Different tissues that have signals that appear similar on an MR image are described
as: - answer isointense

in a large main magnetic field such as those employed in MRI, the motion of a hydrogen
proton has been described as wobbling like a spinning top. this motion is called -
answer precession

magnetic resonance imaging is derived from the process known as: - answer nuclear
magnetic resonance

Once the nmv (Net Magnetization Vector) has moved away from equilibrium, the
following will occur. - answer the transverse component will increase

In MR, substances respond to a specific radio frequency which is known as: - answer
resonance frequency

the introduction of gadolinium-based contrast enhancement agents by intravenous
injection can involve passing through an abnormal blood brain barrier. the tissue
compartments involved are the: - answer intravascular to interstitial

T2 is the measurement of time for the transverse component of the NMV to decrease
what percentage of its maximum value after the application of a 90 degree radio-
frequency pulse - answer37%

in the USA, the MRI system's magnetic field and vector that represents it is symbolized:
- answerB0

The resonance frequency of any substance in a magnetic field can be calculated by
employing the - answerLarmor equation

in a pulse sequence, transmitting an initial 90 degree radio-frequency pulse will cause
the NMV to: - answershift in both size and direction

Which type of electromagnetic coils are designed to stimulate and detect an MR signal?
- answerradio frequency coils

tissues that are less efficient at spin-spin interactions because they contain more free
water, such as CSF, should have - answerHigh T2 values and produce hyperintense
signals

,magnetism can be defined as the ability of certain substances to attract: - answerIron,
cobalt, nickel

the purpose of magnetic resonance angiography is to image the: - answerblood flow

the strength of very large magnetic fields like those employed in MRI systems, the SI
unit most commonly used is: - answerTesla

the larmor frequency of hydrogen protons in a 1.5 tesla magnetic field is: - answer63.9
MHz/Tesla

In MR imaging, for chemical substance to be affected by the main magnetic field and
the radio-wave it must contain an: - answerOdd number of total protons and neutrons

A 1.5T magnetic field is equal to: - answer15,000 gauss

the components of the gyromagnetic ratio are: - answermagnetic moment to angular
momentum

fast transition phenomenon and entry phenomenon are theories that explain which of
the following characterisitics: - answerVelocity effects

the effects of main magnetic field inhomogeneities on the FID signal are corrected for in
the spin echo sequence by applying a second radio frequency pulse. the flip angle of
this radio frequency pulse is: - answer180 degrees

of the following statements, which describes part of the basic MR imaging process: -
answerradio frequency signals interact with hydrogen protons

which type of electromagnetic coils correct inhomogeneities in the main magnetic field?
- answershim coils

immediately after an initial 90 degree radio frequency pulse is turned off, the hydrogen
protons will begin to: - answerDephase

tissues that are very efficient at spin-lattice interactions near the larmor frequency, such
as fatty tissues should have: - answerLow T1 values and produce hyperintense signals

T1 is the measurement of time for the longitudinal component of the NMV to recover
what percentage of its original value after the application of a 90 degree radio frequency
pulse? - answer63%

the tissue characteristic which depends more on the state (solid, liquid, gas) of a tissue
than any other factor is: - answerT2 effects

, the basic process of MR signal generation contains 2 basic steps, they are: -
answerstimulation and relaxation

the T1 process is also known as: - answerspin lattice

the T2 process is also known as: - answerspin spin

once in the main magnetic field, a majority of hydrogen protons will align themselves -
answerParallel to B0

the tissue characteristic that depend heavily on the relative content of fat molecules and
free water is: - answerT1 effects

which type of receiver radio frequency coil is placed close to a patient's body for the
purpose of imaging superficial anatomic structures - answersurface coils

an equation derived to predict the MR signal intensity of a particular tissue as the result
of a spin echo pulse sequence is the: - answerlarmor equation

which statement is true of the relaxation process? - answerwithout the effects of T2*, T2
decay continues

because of the spinning motion of the hydrogen proton it has the same properties as a
bar magnent. the hydrogen protons spinning motion gives it a - answermagnetic
moment

On a proton density image, 2 types of tissue that contain very low concentrations of
hydrogen and appear very hypointense are - answercerebral tissue and CSF

in comparison to CT an advantage of MRI is: - answersuperior soft tissue contrast
resolution

in a loop of conductor in which an electric current is introduced and maintained a
magnetic field will be produced in the center perpendicular to the flow of the electric
current. this is called: - answerFaraday's Law

which type of MRI magnet has attainable field strengths of 0.35T to 3T for clinical use in
the USA and higher strengths elsewhere and in research? - answersuperconductive

the process of relaxation begins when: - answerB1 is turned off

a sinewave is a symbol used to measure electromagnetic energy. A sinewave's 2
components of measurement are: - answerwavelength and frequency

magnetic fields have direction which are usually designated as north and south
therefore magnetic fields are described as: - answerdipoles

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller jw638729. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $12.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

79373 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$12.49
  • (0)
  Add to cart