A boat's hull potential is measured: - ANS-Between a reference cell and the engine negative
terminal or its bus.

A boat's hull potential is measured: - ANS-Between a reference cell and the engine negative
terminal or its bus.

A-28 -APPENDIX 2 -ELECTRICAL TEST PROCEDURES FOR GALVANIC CURRENT
BLOCKING The galvanic isolator shall be connected in series with a variable DC power supply
as shown below. The supply shall be capable of adjusting the voltage output in fine increments
in establishing the exact barrier voltage or intrinsic junction voltage. Once the device is biased
into conduction, measurements shall be taken of the resultant current. The ammeter shall have
a resolution of at least+/- _milliampere. The voltmeter shall have a resolution of at least +/-1
millivolt. The connection diagram is shown below (see A-28.12.3.1 through A-28.12.3.3). -
ANS-1

A-28 -APPENDIX 2 -ELECTRICAL TEST PROCEDURES FOR GALVANIC CURRENT
BLOCKING The galvanic isolator shall be connected in series with a variable DC power supply
as shown below. The supply shall be capable of adjusting the voltage output in fine increments
in establishing the exact barrier voltage or intrinsic junction voltage. Once the device is biased
into conduction, measurements shall be taken of the resultant current. The ammeter shall have
a resolution of at least+/- _milliampere. The voltmeter shall have a resolution of at least +/-1
millivolt. The connection diagram is shown below (see A-28.12.3.1 through A-28.12.3.3). -
ANS-1

A-28 -APPENDIX 4 - LOADTEST ()))%) vs. TEMPERATURE Thermocouples shall be placed in
critical locations on the isolator body and its internal components. The isolator shall be mounted
as intended on a 1/2-inch piece of plywood. The unit shall be placed in series with an AC power
supply, ammeter, and load resistor.as shown. The power supply shall be adjusted to allow ___%
of rated current to be conducted through the isolator. The current shall be maintained until
temperatures stabilize. The galvanic isolator shall be designed so that no exterior surface
exceeds 90°C (194°F). (See sections A-28.12.7.1 through A-28.12.7.4.) All data shall be
recorded using a digital temperature and computerized data logger. The ammeter shall have a
resolution of at least +/- 1 mA. For galvanic isolators that are not intended for installation in
machinery areas or ignition protected areas, the thermocoupled sample shall be preconditioned
- ANS-135

A-28 -APPENDIX 4 - LOADTEST ()))%) vs. TEMPERATURE Thermocouples shall be placed in
critical locations on the isolator body and its internal components. The isolator shall be mounted
as intended on a 1/2-inch piece of plywood. The unit shall be placed in series with an AC power
supply, ammeter, and load resistor.as shown. The power supply shall be adjusted to allow ___%

,of rated current to be conducted through the isolator. The current shall be maintained until
temperatures stabilize. The galvanic isolator shall be designed so that no exterior surface
exceeds 90°C (194°F). (See sections A-28.12.7.1 through A-28.12.7.4.) All data shall be
recorded using a digital temperature and computerized data logger. The ammeter shall have a
resolution of at least +/- 1 mA. For galvanic isolators that are not intended for installation in
machinery areas or ignition protected areas, the thermocoupled sample shall be preconditioned
- ANS-135

A-28 -APPENDIX 4 - LOADTEST (135%) vs. TEMPERATURE Thermocouples shall be placed
in critical locations on the isolator body and its internal components. The isolator shall be
mounted as intended on a _-inch piece of plywood. The unit shall be placed in series with an AC
power supply, ammeter, and load resistor.as shown. The power supply shall be adjusted to allow
135% of rated current to be conducted through the isolator. The current shall be maintained until
temperatures stabilize. The galvanic isolator shall be designed so that no exterior surface
exceeds 90°C (194°F). (See sections A-28.12.7.1 through A-28.12.7.4.) All data shall be
recorded using a digital temperature and computerized data logger. The ammeter shall have a
resolution of at least +/- 1 mA. For galvanic isolators that are not intended for installation in
machinery areas or ignition protected areas, the thermocoupled sample shall be preconditioned
fo - ANS-44198

