RMO Practical Exam With 100% Verified Guaranteed Answers.
C. what component is the primary educator - correct answer steam jetv #1 outlet C.FTC that is automatically valve between the condensor & evaporator - correct answer Hot Gas Bypass Valve C.FTC which measures liduid refrigerant temperature leaving the intercooler - correct answer liquid temperature transducer in the alley way C.What device signals high water in the hot well or FTC to warn of high levels in the hot well - correct answer High sensor on the side of the hot well C.Frind the primary steam condensor - correct answer surface condensor C.Locate the component to Service the rupture disk - correct answer access valve on pressure relief valve C.Find the compressor variable guide vanes - correct answer Located in the alley you will find the compressor vanes and the inlet actuator it will high lightcas a whole C.FTC that releases Vaccum on the turbine shut down - correct answer Vacuum breaker on top of the turbine C.What removes heat from the chilled brine that circulates - correct answer The Evaporator C.FTC that is used to add oil to the compressor - correct answer oil sevice valve on the sump C.FTC that automatically fills the cooling towers 1 or 2 - correct answer Water make up valves C.FTC that cools the compressor oil - correct answer Oil cooler back of compressor C.FTC used during extreme low load conditions - correct answer Hot gas bypass C.Find the main compressor for condensing stream - correct answer surface condenser C.FTC that regulates the flow to the intercooler - correct answer Flash Gas Valve C.FTC that cools the first stage of the compressor - correct answer flash gas vavle/line C.FTC which gives you evaporator pressure - correct answer low pressure transducer C.Find the oil cooler for the compressor - correct answer on the back of the compressor C.Where is the high pressure cut out - correct answer on discharge line C.FTC that control the flow between intercooler and compressor - correct answer Flash Gas Return Valve C.Where is the overboard valve - correct answer below the recirculating valve on the surfacr condensor C.Find the device thats shuts down the system when the discharge pressure is too high - correct answer High pressure cut out C.FTC that absorbs heat from the chill water brine through the building - correct answer Evaporator C.FTC which performs 1st stage cooling of steam exhaust of the turbine - correct answer the surface condenser C.FTC which cools steam turbine oil - correct answer the turbine oil cool next to the steam bypass and below the turbine oil filter C.FTC which maintains evaporator pressure during low loads - correct answer Hot gas bypass C.FTC PUMP marked 1 which removes water resulting from condensation steam - correct answer condensate pump #1 C.Find the high pressure that connects to the recovery unit - correct answer Vapor recovery valve C.FTC that regulates chiller capacity - correct answer inlet vanes C.Find the high side valve piped to the recovery unit - correct answer Vapor recovery unit C.What component on the high side of rhe chillers is connected to the recovery unit - correct answer Vapor recovery unit C.Which component would be considered on the high side of the system - correct answer Vapor recovery valve C.What is the oil temperature of the compressor - correct answer oil tem guage C.FTC that tells the control panel what the compressors discharge is - correct answer Dis charge temp C. Find the temperture of warter leaving the refrigerant condensore - correct answer look at the condensor water outlet thermometer FTC that signals the recirculating valve when the hot well is too low - correct answer silver box next to hot well which component vents steam from the consensor in the event of high steam pressure - correct answer Atmospheric valve Find the component marked 1 to remove consenser steam - correct answer condensate pump What component is used to throttle the condenser - correct answer Plug Valve Find the power line feeding oil heater #1 or #2 - correct answer Oil Heater Cable Cover Find The Discharge stop valve for system 1 or 2 Or Suction Service stop valve - correct answer Discharge/Suction service valves Find where you can check the refrigerant charge for system 1 or 2 - correct answer Sight glass FTC that reduces capacity for compressor #2 during low loads - correct answer Unloader Identify the compressor on system #1 or #2 to recover from the filter drier - correct answer Filter access valve Which component will stop liquid refrigerant when not powered - correct answer Solenoid Find the high side stop valve of system #2 - correct answer Discharge service valve What pressure the compressor before start up - correct answer Solenoid valve Where is the electric heater cable to heat the oil in system #1 - correct answer oil heater cable Find the water shut off valve on the chiller suction side of the condensor - correct answer Chilled water inlet
Written for
- Institution
- FDNY Z51
- Course
- FDNY Z51
Document information
- Uploaded on
- July 11, 2024
- Number of pages
- 6
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers