BREAST ARDMS Exam Questions And Answers (Verified And Updated)
9 views 0 purchase
Course
ARDMS Breast Registry
Institution
ARDMS Breast Registry
BREAST ARDMS Exam Questions And
Answers (Verified And Updated)
Which artifact may cause structures to look deeper than they actually are? -
answerPropagation speed error
The optimum operating frequency for a broad-bandwidth transducer would be : - answer10
MHz
In breast sonography, what is NO...
BREAST ARDMS Exam Questions And Answers (Verified And Updated) Which artifact may cause structures to look deeper than they actually are? - answer✔✔Propagation speed error The optimum operating frequency for a broad -bandwidth transducer would be : - answer✔✔10 MHz In breast sonography, what is NOT significantly affect ed by the limited field of view when imaging superficial structures? - answer✔✔Temporal resolution Which of the following affects the actual intensity of the sound utilized for imaging? - answer✔✔Output power The dynamic range of a display is the : - answe r✔✔Number of gray shades Using color/power doppler while a patient hums to better dilineate a mass is called : - answer✔✔Fremitus A standoff pad thicker than 1 cm is not recommended because it will : - answer✔✔Affect the optimal placement of the fixed elev ation plane focus Which type of transducer does NOT allow the sonographer to vary the focusing capabilities? - answer✔✔Mechanical sector When taking patient history for a breast sonogram, what information from a previous mammogram would not be considered r elevant? - answer✔✔Name of radiographer Image of amplitude is affected by : - answer✔✔Power, overall gain, and time gain compensation (TGC) High -frequency transducers used in breast imaging provide excellent resolution of breast tissues but limited : - answer✔✔Penetration When using the 123 -ABC method of annotation, "B" would indicate : - answer✔✔Mass is in the mammary zone In the 123 -ABC method of annotation, the number denote the : - answer✔✔Distance from the nipple Which method of patient positioning is the best for evaluation the medial aspect of the breast ? - answer✔✔Supine The two -handed technique is used to image : - answer✔✔The main breast duct and nipple Which of the following transducers would be the best choice for breast imaging ? - answer✔✔10 MHz linear array Selecting multiple focal zones will : - answer✔✔Decrease frame rate When viewing a mammogram, one always sees the marker in the region toward : - answer✔✔Axilla If a breast sonographic image is labeled "Rt. AR 2:00 1A", the area described i s : - answer✔✔Antiradial scan of the right breast, upper inner quadrant near the nipple, under the skin When viewing a mammogram, a mass is marked near the CC marker in the right breast. This will indicate to the sonographer that the mass is located : - answer✔✔In the lateral breast A transducer that can operate at multiple frequencies is said to have : - answer✔✔Broad bandwidth All of the following statements about high -frequency transducers are true : - answer✔✔- Axial resolution is increased - Lateral re solution is increased - Sound penetration is decreased - Best for breast imaging The following statement about high -frequency transducers is false : - answer✔✔Sound travels faster Decreasing depth will : - answer✔✔Increase the frame rate Increasing the ove rall gain control will : - answer✔✔Cause artifactual echoes What allows for better demonstration of small, tortuous vessels ? - answer✔✔Power doppler What affects the frame rate ? - answer✔✔Number of focal zones and size of image Ideally, the elevational focus for breast imaging should be fixed at : - answer✔✔1.5 cm An increase in the intensity of echoes beneath a structure is called : - answer✔✔Enhancement What is not a good indication for performing a breast sonogram? - answer✔✔Evaluate a mass for microcalcifications When setting the TGC control for breast imaging, the following tissue should demonstrate a medium level of gray. - answer✔✔Fat The lactiferous ducts are best seen when scanning : - answer✔✔Radial The orthogonal (defin ed as perpendicular) view from the longitudinal scan is : - answer✔✔Transverse Adequate penetration of the breast is determined by imaging the : - answer✔✔Pectoral muscles If a mass is isoechoic with surrounding tissues, what maneuver would accentuate the mass to make it show up better ? - answer✔✔Apply harmonics What transducer feature would not be good for breast imaging ? - answer✔✔Curved linear array format Lateral resolution is best at the : - answer✔✔Focal zone Which technique would eliminate useful a rtifacts such as posterior enhancement and shadowing? - answer✔✔Spatial compound imaging According to AIUM standards, all of the following information should be indicated on sonographic images : - answer✔✔- Patient's name / ID # - Patient's age - Facility name - Date What information should not be indicated of sonographic images ? - answer✔✔Patient's social security number What is considered an appropriate annotation method for breast imaging ? - answer✔✔- Side / Quadrant - Clock face - 123-ABC What stateme nt would be false when considering doppler artifacts ? - answer✔✔If the gain and filter settings are too low, it can cause noise What statements are true when considering doppler artifacts ? - answer✔✔- If the filter setting is too high, it will inhibit th e ability to detect low -velocity blood flow. - A PRF / velocity scale that is too low will cause aliasing. - If the doppler angle is perpendicular to flow, no flow will be detected. - Spectral mirroring causes a duplication of the waveform on the opposite side of the baseline What is true about propagation speed error ? - answer✔✔- If the propagation speed is slower than 1540 m/sec, posterior echoes will be displayed on he sonogram deeper than they actually are. - If the propagation speed is faster than 1540 m/sec, reflectors will appear closer to the transducer than they actually are. The brightness of echoes on an ultrasound image is affected by : - answer✔✔- Overall gain - Power output - Dynamic range - TGC The brightness of echoes on an ultrasound image is not affected by : - answer✔✔Transducer frequency What would not be part of the examination preparation? - answer✔✔Present the informed consent to the patient for signature What would be part of the examina tion preparation? - answer✔✔- Obtain pertinent clinical information from the patient. - Explain the examination to the patient. - Review the pertinent correlative imaging tests. - Know the indication for the exam. The supine oblique postition : - answer✔✔- Evenly distributes the breast tissue - Allows better evaluation of the outer breast. - Places the nipple in the center. - Minimizes breast thickness for better penetration Echo palpation is used to : - answer✔✔- Localize a mass. - Determine if a mass is c ompressible or not. For general breast scanning, which patient position is considered the best? - answer✔✔- Supine oblique. - Contralateral posterior oblique.
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller sirjoel. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for $14.49. You're not tied to anything after your purchase.