100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
Maine Gas Exam - with codes Questions and Answers New (2024/2025) Solved 100% Correct $7.99   Add to cart

Exam (elaborations)

Maine Gas Exam - with codes Questions and Answers New (2024/2025) Solved 100% Correct

 8 views  0 purchase
  • Course
  • Maine Gas
  • Institution
  • Maine Gas

A 10" natural gas main pipe is installed to supply a power plant; however, the pipe has a bad valve that must be replaced. How much of the 10" must be purged with inert gas before work can begin? - All of it NFPA 54 Table 8.3.1 A 127 foot long gas line is being installed in metallic pipe. The s...

[Show more]

Preview 3 out of 19  pages

  • July 30, 2024
  • 19
  • 2023/2024
  • Exam (elaborations)
  • Questions & answers
  • Maine Gas
  • Maine Gas
avatar-seller
ACADEMICMATERIALS
Maine Gas Exam - with codes A 10" natural gas main pipe is installed to supply a power plant; however, the pipe has a bad valve that must be replaced. How much of the 10" must be purged with inert gas before work can begin? - All of it NFPA 54 Table 8.3.1 A 127 foot long gas line is being installed in metallic pipe. The system is undiluted LP gas with an inlet pressure of 11.0 in w.c., with a 0.5 in. w.c. pressure drop and a specific gravity of 1.50. The appliance requires 1,670 cubic BTU of LP gas. What si ze metallic pipe should be installed? - 2" A 4" natural gas pipe must be purged with inert gas before servicing. What is the MAXIMUM length of pipe before purging is required? - Greater than 15 feet NFPA 54 8.3.1 A 520 foot long gas line is being installed in semi -rigid Type K copper tubing. The system is natural gas less than 2 psi, with a 0.3 in. w.c. pressure drop and a specific gravity of 0.60. The appliance requires 135 cubic feet of gas. What size tubing shou ld be installed? - 1-1/2" A building with roof -mounted, gas -fired equipment shall have a permanent inside means of access when the height of the building is more than.. - 15 feet in height NFPA 54 9.4.3.2 A commercial building has a 45 foot tall chimney with a total of 341,000 Btu input from one Category 1 natural draft vented appliance that has a Type B metal connector with a 10 foot lateral. What size masonry chimney is needed? - 8" A compressed natural gas (CNG) motor vehicle fueling facility shall be installed to meet which of the following standards? - NFPA 52 A factory has a 38 foot tall masonry chimney with a total of 962,000 BTU input from two Category I fan assisted vented appliances that have a single -wall metal connector with a two foot lateral. What size chimney is needed? - 9" A fuel -fired appliance is installed in a garage . What MINIMUM distance above the floor shall the source of burner ignition be located? - 18" NFPA 88 A gas supplied illuminating appliance shall be mounted on a post that is 6ft. What size post shall be installed to support the fixture? - 2-1/2" post, .064 thick steel, or 1" schedule 40 pipe NFPA 54 10.16.4 A house has a 19 foot tall chimney with a total of 185,000 BTU input from one Category I natural draft vented appliance that has a single -wall Metal connector with a 5 foot lateral. What size Type B chimney is needed? - 6" A large house is being built with one boiler 34 feet away from the meter that uses natural gas; all other appliances are electric. What size CSST stainless steel tubing should be installed to supply 220 cubic feet of natural gas per hour with an inlet pres sure less than 2psi, pressure drop of 0.5 in w.c. and a specific gravity of 0.60? - 37 A residential boiler or furnace with a listed gas conversion burner and draft hood with a type B gas vent shall have a minimum clearance from combustible materials of? - 6" NFPA 54 Table 12.8.4.4 A residential -type or low -heat appliance chimney shall terminate what MINIMUM distance above the highest point of the roof where they pass through? - 3 Feet NFPA 54 12.6.2.1 A service station is being built with one boiler 28 feet away from the meter that uses natural gas; all other equipment is electric. What size K or L semi -rigid copper tubing should be installed to supply 205 cu. ft. of gas per hour with an inlet pressure less than 2 psi, pressure drop of 0.3 in. W.C. and a specific gravity of 0.60? - 1 " A single -wall metal vent pipe, using a thimble to pass through a roof made of combustible material, shall be installed what MINIMUM distance above and below the roof? - 18" above and 6" below NFPA 54 12.8.4.5 All of the following piping materials are approved to be used for gas piping except... - Cast Iron NFPA 54 5.6.2.1 All steam and hot water boilers are required to have a pressure relief valve. All of the following are required for installation of the relief valve EXCEPT the... - discharge pipe shall drain into a sump tank An air conditioning system controls all of the following EXCEPT - Odor An appliance installed in an attic shall have a platform to service in front of the appliance. What is the MINIMUM size of the structure? - 30" X 30" NFPA 54 9.5.2

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller ACADEMICMATERIALS. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $7.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

74735 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$7.99
  • (0)
  Add to cart