboard
On a typical electrical diagram, the standard abbreviation for a phase meter is __.
PH
The typical insulation resistance of equipment rated at 480V is ___.
100 megohms
A typical overpotential test voltage for a used piece of equipment with a nominal
voltage class of 600V is ___.
2,000 VDC
A ground fault relay should be mounted in an enclosure ___.
In a vertical position with the terminal block at the lower end
In Industrial applications, medium voltage may refer to systems rated over ___.
1,000V up to 35,000V
The term Interrupting rating refers to the ___.
maximum current a device will safely interrupt at rated voltage
Which of the following is NOT a general classification of circuit breakers?
Fuse circuit breaker
A 4,000A switchboard requires a minimum distance from the phase bus to the
closest steel member of ____.
6" (150mm)
When an unintended path is established between an ungrounded conductor and
ground, it is called a(n)____.
ground fault
A transformer rated at more than 500kVA is considered a(n) ___.
power transformer
The term capacity on a transformer nameplate refers to ____.
$10.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
LECTMAGGY Chamberlain College Of Nursing
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
145
Miembro desde
3 año
Número de seguidores
121
Documentos
6310
Última venta
3 meses hace
LECTMAGGY

Here, you will find everything you need in NURSING EXAMS AND TESTBANKS.Contact us, to fetch it for you in minutes if we do not have it in this shop.BUY WITHOUT DOUBT!!!!Always leave a review after purchasing any document so as to make sure our customers are 100% satisfied.

3.2

27 reseñas

5
7
4
3
3
11
2
0
1
6

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes