- ✅✅ -True or false two waves with identical frequencies must interfere
constructively

-10dB - ✅✅ -An ultrasound system is set at 0dB and is transmitting at full
intensity. What is the output power when the system is transmitting at 10% of full
intensity?

-3 dB - ✅✅ -an ultrasound system is set At 0dB and is transmitting at full
intensity. What is the output power when the system is transmitting at 50% of full
intensity?

-milli - ✅✅-10-3
(True or false) gray scale can be changed by the sonographer. - ✅✅-True or
false) gray scale can be changed by the sonographer.


✅✅
(True/false) Doppler shifts are always created when the source and receiver are
in motion relative to each other. - -False

0.0% - ✅✅-What is the maximum value of the duty factor ?
0.06cm - ✅✅-Which of the following is the best lateral resolution?

0.1 - ✅✅-According to the aium statement on bio effects, there statements on
bio effects, there have been no confirmed bio effects below intensities of_______
watts per square centimeter SPTA.

0.3MHz - ✅✅-3000,000 cycles occurs in a second, what is the waves
frequency?

0.5cm -✅✅-If the spatial pulse length is 10mm,what is the axial resolution ?
0.5dB/cm - ✅✅-What is the approximate attenuation coefficient of 1 MHz US in
soft tissue ?

,0.6dB/cm/MHz - ✅✅-Attenuation of US is soft tissue is closest to ?
1-10MHz - ✅✅-What are typical clinical Doppler frequencies?
1,500 m/s - ✅✅-The speed of US in soft tissues is closest to ?

1.0 - ✅✅-The duty factor for continuous wave ultrasound is ?

1.54 m/s - ✅✅-The propagation speed of US in the AIUM test objects is ?

1% - ✅✅-The most likely amount of reflection at a boundary between soft
tissue is ?

10 -✅✅-How many bits are needed to represents 1024 gray shades ?
10 cm - ✅✅-A pulse is emitted by a transducer and is traveling in soft tissue.
The go return time, or time of flight,of a sound pulse is 130 microseconds. What
is the reflector depth ?

✅✅--micro
10^-6 -

100 mW/cm2 - ✅✅-Biological effects have not been documented below what
intensity (SPTA)?

14 kHz - ✅✅ -A Doppler exam is performed with a 5kHz probe and PRF of 15
kHz.which of these Doppler shifts will create aliasing ?

✅✅-The frequency closest to the lower limit of US is?
15,000 Hz -

1kHz - ✅✅-What is the frequency of a wave with 1 msec period?

2-10MHz - ✅✅-What is the range of frequencies created by medical
diagnostics Doppler transducer ?

2kHz - ✅✅-What is the most typical Doppler shift measured clinically?

, 2times - ✅✅ -The distance to a target is doubled. The time-of-flight for a pulse
to travel to the target and back is ?

✅✅-Which of the following Is not preprocessing?
3-D rendering -

30 KHz - ✅✅-Which of following sound waves is ultrasonic and least useful in
diagnostic imaging?

3cm - ✅✅ -An object is located at a depth of 10 cm. The imaging depth is 7cm.
At what depth will a reflection from the object appear on the image ?

4-✅✅-How many bits are needed to represents 16 shades of grey?
45mm - ✅✅-Depth calibration of a machine measures 100mm spaced wires to
be 90mm apart.scanning reflectors 50mm apart. Scanning reflectors 50mm
apart,what will the machine calculate the distance to be ?

5MHz - ✅✅ -The fundamental frequency of a transducer is 2.5MHz. What is the
second harmonic frequency?

6- ✅✅-How many cm are 60 millimeters?
6 - ✅✅-How many data bits are needed to represent 46 gray shades?

60-75 degrees - ✅✅-What Doppler angle is most inaccurate?

6dB - ✅✅-Sound intensity is decreased your 75%. How many decibels of
attenuation is this?

8dB - ✅✅ -An US wave travels through two media and has attenuation of 3dB
in the first and 5dB in the second. What is the total attenuation ?

90 degrees - ✅✅-For Doppler,which incident angle results in no shifts ?
99% - ✅✅-The most typical amount of transmission at a boundary in biologic
media is ?

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller Hkane. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $7.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

70840 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$7.99
  • (0)
  Add to cart