IDPX Exam Questions with 100% correct Answers Latest Update 2024/2025 (Verified)
IDPX Exam Questions with 100% correct Answers Latest Update 2024/2025 (Verified) When does the designer transfer all warranties and manuals? - correct answer when the designer is the seller of the goods when goods are shipped FOB destination, who has the title to them while in transit? - correct answer the seller when goods are shipped FOB factory, who has the title to them while in transit? - correct answer the buyer (transfer when goods leave the manufacturer/seller) what is involved in the parameter method of costing? - correct answer an expanded itemization of construction quantities and furnishings and assignment of unit costs to these quantities. With this type of budgeting, it's possible to evaluate the cost implication of each building component and to make decisions concerning quantity and quality that meet the original budget estimate what is matrix costing? - correct answer a technique in which a matrix is drawn with various alternatives and the individual elements that combine to make up the total cost of the alternatives. what term describes the furniture sales agreement between the client and interior designer? - correct answer a propsal The risk for furniture being damaged during shipment is assigned by the ______ - correct answer Uniform Commercial Code (UCC) The client is most typically involved with procurement of furniture through what? - correct answer a sales agreement IDPX Exam Questions with 100% correct Answers Latest Update 2024/2025 (Verified) When specifying a specialty flooring material, the interior designer can obtain unbiased information on the hazards of a cleaning agent, required for maintenance, from the ______ - correct answer MSDS Which of the following is not part of interior design delivery service? - correct answer installation who is responsible for inspection of furniture delivered and final inspection of furniture installed? What constitutes "acceptance of" or "taking charge or control over the furniture"? - correct answer the owner; upon final written acceptance While the interior designer is not responsible for structural design, they can design details to accommodate building movement caused by all of the following EXCEPT what? - correct answer building expansion - Expansion joints must be designed into the original building structure by the architect. TRUE/FALSE: Special seismic design is required for the below ceiling types? 1. structures in seismic design category a or b 2. ceilings with areas less than 144 sq ft 3. gypsum wallboard suspensions systems 4. plaster and lath ceilings - correct answer FALSE the measurement of business based on profit, planet, and people is known as what? - correct answer the triple bottom line Who would be responsible for scheduling the asbestos field test for the renovation of a building built in 1972? - correct answer contractor Utilizing BOMA standards, gross building area for a two-story building leased to a single tenant is measured: - correct answer To the outside face of the building and includes all interior area In designing the new office space for a client, the lease indicates there is 8,000 square feet of rentable space available to use to develop the office. This area _______ A. contains the corridors, restrooms and elevator lobbies B. contains the floor space within the exterior face of the building including the exterior wall C. is the floor area inhabitable by the tenant D. is the interior floor area excluding vertical penetrations through the floor - correct answer D buildings constructed prior to what year are likely to contain spray-on fireproofing and insulation containing asbestos? - correct answer 1973 Direct space adjacencies would be LEAST necessary in which business type? - correct answer Amazon customer service call center if a bidder requests a substitution during the bidding process, what must the interior designer do? A. forward request to owner for approval. If approved, issue change order stating this and sent to all bidders B. nothing, substitution requests are not considered until after the bid has been awarded C.review submission, approve or reject it, if approved issue addendum stating this and send to all bidders D. research proposed substitution to determine if it is acceptable, approve or reject substitution request, issue a change order stating this and send to all bidders - correct answer C What is the primary purpose of a retainage? - correct answer To protect the owner against defective and incomplete work who is responsible for submitting the Certificate of Occupancy (CO) to the owner? - correct answer contractor Who should be present at the final design development presentation for changing the office layout? A.project manager, office manager, design principal, facility manager B. general contractor, facility manager, design principal, client C. design principal, project manager, general contractor, client D. client, facility manager, office manager, project manager - correct answer C. design principal, project manager, general contractor, client Upon being notified that a project is ready for closeout, what should the interior designer do? - correct answer Conduct a punch list Which of the following would NOT be an example of a submittal? shop drawings samples construction drawings product brochures - correct answer construction drawings If a partially completed low partition constructed according to the interior designer's drawings falls over during construction and injures a worker, who is responsible? - correct answer contractor Per the General Conditions of the Contract for Construction, who is responsible for documentation? - correct answer interior designer Two weeks before the bids are due on a large restaurant project, one of the contractors asks if he can price a type of ceiling tile that was not listed in the specifications. What action should the interior designer take? - correct answer Tell the contractor to request approval in writing. What are the constraints for forward reach? - correct answer The high forward reach shall be 48 inches maximum where the reach depth is 20 inches maximum. Where the reach depth exceeds 20 inches , the high forward reach shall be 44 inches maximum and the reach depth shall be 25 inches maximum. Critical Radiant Flux refers to: - correct answer ASTM E-648/NFPA253 measures a horizontal floor covering's ability to resist supporting a flame, assigning a rating of Class I or II. Section 1203 of the 2018 IBC/International Building Codes deals with what important aspect of the Interior Environments? - correct answer It states that in all but Use Groups F, H S or U, interior spaces associated with human comfort must be provided with space heating. During the permitting process, who submits the drawings and specifications to the building department or AHJ? - correct answer licensed contractor NFPA 252 evaluates what? - correct answer the ability of a door assembly to resist the passage of flame, heat, and gases. TRUE/FALSE: a training room with a load of less than 50 in a business occupancy, is also classified as a business. - correct