ARMY ELECTRICAL EXPLOSIVES SAFETY (AMMO-28)
Which two publications provide detailed information on lightning protection systems? -
answer- DA PAM 385-64
NFPA 780

Which statements about lightning protection are true?Select all that apply. - answer-
Lightning can detonate munitions and explosives.

Lightning seeks the path of least resistance to ground.

Lightning cannot be stopped or prevented.

Which statement is true about a mast LPS? - answer- Each mast must have two paths
to ground.

A 30-foot tall building is protected by a catenary system. How far from the building
should the masts be placed? - answer- at least 6 feet

Which LPS uses air terminals and conductors mounted directly to the structure? -
answer- Integral

Why does the wooden mast have an air terminal on top and two down conductors
running its entire length? - answer- The wooden mast is not electrically conductive

Which of the following is NOT a requirement for air terminals? - answer- Air Terminals
must be at least 6 feet tall.

During the inspection, John's team logged a discrepancy for this air terminal. Why? -
answer- The air terminal is not attached to a conductor.

How many down conductors are required for a building with a perimeter length of 325
feet? - answer- 4

While conducting an LPS inspection, you see mast down conductors routed as shown in
the image below. Do you write it up as a discrepancy? Why or why not? - answer- Yes,
because mast down conductors should be 180 degrees apart.

A steel beam, connected to the main LPS at its upper and lower extremities, is used as
a down conductor. At what intervals should it be connected to the grounding system? -
answer- 60 feet or less

Which statement about grounding systems is true? - answer- The resistance should be
25 ohms or less.

, Which of the following statements regarding bonding are true? Select all that apply. -
answer- Bonding reduces the threat of sideflash by providing a low impedance path to
ground.

Bonding is a way of connecting LPS conductors to grounded metal objects.

How often is a bonding resistance test required on an LPS? - answer- Every 24 months

What is the maximum allowable reading for a bonding resistance test on an LPS
conductor? - answer- 1 ohm or less

When conducting a bonding resistance test on an integral LPS with 10 air terminals and
two down conductors, how many individual resistance tests are required, at a minimum?
- answer- 20

While conducting a bonding resistance test on the integral LPS below, you placed test
leads on ground rod S and air terminal N. Which three bonds listed below are NOT
being tested? - answer- B
H
P

What information should be in a destructive weather plan? Select all that apply. -
answer- Which operations to shut down

Who is responsible for shutting down each operation

Steps for shutting down each operation

Instructions for evacuating personnel

Instructions for restarting each operation

Spheric - answer- Detects lightning strike

Alerts when lightning is nearby

Pre-strike - answer- Measure the strength of atmospheric electric fields

Alerts when lightning strikes are imminent

What is the primary danger in a hazardous classified location? - answer- Explosive
atmosphere

Which division describes a hazardous classified location with greatest probability of
ignition or explosion? - answer- Division 1

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller GEEKA. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $10.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

77254 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$10.99
  • (0)
  Add to cart