EPA 608 Type 3 Questions and Answers Already Passed
EPA 608 Type 3 Questions and Answers Already Passed On low pressure chillers, moisture typically enters the refrigerant system through - Answer ️️ - air leaks from areas with gaskets or fittings The maximum test pressure for leak testing a low pressure centrifugal is: - Answer ️️ -10 psig Leak test and repair the chiller to reduce refrigerant loss from a pruge unit on CFC-11 chiller - Answer ️️ -... A hydrostatic tube test kit is used to: - Answer ️️ -determine if a tube leaks Commercial and industrial process refrigeration systems must be repaired when the leak rate exceeds ____ of the charge per year. - Answer ️️ -35% Refrigerant recovery typically start with liquid recovery it is faster. - Answer ️️ -... A rupture disc on a recovery vessel for a low pressure refrigerants relieves at: - Answer ️️ -15 psig According to ASHRAE Guideline 3-1996, if the pressure in a system rises from 1 mm Hg to a level above ____ during a standing vacuum test, the system should be checked for leaks. - Answer ️️ -2.5 mm Hg The primary water source for a recovery unit condensing coil is _____. - Answer ️️ -local municipal water supply When recharging a refrigeration system with R-11, what vaporpressure is necessary in the shells before changing with liquid? - Answer ️️ -16.9" Hg vacuum After recovering the liquid refrigerant you must: - Answer ️️ -recover the vapor refrigerant According to the EPA there is approximately _____ refrigerant vapor left in an average 350 ton R-11 chiller at 0 psig pressure once all the R-11 liquid has been removed. - Answer ️️ -100 pounds Charging refrigerant liquid into a refrigeration system when it is under a 29 inch Hg vacuum can cause the: - Answer ️️ -system water to freeze A system does not have to be evacuated all the way to the required level when: - Answer ️️ - leaks in the appliance make evacuation to the prescribed level unattainable Which of the foloowing repairs would ALWAYS be considered "major" under EPA's - Answer ️️ -replacement of evaporator coil Under EPA's regulation's _______ is used to pressurize a low pressure chiller for the purpose of opening the system for a non major repair? - Answer ️️ -warming the refrigerant If you are using a recovery machine manufactored AFTER 11-15-93 you must evacuate an low pressure appliance to _______ before making a major repair. - Answer ️️ -25 mm of Hg absolute After reaching the required recovery vacuum on a chiller, you should - Answer ️️ -Wait for at least a few minutes to see if the system pressure rises, indicating that there is till refrigerant in a liquid form or in the oil The pressure corresponding to 32 F for R-123 - Answer ️️ -20 inches of HG vacuum When evacuating a system the use of too large a vacuum pump can cause? - Answer ️️ - trapped water to freeze Refrigerant-11 at a pressure of 17 inches HG vacuum has a saturation temperature of: - Answer ️️ -35F During the evacuation of a system containing large amounts of moisture you can prevent freezing of this moisture by increasing the pressure with______gas - Answer ️️ -nitrogen ASHRAE standard 15-1994 requires that each machinery room must activate an alarm and mechanical ventilation beofre refrigerant concentrations exceed: - Answer ️️ -the threshold limit valve and time weighted aver
Written for
- Institution
- EPA certification
- Course
- EPA certification
Document information
- Uploaded on
- April 19, 2024
- Number of pages
- 10
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
-
epa 608 type 3 questions and answers already passe
Also available in package deal