100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
ABYC EXAM QUESTIONS AND ANSWERS 2024 $14.49   Add to cart

Exam (elaborations)

ABYC EXAM QUESTIONS AND ANSWERS 2024

 11 views  0 purchase
  • Course
  • Abyc
  • Institution
  • Abyc

Exam of 6 pages for the course Abyc at Abyc (ABYC EXAM)

Preview 2 out of 6  pages

  • August 5, 2024
  • 6
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • Abyc
  • Abyc
avatar-seller
Dreamer252
ABYC EXAM


require on all wet exhaust system - answeran indicator of loss of exhaust cooling water
is

1" - answerthe lowest point of a self-bailing cockpit sole shall be how high above the full
load water line

to prevent bilge pump cycling - answera check valve can be used in a bilge pump's
discharge line

length of discharge piping , number and radius of bends, and roughness of interior
surfaces of piping of fittings - answeras installed with a given head pressure, bilge pump
discharge capacity may be reduced by such factors as

when there is an enclosed accommodation compartment - answera high bilge water
alarm is required

a readily accessible manual switch is required - answerfor electric bilge pumps
installations that are equipped with an automatic switch

125 f - answera water system heater system must have a means of tempering the water
to

100 ppm - answeraccording to abyc a biologically contaminated portable water system
should be disinfected with a mixture of chlorine and water having a strength of at least

500 pounds - answerseacocks shall be installed so that the system will withstand a
static force of

a boat that meets level flotation performance criteria of abyc h8 - answerwhich of the
following would be exempted from requiring a seacock

be readily accessible - answerseacocks, when required, shall

seacock - answerabyc standards require that all piping, tubing or hose lines penetrating
the hull below the maximum heeled waterline be equipped with a

600 volts - answerwhen ax and dc conductors are run together or installed in the same
terminal box or enclosure on a generator, the dc conductors shall have a minimum
insulation voltage rating of

, 3% - answerconductors used for panelboard feeders navigation lights, bilge blowers
shall be sized for a voltage drop not to exceed

they must be rated for 2x the system voltage - answerwhich of the following is false
regarding galvanic isolators

sum of the rating of the main shore power disconnect circuit breakers - answerin dual
shore power cord application's using a single galvanic isolator, the current rating of the
galvanic isolator shall not be less than the

in a ventilated, dry, and accessible location - answerchargers and inverters shall be
installed

specified by the inverter manufacturer - answersince the operation of gfci devices is
dependent of the wave form of the AC source, GFCI devices installed in inverter output
circuits shall be

current and voltage - answerbattery chargers shall be selected and set, or adjusted, to
charge a battery or battery bank's at the appropriate

pass the 2-1/2 minute fire test - answerbattery chargers shall meet all of the following
requirements EXCEPT

point b - answerusing the diagram, when installing an inverter that is not ignition
protected aboard a vessel with gasoline inboard engines, the inverter should not be
located at

insolation transformer or shore power converter - answeraccording to ABYC A32, when
paralleling shore power and onboard power sources, the installation must include a/an

installed so as not to disturb water flow near intake and discharge fittings -
answeranodes used in cathodic protection systems shall be

at least 8 ga stranded copper wire, identified by the color green or green with a yellow
stripe - answercathodic bonding conductors may be

shall be bonded to the cathodic protection system - answerto minimize stray current
corrosion, metallic thru-hull fittings installed below the normal accumulation of bilge
water

-200mV - answeraccording to ABYC E-2, what is the minimum potential shift to achieve
full cathodic protection?

1 ohm - answerbased on ABYC E-2, the maximum acceptable resistance between the
protected metals in a bonding system and the sacrificial anode shall be no more than

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller Dreamer252. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $14.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

72042 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$14.49
  • (0)
  Add to cart