A-28 -APPENDIX 4 - LOADTEST (135%) vs. TEMPERATURE Thermocouples shall be placed
in critical locations on the isolator body and its internal components. The isolator shall be
mounted as intended on a _-inch piece of plywood. The unit shall be placed in series with an AC
power supply, ammeter, and load resistor.as shown. The power supply shall be adjusted to allow
135% of rated current to be conducted through the isolator. The current shall be maintained until
temperatures stabilize. The galvanic isolator shall be designed so that no exterior surface
exceeds 90°C (194°F). (See sections A-28.12.7.1 through A-28.12.7.4.) All data shall be
recorded using a digital temperature and computerized data logger. The ammeter shall have a
resolution of at least +/- 1 mA. For galvanic isolators that are not intended for installation in
machinery areas or ignition protected areas, the thermocoupled sample shall be preconditioned
fo - ANS-44198

A-28 -APPENDIX 4 - LOADTEST (135%) vs. TEMPERATURE Thermocouples shall be placed
in critical locations on the isolator body and its internal components. The isolator shall be
mounted as intended on a 1/2-inch piece of plywood. The unit shall be placed in series with an
AC power supply, ammeter, and load resistor.as shown. The power supply shall be adjusted to
allow 135% of rated current to be conducted through the isolator. The current shall be
maintained until temperatures stabilize. The galvanic isolator shall be designed so that no
exterior surface exceeds _____. (See sections A-28.12.7.1 through A-28.12.7.4.) All data shall
be recorded using a digital temperature and computerized data logger. The ammeter shall have
a resolution of at least +/- 1 mA. For galvanic isolators that are not intended for installation in
machinery areas or ignition protected areas, the thermocoupled sample shall be preconditioned
for 2 h - ANS-90°C (194°F)

,A-28 -APPENDIX 4 - LOADTEST (135%) vs. TEMPERATURE Thermocouples shall be placed
in critical locations on the isolator body and its internal components. The isolator shall be
mounted as intended on a 1/2-inch piece of plywood. The unit shall be placed in series with an
AC power supply, ammeter, and load resistor.as shown. The power supply shall be adjusted to
allow 135% of rated current to be conducted through the isolator. The current shall be
maintained until temperatures stabilize. The galvanic isolator shall be designed so that no
exterior surface exceeds _____. (See sections A-28.12.7.1 through A-28.12.7.4.) All data shall
be recorded using a digital temperature and computerized data logger. The ammeter shall have
a resolution of at least +/- 1 mA. For galvanic isolators that are not intended for installation in
machinery areas or ignition protected areas, the thermocoupled sample shall be preconditioned
for 2 h - ANS-90°C (194°F)

A-28 -APPENDIX 4 - LOADTEST (135%) vs. TEMPERATURE Thermocouples shall be placed
in critical locations on the isolator body and its internal components. The isolator shall be
mounted as intended on a 1/2-inch piece of plywood. The unit shall be placed in series with an
AC power supply, ammeter, and load resistor.as shown. The power supply shall be adjusted to
allow 135% of rated current to be conducted through the isolator. The current shall be
maintained until temperatures stabilize. The galvanic isolator shall be designed so that no
exterior surface exceeds 90°C (194°F). (See sections A-28.12.7.1 through A-28.12.7.4.) All data
shall be recorded using a digital temperature and computerized data logger. The ammeter shall
have a resolution of at least +/- 1 mA. For galvanic isolators that are not intended for installation
in machinery areas or ignition protected areas, the thermocoupled sample shall be
preconditioned - ANS-2

A-28 -APPENDIX 4 - LOADTEST (135%) vs. TEMPERATURE Thermocouples shall be placed
in critical locations on the isolator body and its internal components. The isolator shall be
mounted as intended on a 1/2-inch piece of plywood. The unit shall be placed in series with an
AC power supply, ammeter, and load resistor.as shown. The power supply shall be adjusted to
allow 135% of rated current to be conducted through the isolator. The current shall be
maintained until temperatures stabilize. The galvanic isolator shall be designed so that no
exterior surface exceeds 90°C (194°F). (See sections A-28.12.7.1 through A-28.12.7.4.) All data
shall be recorded using a digital temperature and computerized data logger. The ammeter shall
have a resolution of at least +/- 1 mA. For galvanic isolators that are not intended for installation
in machinery areas or ignition protected areas, the thermocoupled sample shall be
preconditioned - ANS-2

