100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
EPA 608 TYPE 1 TEST ACTUAL EXAM 200 QUESTIONS AND CORRECT DETAILED ANSWERS WITH RATIONALES (VERIFIED ANSWERS) |ALREADY GRADED A+ Recovery equipemnt used for the service or repair of small appliances must be certified by an EPA approved lab if $24.49   Add to cart

Exam (elaborations)

EPA 608 TYPE 1 TEST ACTUAL EXAM 200 QUESTIONS AND CORRECT DETAILED ANSWERS WITH RATIONALES (VERIFIED ANSWERS) |ALREADY GRADED A+ Recovery equipemnt used for the service or repair of small appliances must be certified by an EPA approved lab if

 6 views  0 purchase
  • Course
  • EPA 608 TYPE 1
  • Institution
  • EPA 608 TYPE 1

EPA 608 TYPE 1 TEST ACTUAL EXAM 200 QUESTIONS AND CORRECT DETAILED ANSWERS WITH RATIONALES (VERIFIED ANSWERS) |ALREADY GRADED A+ Recovery equipemnt used for the service or repair of small appliances must be certified by an EPA approved lab if the recovery equipment was made after EPA 608 ...

[Show more]

Preview 3 out of 19  pages

  • August 9, 2024
  • 19
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • EPA 608 TYPE 1
  • EPA 608 TYPE 1
avatar-seller
Settings
EPA 608 TYPE 1 TEST 2023-2024 ACTUAL EXAM 200
QUESTIONS AND CORRECT DETAILED ANSWERS
WITH RATIONALES (VERIFIED ANSWERS) |ALREADY
GRADED A+
Recovery equipemnt used for the service or repair of small appliances must be certified by an EPA
approved lab if the recovery equipment was made after - ANSWER-November 15, 1993



Recovery devices made before 11-15-93 and are used for recovery of refrigerant from small appliances
must be capable of: - ANSWER-recovering 80% of the refrigerant whether or not the compressor is
operating or achieving a 4 inch vacuum under conditions of ARI 740-1993



EPA's definition of a small appliance includes: - ANSWER-a device manufactored, charges & hermeticly
sealed in factory with a charge of 5lbs or less



Tech's with a type 1 small appliance certification are certified to recover refrigerant during the
maintenance or repair of: - ANSWER-PTAC's with 5lbs or less of refrigerant



EPA requires that all small appliances be equipped with a service aperture or other device that is used
when adding or removing refrigerant from the appliance. For small appliances this service port typically -
ANSWER-a straight piece of tubing, called a process tube that is entered using a piercing valve



The EPA section 608 certification must be renewed every - ANSWER-never



It is an EPS regulation that any person who opens and appliance for maintenance, service or repair must
have at least one self-contained recovery machine avalible at their place of buisiness. The only exception
to this rule are persons working on - ANSWER-small appliances



The sale od CFC & HCFC refrigerants is: - ANSWER-restricted to techs who are EPA certified in refrigerant
recovery



Anyone who recovers refrigeration during maintenance, service or repair of small appliances must be
certified as either a universal Tech or a: - ANSWER-Type 1 tech

,When recovering refrigerant from a household refrigerator who's compressor does not run, it is
recommended that a low and high side access valves be installed because: - ANSWER-it can help speed
of recovery and required recovery effiency



If you install an access fitting into a sealed system: - ANSWER-the fitting should be leak tested before
proceeding with recovery



Before beginning a refrigerant recovery procedure it is alway necessary to: - ANSWER-determine the
type of refrigerant in the system



when recovering refrigerant into a non-pressurized container from a refrigerator with an improper
compressor: - ANSWER-it is necessary to heat & strike the compressor with a rubber mallet



When checking for the existence of noncondensable gases inside a recovery cyclinder, why is it proper
procedure to allow the temperature of the cyclinder to stabilize @ room temperature before taking a
pressure reading? - ANSWER-any comparisons to a pressure-temperature chart is only valid if both the
pressure & temperature of the refrigerant are stable



A recovery cyclinder which is 1/2 full of recovered R-410A @ 90*F, in the absence of non-condensables
will be presurized to: - ANSWER-300 psig.



When using ______, it is essential to take extra measures (heating/striking), to help release trapped
refrigerant from the compressor oil. - ANSWER-passive system-dependdent recovery devices on a small
appliance with a non-operating compressor.



According to the EPA which recovery equipment maintenance practice(s) should be preformed on a
regular basis? - ANSWER-check recovery device for refrigerant leaks



On a small appliance with an operating compressor that has a completely plugged capillary tube, what is
the minimum number of access valves that are needed to evacuate the refrigerant - ANSWER-1 valve on
the high side

, Which refrigerant is most commonly used as a replacement for R-12 in new household refrigerators -
ANSWER-R-134a



Small amounts of refrigerant have no odor, therefor a pungent odor is detected during a system
recovery &/or repair: - ANSWER-a compressor burn-out has likely occurred



If R-22 or R-12are exposed to high temperatures, these refrigerants can decompose to form: - ANSWER-
hydrochloric & hydroflouric acids



Large spills of refrigerant can cause suffocation because: - ANSWER-they are heavier than air & displace
oxygen



In the event of a large release of R-12 or R-22 in a contained area - ANSWER-you should wear a "SCBA"
or leave the area is required



If a large leak of refrigerant occurs in an enclosed area 7 no self-contained breathing apparatus is
available then you should - ANSWER-Vacate & ventilate the spill area



Portable refillable tanks or containers used to ship recovered refrigerants must meet what standards -
ANSWER-DOT



Recovery or recycling equipment whaich was manufactured after 11-15-93 and is used to recover
refrigerant from small appliances prior to the disposal of the small appliance must be used: - ANSWER-
recover 80% of the refrigerant if the compressor isn;t working and 90% on one with a working
compressor



EPA regulations require the capture of at least 80% of the refrigerant from a small appliance with an non
operating compressor is the tech is using: - ANSWER-either type of recovery unit



A standard vacuum pump designed for evacuation & dehydration can: - ANSWER-be only used as a
recovery device in combination with a non pressurized container

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller Settings. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $24.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

67474 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$24.49
  • (0)
  Add to cart