100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
Michigan Builders License Exam QBank | 757 Questions and Answers/ VERIFIED/ $13.49   Add to cart

Exam (elaborations)

Michigan Builders License Exam QBank | 757 Questions and Answers/ VERIFIED/

 9 views  0 purchase
  • Course
  • Michigan builders license
  • Institution
  • Michigan Builders License

Michigan Builders License Exam QBank | 757 Questions and Answers/ VERIFIED/ Created to serve as a complete, comprehensive code regulating the construction of single-family, two-family and buildings consisting of three or more townhouse units. - ANSWER IRC (International Residential Code) Admini...

[Show more]

Preview 4 out of 83  pages

  • August 17, 2024
  • 83
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • Michigan builders license
  • Michigan builders license
avatar-seller
Nurslink
Michigan Builders License Exam QBank | 757
Questions and Answers/ VERIFIED/2024-2025
Created to serve as a complete, comprehensive code regulating the construction ofsingle-family,
two-family and buildings consisting of three or more townhouse units. - ANSWER IRC
(International Residential Code)

Administrative - ANSWER First 2 chapters of code book are

True - ANSWER Plans or supporting documents are almost always required bythe
controlling authority prior to issuing a permit. T or F

Yes - ANSWER Does the building official have the authority to render
interpretations of the code?

8 foot fence. - ANSWER None of the following require a permit, EXCEPT:

sidewalks and driveways

tiling

an 8 foot fence

playground equipment

False - ANSWER Tables and illustrations are always supported by information found in
the written code and footnotes. T or F

Live load. - ANSWER The amount of evenly distributed weight imposed by inhabitants,
goods and removable objects on a floor or roof system is referred toas

True. - ANSWER If a code requirement is in the book, it is both acceptable and
enforceable by the code official. T or F

Figures. - ANSWER Illustrations are typically referred to as

Determine that buildings are built to the minimum enforceable standard. -ANSWER
Generally speaking, the building official's job is to

True. - ANSWER It is required that all manufacturer instructions be at the jobsiteat the time
of inspection. T or F

Kitchen. - ANSWER All of the following are not considered habitable spacesEXCEPT:

,bathrooms

kitchens storage

spacesclosets

3. - ANSWER Bathrooms must be provided with an aggregate glazing area no lessthan
square feet, half of which must be openable.

44 inches. - ANSWER The maximum height of an egress window above the flooris

5.7 sq ft. - ANSWER A basement bedroom must have an egress window with aclear
opening of at least square feet.

3. - ANSWER At least one side-hinged exit door must be in each dwelling unit,and must
be feet wide.

30 inches. - ANSWER A porch more than inches above grade must be
provided with 36" guards.

200. - ANSWER Wall and ceiling finishes shall have a flame-spread classificationof no more
than .

7 days. - ANSWER According to code, concrete must reach at least 70% of it'sability
within days.

40%. - ANSWER A stud used for a non-bearing partitions may not be notchedmore than
% of the stud width.

Additions, alterations, renovation and repairs. - ANSWER The Michigan Uniform
Energy code applies to new buildings as well as

U-factor. - ANSWER is a measure of how well the window or door assembly
conducts heat. The lower the number, the better insulation the assemblywill provide.

50%. - ANSWER Energy losses from recessed lighting fixtures can often reach
% of the total thermal loss of a ceiling.

R-3. - ANSWER Michigan requires a minimum thermal resistance of
for mechanical system piping.

,True. - ANSWER Oversized HVAC equipment has a higher initial cost, a higheroperating
cost, provides less comfort, and shorter life expectancy. T or F

Prescriptive Path. - ANSWER is the compliance route that applies Table
402.1.1 to building envelope components, and is considered the most simple.

Area weighted averages. - ANSWER can be used to satisfy U-factorand
SHGC requirements.

IC (Insulation Contact) - ANSWER Recessed lights must be rated.

True. - ANSWER Up to 15 square feet of glazing per dwelling unit is exemptedfrom U-
value requirements. T or F

Registered design professional. - ANSWER The 2009 IECC requires a permanent
certificate posted on the electrical distribution panel. The certificate shall be completed by the
builder or

State energy code requirements. - ANSWER One hurdle contractors face when
bidding for an energy efficient project is choosing materials that fit the design, and also
meet

False. - ANSWER Historically significant buildings are not exempt from codechanges. T
or F

R-value

Settled thickness

Manufacturer name - ANSWER Insulation products (blown and sprayed) must be
documented with:

March 2011. - ANSWER The new Michigan codes took effect in

10. - ANSWER Below grade walls are insulated from the top of the basement walldown to
below grade, or the basement floor, whichever is less.

Area weighted average. - ANSWER The is the combined Solar Heat Gain
Coefficient of all the glazed fenestration products in the building.

Thermal insulation R-values

Design criteria

Equipment systems - ANSWER Plans and specifications must be detailed inregards
to:

, 2009. - ANSWER In Michigan, the residential energy code is based on the
IECC, with certain amendments.

Air leakage. - ANSWER is the rate of air infiltration in the presenceof a
specific pressure differential.

Windows

Attic access hatches

Recessed lights - ANSWER Air leakage is the random movement of air into andout of
through cracks and holes.

Table 402.1.1

2009 IECC - ANSWER R-values for insulation and fenestration requirements by
component can be found in

International Energy Conservation Code - ANSWER IECC

U-factor and UA alternatives. - ANSWER The compliance method
allows for more innovative construction techniques like SIPs or Advanced Framing.

500 sq feet - ANSWER R-30 is permitted in vaulted ceilings, but is limited to

True. - ANSWER Floor insulation must be installed to maintain permanent andcontinuous
contact with the underside of the subfloor decking. T or F

5, 6 and 7. - ANSWER Michigan falls into climate zones

False. - ANSWER It is permissible for supply ducts to be run through the framingcavities of
a residential building. T or F

IC rated (Insulation Contact) - ANSWER means an electrical fixture has
been tested and listed as suitable for installation in a cavity where the fixturemay come in
contact with insulation.

3%. - ANSWER According to the Dept. of Energy, improved energy codes couldreduce
CO2 emissions by

300 sq ft. - ANSWER Attic insulation markers must be installed every
square feet.

True. - ANSWER Buildings that are exempted from the new regulations are thosewith very
low energy use or ones that are neither heated or cooled. T or F

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller Nurslink. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $13.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

62890 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$13.49
  • (0)
  Add to cart