Arthrex ACE Trainings exam 2023/2024 with 100% correct aswers
The MPFL is the main passive stabilizer against lateral patella displacement and is at its tightest in what degree of flexion? A. 0-30 degrees B. 0-180 degrees C. 60-90 degrees - correct answer A. 0-30 degrees What landmark does Schottles Point refer to when discussing MPFL? A. distal patella attachment B. superior patella attachment C. femoral attachment D. tibial attachment - correct answer C. femoral attachment Which statement regarding MPFL is TRUE: A. it inserts on the upper 1/2 (superior) of the patella B. it inserts on the lateral femur C. it inserts on the lower 1/2 (inferior) of the patella D. it prevents medial subluxation of the patella E. all of the above - correct answer A. it inserts on the upper 1/2 (superior) of the patella True or False: the use of the MPFL template included in the 3.9 mm BioComposite SwiveLock implant MPFL kit is advantageous in establishing the proper position of the femoral insertion of the MPFL, which is critical for maintaining proper joint biomechanics of the patellofemoral joint throughout range of motion. - correct answer True When using the MPFL template included in the 3.9 mm BioComposite SwiveLock implant MPFL kit the insertion point of the guide pin is approximately: A. 1 mm anterior to the posterior cortex extension line; 2.5 mm distal to the posterior articular border of the medial femoral condyle; proximal to the level of the posterior point of Blumensaat's line B. 2.5 mm anterior to the posterior cortex extension line; 1 mm distal to the posterior articular border of the medial femoral condyle; proximal to the level of the posterior point of Blumensaat's line C. 1 mm anterior to the posterior cortex extension line; 2.5 mm distal to the posterior articular border of the medial femoral condyle; distal to the level of the posterior point of Blumensaat's line - correct answer A. 1 mm anterior to the posterior cortex extension line; 2.5 mm distal to the posterior articular border of the medial femoral condyle; proximal to the level of the posterior point of Blumensaat's line The 3.9 BioComposite SwiveLock MPFL kits come in which of the two options: A. MPFL Implant System with BioComposite FastThread Interference Screw for femoral fixation and MPFL Implant System with TightRope implant for femoral fixation B. MPFL Implant System with InternalBrace implant for femoral fixation and MPFL Implant System with BioComposite FastThread Interference Screw for femoral fixation C. MPFL Implant System with PEEK Interference Screw for femoral fixation and MPFL Implant System with TightRope Implant for femoral fixation D. MPFL Implant System with InternalBrace implant for femoral fixation and MPFL Implant System with PEEK Interference Screw for femoral fixation - correct answer A. MPFL Implant System with BioComposite FastThread Interference Screw for femoral fixation and MPFL Implant System with TightRope implant for femoral fixation What is the appropriate diameter and length of the gracilis autograft tendon needed for MPFL reconstruction when using the 3.9mm BioComposite SwiveLock Implant MPFL Kit? A. Approximately 2 mm in diameter and minimum 18 cm in length B. Approximately 12 mm in diameter and minimum 25 cm in length C. Approximately 8 mm in diameter and minimum 16 cm in length D. Approximately 4 mm in diameter and minimum 18 cm in length E. All of the above are acceptable - correct answer D. Approximately 4 mm in diameter and minimum 18 cm in l
Written for
- Institution
- Arthrex
- Course
- Arthrex
Document information
- Uploaded on
- November 27, 2023
- Number of pages
- 12
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
-
arthrex ace trainings exam with 100 cor
Document also available in package deal