NYC MASTER ELECTRICIAN EXAM (Electrical exam) QUESTIONS WITH 100% COMPLETE ANSWERS. Type ____ is multiconductor cable identified for use as underground service entrance cable. Type USE cable Knife switch rated for more than 1200 Amps at 250Volts or less Can be used only as isolating switch, s...

[Show more]

Preview 2 out of 15  pages

  • November 15, 2023
  • 15
  • 2023/2024
  • Exam (elaborations)
  • Questions & answers
avatar-seller
NYC MASTER ELECTRICIAN EXAM (Electrical exam)
QUESTIONS WITH 100% COMPLETE ANSWERS.
Type ____ is multiconductor cable identified for use as underground service
entrance cable.
Type USE cable
Knife switch rated for more than 1200 Amps at 250Volts or less
Can be used only as isolating switch, shall not be opened under load
Track lighting with outlets in a bathroom is not allowed because ?
Track lighting has receptacle
Where internal combustion engines are used as the prime motor, an on site fuel
supply shall be provided with an on premise fuel supply sufficient for not less
than ____ hours full demand operation of the system
6 hours
Fixed in place X-ray equipment properly supplied by a branch circuit rated at not
over ____ amperes shall be permitted to be supplied through a suitable
attachment plug cap and hard service cable cord.
30 Amps
Where skin effect exist the ferromagnetic envelope shall be bonded at ____.
Both ends
GFCI protection at a carnival is not required for equipment at circuit if the
receptacle is of the ____type.
Locking
The maximum voltage drop from service point to the last over-current device in a
dwelling unit?
4%
Which of the following statements best describe the grounding requirement for
central vacuum outlet
Accessible non current carrying metal parts are required to be connected to an
equipment grounding conductor.
In healthcare facilities, patient bed receptacles located in general care areas shall
be supplied by at least two branch circuits, which ____permitted to originate from
two separate transfer switches on the emergency system
Are permitted
Patient care areas of healthcare facilities ____ areas such as business offices,
corridors, lounges ,day rooms, or similar areas
Do not include
The patient care area is any portion of the healthcare facility where patients are
intended to be ____or ____.
Examined or treated
Each general care area patient bed location in a healthcare facility must be
provided with four ____ or ____ duplex receptacles
Single or two

, A hospital is a building or portion thereof used for medical,
psychiatric,obstetrical , or surgical, care on a 24 hour basis of ____ or more
patients
Four
Where installed to reduce electrical noise for electronic equipment, electrical
continuity of the metal raceways shall not be required and metal raceway can
terminate a (an) ____ nonmetallic fitting or spacer on electronic equipment
Listed fitting
Feeder and branch circuit conductors within ____ inches of a Ballast shall have
an insulation temperature rating not lower than 90°C (194°F) unless supplying a
luminaiere marked as suitable for a different insulation temperature
3 inches
Manufactured wiring systems constructed with type MC cable shall be supported
and secured at intervals not exceeding ____ ft.
6 ft
Where a main bonding jumper or a system bonding jumper is a screw only the
screw shall be identified with a ____ that shall be visible with the screw installed
Green finish
Plug fuses a 15 amperes and lower rating shall be identified by a ____
configuration of the window, cap, or other prominent part to distinguish them
from fuses of higher ampere rating
Hexagon
The load for household electric clothes dryer's in a dwelling unit(s) shall be either
____ watts (volt-amperes) or the nameplate rating, which ever is larger, for each
dryer served ?
5000 watts
Service conductors installed as unjacketed multiconductor cable shall have a
minimum clearance of ____ windows that are designed to be opened, doors,
porches, stairs fire escape or similar locations.
3 ft (36 inches)
—— Cartridge fuses of the renewable type shall be permitted to be used only for
replacement in existing installation is where there is no evidence of over-fusing
or tampering.
Class H
Branch circuit conductors within ____inches of the ballast shall have an
insulation temperature rating not lower it 90°C 194°F
3" inches
The minimum radius of a field bend on trade size 1 "1/4 RMC is ____.
8
In a dwelling unit which appliance is allowed to have a 24"inch cord with
Attachment ground plug ?
Combination range hood/microwave oven
Type 3 Surge Protective devices can be installed on the load side of a branch
circuit overcurrent device up to the equipment served.if ____ the type 3 SPD
connection must be a minimum 30'ft of conductor a distance from the service or
separately derived system disconnect

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller ACADEMICAIDSTORE. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $13.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

72042 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$13.99
  • (0)
  Add to cart