Exam (elaborations)
Nicet level 1 Study Guide questions with answers 2024
Nicet level 1 Study Guide questions with answers 2024
[Show more]
Preview 3 out of 19 pages
Uploaded on
August 3, 2024
Number of pages
19
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
Institution
Nicet
Course
Nicet
$13.49
Also available in package deal from $31.49
100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached
Also available in package deal (1)
1. Exam (elaborations) - Nicet fire alarm level 1 exam questions with answers
2. Exam (elaborations) - Nicet level 1 study guide questions with answers 2024
3. Exam (elaborations) - Nicet level 1 fire alarm exam 2024 with correct answers
4. Exam (elaborations) - Nicet level 1 fire alarm inspection & testing exam with correct answers
5. Exam (elaborations) - Nicet level 1 fire alarm systems exam questions with verified answers
Show more
Nicet level 1 Study Guide questions with
answers 2024
When mmtesting mma mmwater mmlevel mmsupervisory mmswitch mmserving mma mmpressure mmtank mma
mmsignal mmshall mmindicate mmif mmthe mmwater mmlevel mm_____________from mmthe mmrequired mmlevel
(NFPA mm72, mmTable mm14.4.3.2 mm17 mm(j) mm(4) mm- mmANSWER: mm mm➡ mmrises mmor mmfalls mmover mm3
mminches
If mmcombination mmaudible/visible mmappliances mmare mminstalled mmthe mmlocation mmof mmthe
mminstalled mmappliance mmshall mmbe mmdetermined mmby mmthe mmrequirements mmof mm_______.
(Nfpa mm72 mm18.4.8.1) mm- mmANSWER: mm mm➡ mmthe mmvisible mmappliance
What mmis mmthe mmmaximum mmnumber mmof mm12 mmgauge mmTHHN mmwires mmthat mmcan mmbe mminstalled
mmin mm1" mmEMT?
(Nec mmAnnex mmC mmtables) mm- mmANSWER: mm mm➡ mm26
Two mmresistors mmare mmconnected mmin mmparallel. mmR1 mm= mm300 mmOhms, mmR2 mm= mm300 mmOhms.
mmWhat mmis mmtheir mmequivalent mmresistance? mm- mmANSWER: mm mm➡ mm150 mmohms
A mmRoom mmis mm200' mmlong mmand mm150' mmwide mmand mmthe mm8' mmhigh mmceiling mmis mmsmooth mmand
mmflat. mmA mmspot mmtype mmheat mmdetector mmhas mmbeen mmselected mmthat mmis mmlisted mmfor mma mm50'
mmmaximum mmspacing mmbetween mmdetectors. mmAccording mmto mmNFPA mm72 mmhow mmmany
mmdetectors mmwill mmbe mmneeded mmto mmprotect mmthis mmroom?
200 mm/ mm50 mmx mm150 mm/ mm50 mm= mm- mmANSWER: mm mm➡ mm12
,According mmto mmNFPA mm72 mmthe mmminimum mmnumber mmof mmrestorable mmfixed mmtemperature
mmspot mmtype mmheat mmdetectors mmthat mmmust mmbe mmtested mmduring mmeach mmannual mmtest mmis?
