NATE Heat Pump Exam Questions And Answers
NATE Heat Pump Exam Questions And Answers Charging a heat pump with refrigerant is best accomplished in the _______ mode. A: Heating mode B: Cooling mode C: Defrost mode D: Emergency heating mode - ANS B: Cooling mode Heat pumps can provide both heating in the winter and cooling in the summer. In which mode is the heat pump more efficient? A: Heating mode B: Cooling mode C: Defrost mode D: Emergency heating mode - ANS A: Heating mode Which of the following components is exclusive to the heat pump? A: Condenser B: Oil separator C: Reversing valve D: Accumulator - ANS C: Reversing valve Which of the following airflow rates is the most reasonable for a heat pump system operating in the heating cycle? A: 200 cfm per ton B: 300 cfm per ton C: 400 cfm per ton D: 450 cfm per ton - ANS D: 450 cfm per ton During the heat pump's cooling cycle, the outdoor coil is utilized as a _________ while the indoor coil is utilized as a____________. A: Condenser, evaporator B: Evaporator, condenser C: Compressor, accumulator D: Accumulator, condenser - ANS A: Condenser, evaporator Heat is present in winter outdoor air until the outside air ambient temperature reaches a low temperature of: A: 0 degrees F B: 32 degrees F C: 273 degrees F D: -459 degrees F - ANS D: -459 degrees F Technically this is true, but not practical. A heat pump is doing good to continue to work below 10 deg F. The heat pump utilizes: A: Two filter-driers with check valves B: One bi-flow filter-drier C: A single mono-flow filter-drier in the liquid line D: Some use the bi-flow filter-drier and others use two filter-driers with check valves - ANS D: Some use the bi-flow- filter-drier and others use two filter-driers with check valves The correct way to size a heat pump is to perform both heating and cooling load calculations and select the heat pump size by: A: Adding the heating load and cooling loads B: Subtracting the smaller load from the larger load C: Using the heating load to size the system D: Using the cooling load to size the system - ANS D: Using the cooling load to size the system Auxiliary electric heat is necessary because: A: It provides heat for the home during defrosts B: It provides heat for the home in the event of a heat pump failure C: It provides heat for the home if the heat pump is unable to meet the demand for heat D: All of the above - ANS D: All of the above Reading a voltage across the contacts of the outdoor thermostat means: A: The thermostat contacts are closed B: The thermostat contacts are open C: The thermostat contacts are stuck D: The thermostat contacts are working correctly - ANS B: The thermostat contacts are open Which of the following is not a type of heat pump?
Written for
- Institution
- NATE
- Course
- NATE
Document information
- Uploaded on
- January 9, 2024
- Number of pages
- 15
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
Also available in package deal