100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
UNEC 210 EXAM 2024/2025 WITH GUARANTEED ACCURATE ANSWERS |VERIFIED $13.99   Add to cart

Exam (elaborations)

UNEC 210 EXAM 2024/2025 WITH GUARANTEED ACCURATE ANSWERS |VERIFIED

 1 view  0 purchase
  • Course
  • UNEC 210
  • Institution
  • UNEC 210

In a dwelling unit, at least one lighting outlet _____ shall be located at the point of entry to the attic, underfloor space, utility room, or basement where these spaces are used for storage or contain equipment requiring servicing. - ACCURATE ANSWERcontrolled by a wall switch containing a switch...

[Show more]

Preview 3 out of 21  pages

  • August 9, 2024
  • 21
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • UNEC 210
  • UNEC 210
avatar-seller
GRADEUNITS
UNEC 210 EXAM 2024/2025
UNEC 210 EXAM 2024/2025 WITH GUARANTEED ACCURATE ANSWERS |VERIFIED




In a dwelling unit, at least one lighting outlet _____ shall be located at the point of
entry to the attic, underfloor space, utility room, or basement where these spaces
are used for storage or contain equipment requiring servicing. - ACCURATE
ANSWER✅✅controlled by a wall switch
containing a switch
210.70(A)(3)


An individual 20A branch circuit can supply a single dwelling unit bathroom for
receptacle outlet(s) and other equipment within the same bath-room. - ACCURATE
ANSWER✅✅True
210.11(C)(3) Ex


GFCI protection shall be provided for all 15A and 20A, 125V, single-phase
receptacles in dwelling unit unfinished portions or areas of basements not intended
as habitable rooms. - ACCURATE ANSWER✅✅True
210.8(A)(5)

,Ground-fault circuit-interrupter protection shall be provided for outlets not
exceeding 240V that supply boat hoists installed in dwelling unit locations. -
ACCURATE ANSWER✅✅True
210.8(C)


Receptacle outlets in meeting room fixed walls shall be installed in accordance
with _____. - ACCURATE ANSWER✅✅210.52(A)(1) through (A)(4)
210.71(B)(1)


Where branch-circuit wiring in a dwelling unit is modified, replaced, or extended
in any of the areas specified in 210.12(A), the branch circuit shall be protected by a
_____. - ACCURATE ANSWER✅✅a or b
210.12(D)


If a 20A branch circuit supplies multiple receptacles, the receptacles shall have an
ampere rating of no less than _____. - ACCURATE ANSWER✅✅15A
210.21(B)(3) and Table 210.21(B)(3)


Where a portion of the dwelling unit basement is finished into one or more
habitable rooms, each separate unfinished portion shall have a receptacle outlet
installed. - ACCURATE ANSWER✅✅True
210.52(G)(3)


All single-phase receptacles rated 150V to ground or less, 50A or less and three-
phase receptacles rated 150V to ground or less, 100A or less installed _____ of
commercial occupancies shall have GFCI protection. - ACCURATE
ANSWER✅✅all of these
210.8(B)(1), (2), and (3)

, All single-phase receptacles rated 150V to ground or less, 50A or less and three-
phase receptacles rated 150V to ground or less, 100A or less installed in locker
rooms with associated showering facilities shall be GFCI protected. - ACCURATE
ANSWER✅✅True
210.8(B)(7)


Receptacle outlets can be installed below the countertop or work surface in
dwelling units when necessary for the physically impaired, or if there is no means
available to mount a receptacle above an island or peninsular _____ in. above the
countertop or work surface. - ACCURATE ANSWER✅✅20
210.52(C)(5) Ex


In other than dwelling locations, GFCI protection is required for all single-phase
receptacles rated 150V to ground or less, 50A or less and three-phase receptacles
rated 150V to ground or less, 100A or less in unfinished portions or areas of the
basement not intended as habitable rooms. - ACCURATE ANSWER✅✅True
210.8(B)(10)


A receptacle outlet shall be installed at each dwelling unit kitchen wall countertop
and work surface space that is 12 in. or wider and receptacle outlets shall be
installed so that no point along the wall line is more than _____ in., measured
horizontally from a receptacle outlet in that space. - ACCURATE
ANSWER✅✅24
210.52(C)(1)


The receptacle outlet for a dwelling unit bathroom shall be located on a _____
adjacent to the basin or basin countertop, on the countertop, or on the side or face
of the basin cabinet, and never more than 12 in. below the top of the basin or basin
countertop. - ACCURATE ANSWER✅✅a or b

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller GRADEUNITS. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $13.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

75860 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$13.99
  • (0)
  Add to cart