mm(NFPA mm72 mm14.4.4.5.1) mm- mmANSWER: mm mm➡ mmTwo mmdetectors mmor mmmore mmon mmeach
mminitiating mmdevice mmcircuit
According mmto mmNFPA mm72 mmhow mmmany mmspot mmtype mmheat mmdetectors mmare mmrequired mmfor mma
mmspace mmthat mmis mm80' mmlong mmand mm55 mmfloor mmwide mmwith mma mmsmooth mm10' mmceiling? mmthe
mmdetector mmis mmlisted mmfor mma mmmaximum mmspace mmbetween mmdetectors mmof mm30' mm- mmANSWER:
mm mm➡ mm6
What mmcolor mmcode mmrequirement mmfor mma mmspot mmtype mmheat mmdetector mmrated mmat mm200゚F mm-
mmANSWER: mm mm➡ mmWhite mm(NFPA mm72, mmTable mm17.6.2.1)
Unless mmotherwise mmrecommended mmby mmthe mmmanufacturers mmpublished mminstructions
mmsingle mmand mmmultiple mmstations mmsmoke mmalarms mminstalled mmin mmone mmand mm2 mmfamily
mmdwellings mmshall mmbe mmreplaced mmevery mm- mmANSWER: mm mm➡ mm10 mmyears mmfrom mmthe mmday-of
mmmanufacture. mm(NFPA mm72, mm14.4.7.1)
Fire mmalarm mmcables mmare mmpermitted mmto mmbe mmstrapped mmto mmconduit mmto mmsupport mmthe
mmcable mm- mmANSWER: mm mm➡ mmFalse mm(NEC mm760.143)
Where mmnon mmpower mmlimited mmwiring mmis mminstalled mmexposed mmit mmmust mmbe mmmechanically
mmprotected mmwithin_____of mmthe mmfinished mmfloor mm- mmANSWER: mm mm➡ mm7' mmft
Fire-Warning mmequipment mmto mmbe mminstalled mmin mmresidential mmoccupancies mmshall mmproduce
mmthe mmaudible mmemergency mmevacuation mmsignal mmdescribed mmin mm- mmANSWER: mm mm➡ mmANSI
mmS3.41
According mmto mmNFPA mm72, mmvisible mmnotification mmappliance mmfor mmnon-sleeping mmareas mmmust
mmbe mmmounted mmbetween mm___ mmand mm___ mminches mmabove mmthe mmfinished mmfloor mm- mmANSWER:
mm mm➡ mm80 mm& mm96
, If mmsystem mmimpairment mmoccurs, mmthe mmowner mmmust mmbe mmnotified mm___ mmwithin mm___ mm-
mmANSWER: mm mm➡ mmin mmwriting mm& mmwithin mm24 mmhours
A mm20 mmX mm20' mmft mmroom mmwith mma mm20'ft mmhigh mmceiling mmrequires mmat mma mmminimum mma mm___
mmceiling mmmounted mmstrobe mm- mmANSWER: mm mm➡ mm30 mmcandela
According mmto mmNFPA mm72, mma mm40 mmx mm40'ft mmroom mmor mmarea mmwith mma mm10'ft mmceiling mmis
mmbest mmcovered mmby mma mm___ mmcd mmvisible mmnotification mmappliance, mmcentered mmon mmone mmwall.
mm- mmANSWER: mm mm➡ mm60
Conductors mmreturning mmto mmthe mmfire mmalarm mmcontrol mmpanel mm(FACP) mmfrom mmthe mmlast mmfield
mmdevice mmon mmthe mmcircuit mmmight mmindicate mma mm_____ mmcircuit mm- mmANSWER: mm mm➡ mmClass mmA
Secondary mmpower mmsupplies mmfor mman mmemergency mmvoice/alarm mmcommunication mmfire
mmalarm mmsystem mmshall mmbe mmcapable mmof mmoperating mmfor mmminimum mmof mm___ mmof mmstandby
mmfollowed mmby mm___ mmof mmalarm. mm- mmANSWER: mm mm➡ mm24 mmhrs mm& mm15 mmmins
The mmfire mmalarm mmsystem mmprimary mmpower mmbranch mmcircuit mmdisconnecting mmmeans mmmust
mmbe mm___ mmin mmcolor. mm- mmANSWER: mm mm➡ mmRed
The mmsecondary mmpower mmsupply mmfor mmprotected mmpremises mmshall mmautomatically mmprovide
mmpower mmwithin mm___ mmseconds mmwhen mmprimary mmpower mmfails. mm- mmANSWER: mm mm➡ mm10
mmseconds
Under mmwhich mmof mmthe mmfollowing mmconditions mmshall mmspot-type mmsmoke mmdetectors mmNOT
mmbe mminstalled? mm- mmANSWER: mm mm➡ mmWhen mmthe mmtemperature mmis mmover mm100*F
Who mmis mmresponsible mmfor mmmaintaining mmPersonal mmProtective mmEquipment? mm- mmANSWER: mm
mm➡ mmYOU, mmthe mmemployee
What mmdoes mmGFCI mmstand mmfor mm? mm- mmANSWER: mm mm➡ mmGround mmFault mmCircuit mmInterrupter