U1 UST Installation/Retrofitting questions and answers 1. 1. One of the significant causes of leaks in underground liquid storage systems is : Improper Installation 2. 2. Written Plans are required to: obtain permits, solicit bids, and provide precise guidance for installers. 3. 3. The pla...

[Show more]

Preview 2 out of 15  pages

  • January 11, 2024
  • 15
  • 2023/2024
  • Exam (elaborations)
  • Questions & answers
avatar-seller
U1 UST Installation/Retrofitting questions and answers
1. 1. One of the significant causes of leaks in underground liquid storage
systems is : Improper Installation
2. 2. Written Plans are required to: obtain permits, solicit bids, and provide precise
guidance for installers.
3. 3. The plans should: Describe the property, identify the size and location of the
tanks, indicate the liquids to be stored and provide the location of the dispensers
and piping.
4. 4. Storage systems discussed in this recommended practice are usually
regulated by: Federal, state or local agencies.
5. 5. All owners should ensure that the equipment to be installed meets: applic-
able regulatory requirements before being installed
6. 6. Consult the local authorities who have jurisdiction in the area before
storage-system plans are: finalized or construction is initiated.
7. 7. All owners should ensure that the equipment to be installed meets all
applicable regulatory requirements before: Being installed.
8. 8. To avoid damage tanks must not be: dropped, dragged, or handled with
sharp objects.
9. 9. Tanks must not be dropped, dragged, or handled with sharp objects to
avoid: Damage to the tank
10. 10. The only time tanks really should be moved is when: for inspections and
testing.
11. 11. If a tanks is damaged at all throughout the moving process it must
be: Repaired in accordance with the manufacture's instructions.
12. 12. The proper way to move a tank is by lifting it, using the: Lift lugs that are
installed by the manufacturer.
13. 13. Tanks should be carefully lifted and lowered using: Cables or chains of
adequate length.
14. 14. When two lifting lugs are being used, the angle between the lifting cable
and vertical should be no more than: 30 degrees.
15. 15. Stockpile piping materials and equipment in a
on the job site: Secure area
16. 16. Confirm adherence to specifications by reporting to the owner about
any: detected damage that could result in leakage or premature corrosion.
17. 17. Pressure test single-walled tanks with to psig air pres-
sure, soaping all surfaces, seams and fittings while inspecting for bubbles.: 3
to 5
18. 18. Air testing with over psig (3 Psig for 12-Ft. Diameter FRP tanks) is
hazardous and may damage the tank: 5 psig



, U1 UST Installation/Retrofitting questions and answers
19. 19. Do not air test a tank that has previously contained: flammable or
combustible liquids
20. 20. Place barricades at the ends of tanks being tested.: Warning
21. 21. Avoid tank ends, man-ways, and fittings while the tank is under: Pres-
sure
22. 22. Release pressure in the tank before disconnecting any: gauges or test
fittings.
23. 23. Be aware some manufactures do not tighten fittings to allow for
during shipping and storage.: Temperature
changes
24. 24. True or False: Air tests are inconclusive without soaping and careful
inspection for bubbles?: True
25. 25. Tanks gauges must have a scale that will permit detection of
small changes in that might go undetected on gauges with a
.: Pressure, broader range.
26. 26. Since the best accuracy of gauges is at mid-range, and test pressures
must not exeed 5 psig, use a gauge with a maximum limit of or : 10
or 15 psig
27. 27. Check the gauges and before use: operation and
accuracy
28. 28. Underground storage systems may include vapor-recovery: Piping and
equipment
29. 29. What can cause premature storage-system failures : Debris
and other foreign materials
30. 30. Tank installers should have gone through training programs to improve
their skills and insure the install is : Successful
31. 31. kinds of plans are required to obtain permits, solicit bids,
and provide precise guidance for installers: written
32. 32. should insure that the equipment to be installed
meets all applicable regulatory requirements before beginning an installation-
: Owners
33. 33. Tanks should be inspected before installation: Visually
34. 34. 2 Gauges should be used to reduce : gauge
failure
35. 35. A pressure-relief device should e used to prevent
: Over pressurization
36. 36. True of False: Over pressurization could be a result of temperature
changes: True

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller NURSEFANUEL. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $13.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

81503 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$13.99
  • (0)
  Add to cart