Firefighter 2 final Exam Questions With 100% Correct Answers
Firefighter 2 final Exam Questions With 100% Correct Answers What does an initial radio report provide? (116-117) A. Transfer of command B. Description of conditions as they appear C. Procedure for requesting a special alarm D. Operations from a legal and statistical standpoint - answerb Which of the following should be in an arrival report? (117) A. Number of victims B. Discussion of command C. Correct address of the incident D. Emergency medical services on scene - answerc Which of the following provides the telecommunications center with a continuous record of actions at scene? (117-118) A. Arrival report B. Progress report C. Initial radio report D. Personal accountability report - answerc What task may a telecommunications center be assigned during a progress report? (118) A. Requesting multiple or special alarms B. Providing periodic time transmissions C. Warning personnel of impending hazard on scene D. Giving command in the absence of command staff - answerb ___ must follow a broadcast process that begins with a clear statement that alerts all listeners. (119) A. Arrival reports B. Emergency radio traffic C. Tactical progress reports D. Additional resource requests - answerb Which of the following would be a reason to request a personnel accountability report (PAR)? (121) A. The primary search is started. B. A secondary search is completed. C. An emergency evacuation is ordered. D. The public information officer requests it. - answerc Which of the following BEST explains why information is gathered for a postincident report? (122) A. Reviewing tactical operations errors B. Determining trends in firefighter injuries C. Suggesting locations that need preincident surveys D. Providing information to media before the official report - answerb What does the National Fire Incident Reporting System (NFIRS) do? (122) A. Informs other responding units of current conditions B. Gives description of conditions as they appear on scene C. Outlines necessary information needed to complete incident reports D. Provides telecommunications center with continuous record of actions at scene - answerc What general information is in a postincident report? (122-123) A. Witness names B. Dispatch transmissions C. Estimated cost of damage D. Number of people interviewed - answerc Knowing types of doors and door hardware can help firefighters: (190) A. judge roof safety. B. predict fire development. C. select correct forcible entry tools. D. select the right type of vertical tactical ventilation. - answerc Which of the following BEST describes a primary dangerous building condition? (191) A. Conditions that suppress fire B. Conditions that allow tactical ventilation C. Conditions that contribute to fire spread D. Conditions that permit occupants to safely escape - answerc Fuel loading is defined as the maximum heat produced if: (191) A. no combustible materials are present. B. all combustible materials in a given area burn. C. nothing but combustible materials are present. D. none of the combustible materials in a given area burn. - answerb What is the most effective defense against heavy content fuel loading? (191-192) A. Proper inspection and code enforcement B. Restricting the types of combustible materials used C. Adopting local standards that limit multistory buildings D. Not allowing the use of combustible materials in construction - answera Vertical tactical ventilation can be defined as channeling smoke from the: (192) A. lowest point in a building. B. highest point in a building. C. point in a building that has the most windows. D. point in a building that has the least windows. - answerb The critical temperature for steel trusses is: (193) A. 300°F (149°C). B. 500°F (260°C). C. 900°F (482°C). D. 1,000°F (538°C) - answerd Which type of roof is used whenever large open floor spaces with limited interior support is needed? (193) A. Lantern B. Mansard C. Sawtooth D. Bowstring truss - answerd Which of the following BEST describes a possible construction hazard? (194) A. Fire detection systems may be damaged. B. Furnishings may contribute to fire spread. C. Building is subject to rapid fire spread because protective features are not in place. D. Danger increases because occupants and belongings remain in one part of the building while work goes on in the other. - answerc Renovation, age of the structure, weather, and loads are all: (195) A. renovations hazards. B. structural collapse factors. C. building construction hazards. D. impossible to estimate the impact of on a structure. - answerb Which of the following BEST describes when structural collapse may occur? (197) A. It can occur when all the factors are met. B. It can only occur before fire suppression. C. It can only occur during fire suppression. D. It can occur well after the fire is extinguished. - answerd In what fire stage is structural collapse very likely? (197) A. Incipient B. Growth C. Fully developed D. Decay - answerd
Written for
- Institution
- Firefighter 2
- Course
- Firefighter 2
Document information
- Uploaded on
- June 5, 2024
- Number of pages
- 60
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
-
firefighter 2 final exam questions with 100 corre