A-28 -APPENDIX 4 - LOADTEST (135%) vs. TEMPERATURE Thermocouples shall be placed
in critical locations on the isolator body and its internal components. The isolator shall be
mounted as intended on a 1/2-inch piece of plywood. The unit shall be placed in series with an
AC power supply, ammeter, and load resistor.as shown. The power supply shall be adjusted to
allow 135% of rated current to be conducted through the isolator. The current shall be
maintained until temperatures stabilize. The galvanic isolator shall be designed so that no
exterior surface exceeds 90°C (194°F). (See sections A-28.12.7.1 through A-28.12.7.4.) All data
shall be recorded using a digital temperature and computerized data logger. The ammeter shall

, have a resolution of at least +/-_ mA. For galvanic isolators that are not intended for installation
in machinery areas or ignition protected areas, the thermocoupled sample shall be
preconditioned f - ANS-1

A-28 -APPENDIX 4 - LOADTEST (135%) vs. TEMPERATURE Thermocouples shall be placed
in critical locations on the isolator body and its internal components. The isolator shall be
mounted as intended on a 1/2-inch piece of plywood. The unit shall be placed in series with an
AC power supply, ammeter, and load resistor.as shown. The power supply shall be adjusted to
allow 135% of rated current to be conducted through the isolator. The current shall be
maintained until temperatures stabilize. The galvanic isolator shall be designed so that no
exterior surface exceeds 90°C (194°F). (See sections A-28.12.7.1 through A-28.12.7.4.) All data
shall be recorded using a digital temperature and computerized data logger. The ammeter shall
have a resolution of at least +/-_ mA. For galvanic isolators that are not intended for installation
in machinery areas or ignition protected areas, the thermocoupled sample shall be
preconditioned f - ANS-1

A-28 -APPENDIX 5 - SHORT CIRCUITTEST The galvanic isolator shall be tested for its ability
to withstand the application of power from a short circuit test source capable of delivering
_________ symmetrically through the isolator as specified in AP S TABLE I, TABLE I 0-1. (See
sections A-28.12.8.1 through A-28.12.8.l.). Three applications of short circuit current shall be
applied to the galvanic isolator being tested. The duration of each short circuit test shall be at
least one full cycle. Each short circuit test shall be applied immediately after the test equipment
has been reset to the operational mode from the previous test. The electrical and mechanical
characteristics of the isolator shall be unchanged. - ANS-AC current (RMS)

A-28 -APPENDIX 5 - SHORT CIRCUITTEST The galvanic isolator shall be tested for its ability
to withstand the application of power from a short circuit test source capable of delivering
_________ symmetrically through the isolator as specified in AP S TABLE I, TABLE I 0-1. (See
sections A-28.12.8.1 through A-28.12.8.l.). Three applications of short circuit current shall be
applied to the galvanic isolator being tested. The duration of each short circuit test shall be at
least one full cycle. Each short circuit test shall be applied immediately after the test equipment
has been reset to the operational mode from the previous test. The electrical and mechanical
characteristics of the isolator shall be unchanged. - ANS-AC current (RMS)

A-28-APPENDIX 1-AC CONDUCTIVITY TEST The galvanic isolator shall be tested at ___% of
rated voltage and current, for 5 minutes, in series, connected to a resistive load. The galvanic
isolator shall not introduce a voltage drop greater than 2.5 volts at ___% of the galvanic isolator
ampacity rating. The ammeter shall have a resolution of at least +/- 1mA. (See A-28.12.2.1, and
A-28.12.2.2). - ANS-100

A-28-APPENDIX 1-AC CONDUCTIVITY TEST The galvanic isolator shall be tested at ___% of
rated voltage and current, for 5 minutes, in series, connected to a resistive load. The galvanic
isolator shall not introduce a voltage drop greater than 2.5 volts at ___% of the galvanic isolator

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller lydiaomutho. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $7.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

82185 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$7.99
  • (0)
  Add to cart