100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
ARMRIT Practice Questions and Answers 2024 $17.49   Add to cart

Exam (elaborations)

ARMRIT Practice Questions and Answers 2024

 8 views  0 purchase
  • Course
  • ARMRIT
  • Institution
  • ARMRIT

Exam of 7 pages for the course ARMRIT at ARMRIT (ARMRIT Practice)

Preview 2 out of 7  pages

  • August 17, 2024
  • 7
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • ARMRIT
  • ARMRIT
avatar-seller
jw638729
ARMRIT Practice


Nuclear magnetic resonance. - answerMagnetic Resonance Imaging is derived from the
process known as:

Magnetic field, proton, radio-wave - answerOn a very basic level, the three basic
components required to attain MR signals are:

Superior soft-tissue contrast resolution. - answerIn comparison to Computed Axial
Tomography, an advantage of MRI is:

Special and costly site planning and shielding. - answerIn comparison to Computed
Axial Tomography, a disadvantage of MRI is:

Iron, cobalt, nickel. - answerMagnetism can be defined as the ability of certain
substances to attract:

Field or flux - answerTo symbolize the flow and area of a magnetic field, lines are used
which are called:

Dipoles. - answerMagnetic fields have direction which are usually designated as north
and south, therefore
magnetic fields are described as:

Vector. - answerMagnetic fields have strength and direction, which are represented by
a:

Faraday's Law - answerIn a loop of conductor in which an electric current is introduced
and maintained, a magnetic
field will be produced in the center perpendicular to the flow of electric current. This is
called:

Tesla. - answerThe strength of very large magnetic fields like those employed in MRI
systems, the SI unit
most commonly used is:

15,000 gauss - answerA 1.5 Tesla magnetic field is equal to:

0.06 Tesla to 3 Tesla - answerIn the USA, MRI systems in clinical use have main
magnetic field strengths that range
from:

, Homogeneity. - answerTo describe the uniformity of the MRI system's main magnetic
field, the term employed is:

B0 - answerIn the USA, the MRI system's main magnetic field and the vector that
represents it is
symbolized:

20-30 PPM. - answerThe main magnetic field of MRI systems in clinical use must meet
an acceptable
specification of:

H2O - answerAt any one time, human body tissue, in general, is made up of 50 - 90% of
what substance?

Odd number of total protons and neutrons. - answerIn MR imaging, for a chemical
substance to be affected by the main magnetic field and the
radio-wave it must contain an:

H - answerIn clinical MR imaging of the human body, the substance of interest is:

Magnetic moment - answerBecause of the spinning motion of the hydrogen proton it
has the same properties as a bar
magnet. The hydrogen proton's spinning motion gives it a:

Resonance frequency - answerIn MRI, substances respond to a specific radio
frequency which is known as:

Larmor equation - answerThe resonance frequency of any substance in a magnetic field
can be calculated by
employing the:

Gyro-magnetic ratio - answerAll chemical substances have an assigned constant known
as the:

wo = y x Bo - answerWhich of the following is the Larmor equation?

Wavelength and frequency - answerA sinewave is a symbol used to measure
electromagnetic energy. A sinewave's two components of measurement are:

permanent - answerWhich type of MRI magnet is made up of naturally ferromagnetic
material?

resistive - answerWhich type of MRI magnet requires a steady current of electricity in
coils of conductor wrapped around an air or iron core?

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller jw638729. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $17.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

75632 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$17.49
  • (0)
  Add to cart