100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
Nicet level 1 Review Practice Exam Questions & Answers. $11.49   Add to cart

Exam (elaborations)

Nicet level 1 Review Practice Exam Questions & Answers.

 3 views  0 purchase
  • Course
  • Nicet
  • Institution
  • Nicet

Nicet level 1 Review Practice Exam Questions & Answers. When testing a water level supervisory switch serving a pressure tank a signal shall indicate if the water level _____________from the required level (NFPA 72, Table 14.4.3.2 17 (j) (4) - CORRECT ANSWER rises or falls over 3 inches ...

[Show more]

Preview 3 out of 17  pages

  • August 4, 2024
  • 17
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • nicet
  • Nicet
  • Nicet
avatar-seller
Nursewendo
Nicet level 1 Review Practice Exam
Questions & Answers.

When testing a water level supervisory switch serving a pressure tank a signal shall indicate if the water
level _____________from the required level



(NFPA 72, Table 14.4.3.2 17 (j) (4) - CORRECT ANSWER rises or falls over 3 inches



If combination audible/visible appliances are installed the location of the installed appliance shall be
determined by the requirements of _______.



(Nfpa 72 18.4.8.1) - CORRECT ANSWER the visible appliance



What is the maximum number of 12 gauge THHN wires that can be installed in 1" EMT?



(Nec Annex C tables) - CORRECT ANSWER 26



Two resistors are connected in parallel. R1 = 300 Ohms, R2 = 300 Ohms. What is their equivalent
resistance? - CORRECT ANSWER 150 ohms



A Room is 200' long and 150' wide and the 8' high ceiling is smooth and flat. A spot type heat detector
has been selected that is listed for a 50' maximum spacing between detectors. According to NFPA 72
how many detectors will be needed to protect this room?



x = - CORRECT ANSWER 12



According to NFPA 72 the minimum number of restorable fixed temperature spot type heat detectors
that must be tested during each annual test is?

,(NFPA 72 14.4.4.5.1) - CORRECT ANSWER Two detectors or more on each initiating device circuit



According to NFPA 72 how many spot type heat detectors are required for a space that is 80' long and
55 floor wide with a smooth 10' ceiling? the detector is listed for a maximum space between detectors
of 30' - CORRECT ANSWER 6



What color code requirement for a spot type heat detector rated at 200 ゚ F - CORRECT ANSWER White
(NFPA 72, Table 17.6.2.1)



Unless otherwise recommended by the manufacturers published instructions single and multiple
stations smoke alarms installed in one and 2 family dwellings shall be replaced every - CORRECT
ANSWER 10 years from the day-of manufacture. (NFPA 72, 14.4.7.1)



Fire alarm cables are permitted to be strapped to conduit to support the cable - CORRECT ANSWER False
(NEC 760.143)



Where non power limited wiring is installed exposed it must be mechanically protected within_____of
the finished floor - CORRECT ANSWER 7' ft



Fire-Warning equipment to be installed in residential occupancies shall produce the audible emergency
evacuation signal described in - CORRECT ANSWER ANSI S3.41



According to NFPA 72, visible notification appliance for non-sleeping areas must be mounted between
___ and ___ inches above the finished floor - CORRECT ANSWER 80 & 96



If system impairment occurs, the owner must be notified ___ within ___ - CORRECT ANSWER in writing
& within 24 hours



A 20 X 20' ft room with a 20'ft high ceiling requires at a minimum a ___ ceiling mounted strobe -
CORRECT ANSWER 30 candela



According to NFPA 72, a 40 x 40'ft room or area with a 10'ft ceiling is best covered by a ___ cd visible
notification appliance, centered on one wall. - CORRECT ANSWER 60

, Conductors returning to the fire alarm control panel (FACP) from the last field device on the circuit
might indicate a _____ circuit - CORRECT ANSWER Class A



Secondary power supplies for an emergency voice/alarm communication fire alarm system shall be
capable of operating for minimum of ___ of standby followed by ___ of alarm. - CORRECT ANSWER 24
hrs & 15 mins



The fire alarm system primary power branch circuit disconnecting means must be ___ in color. -
CORRECT ANSWER Red



The secondary power supply for protected premises shall automatically provide power within ___
seconds when primary power fails. - CORRECT ANSWER 10 seconds



Under which of the following conditions shall spot-type smoke detectors NOT be installed? - CORRECT
ANSWER When the temperature is over 100*F



Who is responsible for maintaining Personal Protective Equipment? - CORRECT ANSWER YOU, the
employee



What does GFCI stand for ? - CORRECT ANSWER Ground Fault Circuit Interrupter



A fixed-temperature, non-restorable spot type heat detector shall be tested ____ from initial
installation. - CORRECT ANSWER 15 years after



Heat detectors should be selected to operate at least ___ degrees Farenheit above the maximum
expected ambient temperature at the ceiling of the protected space. - CORRECT ANSWER 20*F



According to the NFPA 72, testing records of the fire alarm system shall be kept until the next test and
____ year thereafter. - CORRECT ANSWER 1



Who is responsible for storing and maintaining testing records of the fire alarm system? - CORRECT
ANSWER The Owner of the system

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller Nursewendo. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $11.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

79271 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$11.49
  • (0)
  Add to cart