ICC Fire Inspector 1 Final Exam- Questions based on IFC When emergency power is provided to a Group I-2 occupancy, what is the MINIMUM amount of time that the emergency power shall be available? - ANSWER *1104.5.1 Emergency power duration and installation.* "... In Group I-2, the emergency po...

[Show more]

Preview 3 out of 19  pages

  • October 14, 2023
  • 19
  • 2023/2024
  • Exam (elaborations)
  • Questions & answers
avatar-seller
ICC Fire Inspector 1 Final Exam- Questions based on IFC
2023-2024


1. When emergency power is provided to a Group I-2 occupancy, what is the
MINIMUM amount of time that the emergency power shall be available? -
ANSWER *1104.5.1 Emergency power duration and installation.* "... In Group I-2,
the emergency power system shall provide power for not less than *90 minutes*
and consist of storage batteries...

2. In a building that is sprinklered and used for combustible material storage,
what MINIMUM distance below the sprinkler head deflectors shall the materials
be maintained? - ANSWER *315.3.1 Ceiling clearance.* "... a minimum of *18
inches* below sprinkler head deflectors in sprinklered areas of buildings."

3. What is the MINIMUM separation between an above ground 60,000 gallon
LP-Gas storage container and buildings, public ways, or lot lines of adjoining
property that could have a building constructed upon it? - ANSWER *Table
6104.3. 75'*

4. In a non-sprinklered building that has high-piled storage, what is the MINIMUM
width of the aisles? - ANSWER *3206.9.1.2 Nonsprinklered buildings* "Aisles in
nonsprinklered buildings shall be a minimum of *96 inches wide.*

5. What is the MINIMUM distance that a recreational fire can be conducted from a
structure? - ANSWER *307.4.2 Recreational fires.* "Recreational fires shall not be
conducted within *25 feet* of a structure or combustible material..."

6. What is the MAXIMUM size air supported temporary membrane structure that
can be erected without a permit? - ANSWER *105.7.16 Temporary membrane
structures and tents.* "A construction permit is required to erect an air-supported
temporary membrane structure or a tent having an area in excess of *400 square
feet.*

7. Fire sprinkler heads installed in an area where flammable vapor residue can
accumulate on heads shall be protected by means of a protective bag made of any
of the following materials: - ANSWER *2404.5.2 Protection of sprinklers.* "...Bags
used as a protective covering shall be 0.003-inch-thick *polyethylene or cellophane
or shall be thin paper*..."

8. Cryogenic piping shall be tested to be free of leaks with a pneumatic test. The

,piping shall be tested at - ANSWER *5505.1.2.6 Testing.* "...*110 percent* when
testing is conducted *pneumatically.*

9. When a mechanical ventilation alternative is used for smoke proofing a
vestibule, what is the MINIMUM fire protection rated allowed for the doors? -
ANSWER *IBC 909.20.4.1. 120 minute* rating

10. In the area where hot work is being done, what MAXIMUM distance from the
work shall a fire extinguisher be located? - ANSWER *3504.2.6 Fire extinguisher.*
"A minimum of one portable fire extinguisher complying with Section 906 and
with a minimum 2-Al20-B:C rating shall be readily accessible with *30 feet* of the
location where hot work is performed.

11. What is the MAXIMUM size cold deck used for a log storage area? - ANSWER
*2806.2 Cold decks.* Cold decks shall not exceed *500 feet in length, 300 feet in
width and 20 feet in height.* Cold decks shall be separated from adjacent cold
decks or other exposures by a minimum of 100 feet.

12. What is the MAXIMUM size of a tire warehouse before an automatic sprinkler
system throughout the building is required? - ANSWER *IBC 903.3.9.2.* 20,000
cubic feet.

13. Which of the following occupancies does not allow for the storage or use of
Class liquid and solid oxidizers? - ANSWER *6303.1.1.1.2 Group R occupancies.*
Class 4 liquid and solid oxidizers shall not be stored or used within *Group R
occupancies.*

14. How long after hot work has been completed on a job site can the FCO requires
to view the permit? - ANSWER *3503.3 Hot work program permit.* Hot work
permits, issued by an approved responsible person under a hot work program,
shall be available for review by the FCO at the time the work is conducted and for
*48 hours after work is complete.*

15. In storage rooms that contain cellulose nitrate (pyroxylin) plastic, what is the
MAXIMUM amount that can be stored without an approved automatic sprinkler
system? - ANSWER *6504.2 Fire protection.* The manufacture or storage of
articles of cellulose nitrate (pyroxylin) plastic in quantities exceeding *100
pounds* shall be located in a building or portion thereof equipped throughout
with n approved automatic sprinkler system in accordance with Section 903.3.1.1.

16. Buildings being constructed of four or more stories shall have the fire
protection standpipes installed so the construction is not more than - ANSWER

, *3313.1 Where required.* Such standpipes shall be installed when the progress of
construction is not more than *40 feet above the lowest level of fire department
access.*

17. In a room that contains an ozone gas generator, manual shutdown controls
shall be located at the generator and - ANSWER *6005.6 Manual shutdown*
Manual shutdown controls shall be... *within 10 feet of the main exit or exit access
door.*

18. If corrosive materials are stored closer to a public street or lot line than the
minimum required distance of separation, what type of fire barrier wall can be
used in lieu of such distance? - ANSWER *5404.2.2 Distance from storage to
exposures.* A *2-hour fire barrier* without openings or penetrations, and
extending not less than 3 inches above and to the sides of the storage area.



19. How thick of a reinforced roof slab would be required to achieve a 4 hour
fire-resistance rating using siliceous concrete? - ANSWER *IBC Table 722.2.2.1*
the minimum thickness of a 4-hour rating shall be *7"*

20. What MINIMUM volume room can be used for the production of ethylene gas
with a listed and labeled ethylene generator? - ANSWER *2506.2 Ethylene
generator rooms.* Ethylene generators shall be used in rooms having a volume of
not less than *1,000 cubic feet.*

21. An incinerator room is classified as an incidental use area. What is the required
separation and protection? - ANSWER *IBC Table 509* they shall have *2-hour
separation* and an *automatic sprinkler system. *

22. Outdoor storage of highly toxic and toxic compressed gases shall be kept at
what MINIMUM distance away from fresh air intakes? - ANSWER *6004.3.2.1.3 Air
intakes.* The storage or use area shall not be located *within 75 feet of air intakes.*

23. What Class of industrial oven or furnace operates at a temperature of ambient
to over 5,000°F? - ANSWER *202 Furnace Class D.* An oven or furnace that
operates at temperatures from above ambient to over 5,000°F and at pressures
normally below atmospheric using any type of heating system.

24. Storage tanks that contain hazardous materials shall be equipped with a device
to prevent overfilling of the tank if the tank's capacity exceeds - ANSWER
*5003.2.7 Liquid-level limit control.* Atmospheric tanks having a capacity greater
than *500 gallons* and which contain hazardous material liquids shall be

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller DrTOPNOTCH. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $14.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

80202 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling

Recently viewed by you


$14.99
  • (0)
  Add to cart