Cardiac Instrumentation Test Review Questions with complete solution
Cardiac Instrumentation Test Review Questions with complete solution Cardiac Instrumentation Test Review Three types of PCI balloons are Over the wire (OTW), Monorail, and removable wire. True or False - correct answer False Balloon to artery selection with ratios of more than 1.2:1 are associated with increased complications. True or False - correct answer True Stents can be primarily placed without using a balloon prior to insertion. True or False - correct answer True An ostial lesion involving a bifurcation of two coronaries can sometimes be treated with two stents in each vessel. The stents are deployed simultaneously essentially touching at the proximal end of the stents. What are two names for this technique? - correct answer Doubled barrel stenting and kissing stents The guide catheter can cause a coronary dissection. True or False - correct answer True Post stenting the circumflex the physician injects contrast and you notice contrast is not washing out in the mid portion of the vessel. The obvious answer is a ... - correct answer Dissection The indications for PCI is/are: - correct answer -Bleeding Diathesis - Patient noncompliance with procedure -Patient noncompliance with post-PCI instructions and inability to take dual antiplatelet therapy