100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
Residential Wireman Electrical Exam - Larry Bobo With complete solution | Latest 2024/25 RATED A+Residential Wireman Electrical Exam - Larry Bobo With complete solution | Latest 2024/25 RATED A+ $12.49   Add to cart

Exam (elaborations)

Residential Wireman Electrical Exam - Larry Bobo With complete solution | Latest 2024/25 RATED A+Residential Wireman Electrical Exam - Larry Bobo With complete solution | Latest 2024/25 RATED A+

 3 views  0 purchase
  • Course
  • Residential Wireman Electrical
  • Institution
  • Residential Wireman Electrical

Residential Wireman Electrical Exam - Larry Bobo With complete solution | Latest 2024/25 RATED A+

Preview 2 out of 10  pages

  • August 15, 2024
  • 10
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • Residential Wireman Electrical
  • Residential Wireman Electrical
avatar-seller
STUVATE
Residential Wireman Electrical Exam -
Larry Bobo With complete solution |
Latest 2024/25 RATED A+
The minimum size equipment grounding conductor for a 100 ampere, 120/240 volt
single phase underground dwelling feeder whose ungrounded conductors have been
increased in size from 3 AWG copper to 1 AWG copper is __ AWG copper

Ampacities, Grounding
250.122(B) Table 250.122 Table 8 Ch 9 - 4

The continuity of the grounded conductor shall depend on a busbar or __ only.

Continuity, Grounded conductors
200.12 - wire.

Each multi-wire branch circuit shall be provided with a means that will ____ disconnect
all ungrounded conductors at the point where the branch circuit originates.

Disconnecting means, Branch circuits, multiwire 210.4(B) - Simultaneously

Balconies, decks, and porches that are accessible from the inside of the dwelling unit
shall have at least one receptacle not more than __ ft. above the balcony, deck, or
porch surface.
Balconies, outdoor, receptacles for,
210.52(E)(3) - 6 1/2

Where it is impracticable to locate the service head above the point of attachment, the
service head location shall be permitted not farther than ___ inches from the point of
attachment.
Service drops, Connections, service head
230.54 (C) Exception - 24

True/False: One of the means by which grounding conductors and bonding jumpers
shall NOT be connected by is machine screw type fasteners.

Connection of Grounding and Bonding Equipment 250.8 - False

Cables with entirely nonmetallic sheaths are permitted to enter the top of a surface-
mounted enclosure through one or more nonflexible raceways not less than 450 mm (18
in.) and not more than __ feet in length

Cabinets, Cutout Boxes, and Meter Socket Enclosures. 312.5(C) - 10

, The maximum allowable overcurrent protection for four 14/2 NM cables installed in
contact with thermal insulation without maintaining spacing between cables is:

Nonmetallic-sheathed cable, Insulation, Ampacity,
334.112, 334.80 - 15

What kind of protection is required for an outdoor receptacle located under the soffit of
a dwelling for holiday lighting?

Ground-fault circuit interrupters, Outdoors, dwelling units,
210.8(A)(3) - GFCI

The minimum rating for a service disconnecting means for a building, other than a
single family dwelling, consisting of three 2 wire circuits shall be__ amperes.

Service equipment, Rating,
230.79(D) - 60

Where ungrounded conductors are increased in size, equipment grounding conductors
shall be increased in size ___.

Grounding conductors, 250-III, Sizes, 250.122 250.122(B) - proportionately

True/ False: Unless listed for the control of other loads, general use dimmer switches,
shall only be used to control permanently installed incandescent luminaires.

Dimmers, Switch
404.14(E) - True

In what areas of a dwelling shall 125-volt, single phase, 15 and 20 ampere outlets not
be required to be protected by an arc-fault circuit interupter? Dwellings, Arc-fault circuit-
interrupter protection, 210.12(A) 210.12(A) - Hallways

A ground ring encircling the building or structure, in direct contact with the earth, shall
consist of at least 20 feet of bare copper conductor NOT smaller than __ AWG.

Ground ring
250.52(A)(4) - 2

The minimum size copper equipment grounding conductor required for a 15-ampere
branch circuit installed in rigid metal conduit that supplies a swimming pool pump motor
is __ AWG.

Swimming pools, fountains, and similar installations, 680.21(A)(1) - 12

The maximum allowable ampacity of 18 AWG fixture wire is _ amperes.

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller STUVATE. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $12.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

77016 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$12.49
  • (0)
  Add to cart