DEVICE RAC UPDATED Exam Questions and CORRECT Answers
3 views 0 purchase
Course
DEVICE RAC
Institution
DEVICE RAC
DEVICE RAC UPDATED Exam Questions
and CORRECT Answers
Which division would have primary jurisdiction over a vascular graft with an antibiotic based
on primary mode of action?
A. CDER
B. CBER
C. CDRH
D. OCP - Correct Answer- C
A company wants to modify its legally marketed device such that...
DEVICE RAC UPDATED Exam Questions
and CORRECT Answers
Which division would have primary jurisdiction over a vascular graft with an antibiotic based
on primary mode of action?
A. CDER
B. CBER
C. CDRH
D. OCP - Correct Answer- C
A company wants to modify its legally marketed device such that the modification does not
affect the intended use or alter the fundamental scientific technology of the device. If the
design outputs of the modified device meet the design input requirements, this change would
be best filed as a(n):
A. Special 510(k)
B. Abbreviated 510(k)
C. Traditional 510(k)
D. De novo 510(k) - Correct Answer- A
Under the statutory violations, failure to meet 510(k) requirements for a device that is
required to have a 510(k) and is in commercial distribution is considered to be:
A. Adulteration.
B. Improper use
C. Misbranded
D. Fraudulent - Correct Answer- C
A company's competitor is marketing a Class II suture which dissolves during the third week
of use. The company's current product has to be removed by a physician. However, a change
in weaving configuration gives this product the same dissolving time as the competitor's.
When can the company's new suture be marketed?
A. This requires a new 510(k) since significant change in product instructions might
,affect efficacy.
B. After submission in a periodic report
C. After reporting clinical studies in an annual report
D. After submission of labeling change - Correct Answer- A
Which of the following is exempt from GMP/QSR regulations?
A. Remanufacturers
B. Custom device manufacturers
C. Repackagers
D. Component manufacturers - Correct Answer- D
A physician reports to a manufacturer that a patient was hospitalized with acute sepsis after
treatment with an approved device. This side effect is not listed in the package insert. This
event must be reported by the manufacturer to FDA no later than:
A. 5 calendar days
B. 15 calendar days
C. 30 calendar days
D. The next quarterly or annual report - Correct Answer- C
If a device failure is occurring with greater than expected frequency and investigation of the
problem implicates improper use by the end user, which of the following typically occurs?
A. The labeling is revised.
B. The product is recalled.
C. The product is redesigned.
D. A "Dear Doctor" letter is issued. - Correct Answer- A
A handling and storage system for medical devices must always include:
A. Procedures for rotation of stock
B. Separate rooms or cages for release and quarantine products
C. Procedures for receipt and transfer of product
D. Environmentally controlled areas for products with shelf life - Correct Answer- C
, You have modified your 510(k) cleared device with a special 510(k). In which of the
following cases would you need to create a new listing for the device?
A. You have added new sizes and shapes in the product portfolio.
B. You have changed the material composition of the device.
C. You have changed the package of the device.
D. None of the above. - Correct Answer- D
According to the QSR, when an investigation of a complaint is conducted all of the following
are requirements for inclusion in the record of the investigation EXCEPT:
A. The dates and results of the investigation
B. The nature and details of the complaint
C. Changes in procedures correcting quality problems
D. Any reply to the complainant - Correct Answer- C
The QSR calls for the manufacturer of finished devices to carry out all of the following
EXCEPT:
A. Conduct quality audits by individuals who do not have direct responsibility for the
operation being audited
B. Audit operations annually
C. Document the dates and results of quality audits and re-audits
D. Have findings reviewed by management responsible for the matters audited - Correct
Answer- B
Which of the following subsystems is NOT required by FDA in order to implement and
maintain a Quality System?
A. Production and process controls
B. Test and control article characterization
C. Packaging and labeling controls
D. Facility and equipment controls - Correct Answer- B
According to the Quality System Regulations, re-testing and re-evaluation of nonconforming
devices after rework activities must be documented in the:
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller MGRADES. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for $9.49. You're not tied to anything after your purchase.