Helical ANS - ____ CT provides improved imaging of anatomy compromised by respiratory motion



chest

abdomen

pelvis ANS - what body parts is helical CT best for



Godfrey Hounsfield ANS - Who was the first to incorporate digital imaging with the CT scanner?



CT ANS - no other development in medical imaging over the past 50 years has been as significant as
_____



compton ANS - when the abdomen is imaged with conventional radiographic techniques, the image is
created directly on the IR and is low in contrast, principally because of _____ scatter radiation



neprotomography ANS - in _____ the renal outline is distinct because the overlying and underlying
tissues are blurred



tomosynthesis ANS - the latest advance in digital radiography is digital radiographic ____



axial tomography ANS - conventional tomography is called _____ because the plane of the image is
parallel to the long axis of the body; resulting in sagittal and coronal images



transverse ANS - a CT image is a transaxial or _____ image that is perpendicular to the long axis of the
body.



synchronously ANS - the X-ray source and the detector move ____ for CT

,translation ANS - when the source detector assembly makes one sweep, it is called ____



12 ANS - the detector signal during each translation has a dynamic range of ___ bits



5 minutes to complete image ANS - major drawback to first generation imaging system



first ANS - ____ generation imaging system: translate and rotate, pencil beam, single detector, 5 minute
imaging time



increased radiation intensity that occurs toward the edges of the beam because of body shape ANS -
major disadvantage of the fan beam in 2nd generation imaging system



speed ANS - what is the principal advantage of the second generation CT imaging system



second ANS - ____ generation imaging system: translate and rotate, fan beam, detector array, 30
second imaging time



examination time ANS - what is the principal limitation of 2nd generation CT imaging systems



occasional appearance of ring artifacts ANS - principal disadvantage of third generation CT imaging
system



third ANS - ____ generation imaging system: rotate and rotate, fan beam, detector array, sub second
imaging time



fourth ANS - ____ generation CT imaging system: rotate and stationary, fan beam, detector array, sub
second imaging time



third ANS - today essentially all CT imaging systems are ____ generation and have evolved into helical
and multislice imaging

,interpolation ANS - reconstruction of an image at any z axis position is possible because of a
mathematical process called ____



interpolation ANS - if one wishes to estimate a value between known values, it is ____



extrapolation ANS - if one wishes to estimate a value beyond the range of known values, it is ____



180 ANS - linear interpolation at ____ degrees improves z axis resolution



pitch = couch movement each 360 degrees / beam width ANS - equation for helical pitch ratio



ratio ANS - pitch is expressed as a ____



2:1 ANS - a pitch of ____ results in extended imaging and reduced patient radiation dose



1:1 ANS - increasing pitch to above ____ increases the volume of tissue that can be imaged at a given
time



ability to image larger volume of tissue in a single breath hold ANS - what is one advantage of multislice
helical CT



beam width x pitch x imaging time ANS - tissue imaged = _____



1.0 ANS - in practice, the patch for multislice helical CT is usually ____



1.0 :1 ANS - CT angiography requires a pitch of less than _____



operating console

generator

, xray tube ANS - what are the three major subsystems of conventional X-ray imaging system



operating console

computer

gantry ANS - what are the three major components of a CT imaging system



second ANS - the ____ monitor allows the operator to view images before transferring them to the
radiologist's viewing console



3 ANS - how many consoles can CT imaging systems be equipped with



120 ANS - operation is usually approximately ___ kVp, although some recent work supports reducing
patient dose by using a lower kVp



400 ANS - what is the maximum mA used



.5-5 ANS - nominal tissue thickness are ____ to ____mm



reconstruction time ANS - what do the microprocessor and the primary memory determine in CT



reconstruction time ANS - _____ is the time from the end of imaging to appearance of the image



array processor ANS - many CT imaging systems use an _____ instead of a microprocessor for image
reconstruction



xray tube

detector array

high voltage generator

patient support couch

mechanical support for each ANS - what 5 things make up the gantry

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller Professorkaylee. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $24.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

78252 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$24.49
  • (0)
  Add to cart