answer TRUE For office buildings, the overall building is allowed to use how many watts per square foot to power the interior lighting for the entire building? - correct answer .79 In the hallway of a commercial space, the bottom edge of a pendant light must be at least how high above the finished floor? - correct answer 80" ___________ are requirements that dictate how many accessible elements must be provided. For example, scoping provisions tell the designer how many seats in a restaurant must allow for wheelchair access or how many housing units in a complex must be accessible. - correct answer Scoping provisions TRUE/FALSE: Communication between the subcontractors and the owner should be through the contractor. - correct answer FALSE What is the BEST way for an interior designer to charge a building owner when the project requires space planning for tenants who lease building space and construction drawings that the building's contractors will use to build out each space? - correct answer area fee A __________ takes the total fee the designer will receive for the project and allocates it to the schedule and staff members who will work on the project, after deducting amounts for profit, overhead, and other expenses that will not be used for professional time. - correct answer fee projection TRUE/FALSE: In many cases the percentage of project cost may be beneficial because an economical or low-cost project may require just as much or more work as an expensive project. - correct answer FALSE What family of AIA Contract Documents accommodates projects that involve FF&E? - correct answer Interiors Family Which type of specifications used by most design firms, are pre written specifications that cover nearly all types of products, methods of installation, and other variables that relate to a specific product or construction activity? - correct answer guide specifications and Master specifications On a new design and construction project, what is CPM best used for? - correct answer identifying final delivery date of consultant drawings What interior design service is normally performed during the contract document phase of a project? A. coordinate the consultant contracts B. perform code review C. review shop drawings D. prepare furniture drawings - correct answer D. prepare furniture drawings The interior designer is about to contact and coordinate with utilities, governmental agencies and other regulatory bodies as required which phase of design are they currently working in? - correct answer programming and pre design When working on a renovation project, what would a designer's first consideration be when developing a rough floor plan if the client has expressed cost to be a major concern? electric circulation equipment plumbing - correct answer plumbing What is the easiest and least expensive type of construction to enclose a 1-hour rated corridor? - correct answer 5/8" (16 mm) Type X-gypsum wallboard on 3 5/8" (92 mm) metal studs A retail space has an existing condition of a 1′-0″ (305 mm) vertical step across the entire width of the space. In order to provide an accessible route to this area of the store without having to provide a ramp, what is the minimum clear space needed? - correct answer 36" x 240" with a slope of 1:20 The two primary methods of measuring space are based on the standards of what two organizations? IDEC & BOMA ANSI & BOMA IDEC & IFMA BOMA & IFMA - correct answer BOMA & IFMA One of the primary goals of the project design is to reduce energy consumption. Which of the following would NOT be a strategy to accomplish this goal? specify high reflective finishes complete the building commissioning process control ventilation avoid the use of CFC based refrigerants in tenant spaces - correct answer control ventilation Controlling ventilation is one of the 4 broad categories for maintaining good indoor air quality, but not conserving energy. The initial determination of area required for a client's program gives the net area rentable area usable area gross area - correct answer net area What is the efficiency factor of a single leased space? the amount of floor area needed by one person to function in the space the space required to accommodate the tenant's specific functions the ratio of the net area or net assignable area to the usable area the rentable area divided by the useable area - correct answer the ratio of the net area or net assignable area to the usable area A top architectural firm was running into a challenge with their interior designers. They would hire new inexperienced designers, but once trained, they would leave the firm and go to work for another local design firm who only hired experienced designers. What is the best way to combat this challenge and retain designers longer? seek legal counsel and pursue possible litigation against the competing company for their unprofessional and unethical recruiting practices contract with new employees using a formal contract that includes a restrictive covenant or noncompete clause when hiring her new designers inform them that they must work at the firm at least 2 years and when they leave they may not work at any firm in a 20 mile radius for a period of one year pay new employees more money - correct answer contract with new employees using a formal contract that includes a restrictive covenant or non-compete clause A transaction privilege tax license allows an interior design firm to ? exempt the firm from paying tax on items purchased for client conduct business from a specific state charge clients for shipping and storage of furniture buy and sell furniture - correct answer buy and sell furniture The A152-2019 serves what purpose? Construction Change Directive Change Order Vendor Payment Application Purchase Order - correct answer Purchase Order As outlined in the General Conditions of the Contract for Construction, who pays for any field tests/inspections beyond what is required in the contract documents? General Contractor Both the Interior Designer and General Contractor Both the Owner and the General Contractor Interior Designer - correct answer Both the Owner and the General Contractor What is the PRIMARY purpose of meeting minutes, transmittal forms, and memos? Communicate information to stakeholders during a project. Use as supporting documentation for design elements recorded on project drawings. Use as supplementary information as part of a building permit application. Record all events and decisions in order to reduce potential liability. - correct answer Communicate information to stakeholders during a project. Upon being notified that a project is ready for closeout, what should the interior designer do? Insure the owner receives as-built drawings Submit a final certificate for payment Conduct a punch list Issue a Certificate of Substantial Completion - correct answer Conduct a punch list
Written for
- Institution
- IDPX
- Course
- IDPX
Document information
- Uploaded on
- May 23, 2024
- Number of pages
- 36
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
- idpx
- latest update 2024
- graded
- verified answers
-
idpx exam questions with correct answers