LOW PRESSURE BOILER COF NY
A fill line in an oil burner system is a line used to: - answer- Fill the storage tank with oil.
The aquastat is located - answer- Below the water line.
All heating, combustion, and cooking equipment shall be installed with adequate
clearances from _______ construction. - answer- Combustible
The equipment must be provided with ______ or the building construction shall be
_____ _____. - answer- Insulation.
Fire Protected
During operation the surface of combustible construction materials will not be raised to
a temp higher than _____ degrees F. - answer- 170 degrees
Equipment shall be so that the means of access for ordinary operation and maintenance
will not be _______. - answer- Hazardous
Acceptance Tests:
Boilers shall not be placed in operation until they have been _____ and ____ and an
equipment ____ _____ has been issued by the ______. - answer- Inspected and tested.
Use permit, commissioner
Periodic Inspections: All boilers must be inspected at least _____ a _____ including
chimney connections. - answer- Once a year
Owners Annual Statement: The owner of each boiler shall file an _____ written
statement with the ________, specifying the _____of each boiler and ______ for
inspection. - answer- Annual, commissioner, location, arrangement.
Field Tests: all piping and oil storage tanks shall be _______ tested for tightness by the
______ before the system is operated. - answer- Hydrostatically, contractor
The piping shall be tested at _____ times the max working pressure applicable to that
part of the piping system but at a pressure ____ than the test pressure required for the
storage tank. - answer- 1/2, less
The min pressure for testing tanks shall be ____ times the max working pressure but in
no case less than ____ psi. - answer- 1 1/2, 25 psi
The hydrostatic pressure must be maintained until all ____ and _____ have been
visually inspected for ___, but in no case less than _____ hour. - answer- Joints,
connections, leaks, 1/2 hour.
, A record must be kept of the pressure test showing the name of the _____ and the
_____ at which the piping and tank were tested. - answer- Contractor, pressure
Gas piping must be tested by the _____ before operation. - answer- Contractor
For oil burning systems, ____ ____ giving instructions for the care and operation of the
system shall be permanently located in an easily _____ and _____ location near the
equipment. - answer- Instruction Cards, visible, accessible
No oil burning equipment shall be operated until an equipment ____ _____ has been
issued by the commissioner, the requirements of the ____ ____ control code have been
met and until the approval for the storage of ____ ____ has been given by the fire
commissioner. - answer- Use permit, air pollution, fuel oil
Every oil burning installation that is not fully automatic or requires preheating shall be
operated under the direct supervision of a person holding a ____ ___ ______ issued by
the FD. - answer- COF
Such person must be in the building at ____ ____ while in operation and present in the
_____ _____ during startup. - answer- All times, boiler room
After any repairs to the boiler are made, ______ shall check the repairs and the
functioning of all ____ _____ and the positioning of the ______. - answer- Operators,
control devices, valves
All heating and combustion equipment that is fired with solid, liquid, or gas fuels, must
comply with the requirements of the ____ _____ _____ code. - answer- Air pollution
control
Low Temp Equipment have a temp of ____ degrees at the point of leaving the
equipment. - answer- 600 or less
Median Temp Equipment have a temp of between ___ and ___ degrees F at the point
of leaving the equipment under normal conditions. - answer- 600 and 1000
High Temp Equipment have a temp of ____ or ____ degrees F leaving the equipment. -
answer- 1000 or greater
The air that contacts the oil prior to leaving the nozzle is called ____air. The introduction
of air from a blower or fan after the oil has left the nozzle is called _____ air. - answer-
Primary, secondary
Oil burners require approx _____ cubic feet of air per gallon of oil. Poor mixture could
become an _____ mixture. - answer- 2000, explosive
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller GEEKA. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for $12.49. You're not tied to anything after your purchase.