In order for an x-ray photon to be measured it must:
1. enter the detector chamber
2. be absorbed by the detector material
3. be converted to a measurable event - correct answer...1,2,3
Which system component converts the ...
CT Registry Review (MIC) Questions
With Correct Answer 100%Verified
In order for an x-ray photon to be measured it must:
1. enter the detector chamber
2. be absorbed by the detector material
3. be converted to a measurable event - correct answer...✔✔1,2,3
Which system component converts the projection attenuation data into the proper digital
form for the array processor? - correct answer...✔✔analog-to-digital converter
Which of the following is NOT a function of a PACS system?
a. reconstruction of the image from the raw data
b. long term data storage
c. digital distribution of images
d. image display for the radiologist - correct answer...✔✔reconstruction of the image
from raw data
Which of the following is not part of the CT tube?
a. tungsten target
b. collimator
c. rotating anode
d. filament - correct answer...✔✔collimator
Which of the following is FALSE regarding CT systems?
1. they are limited to nonoblique transverse scanning
2. they cannot generate a straight coronal or sagittal image
3. hey have no moving parts - correct answer...✔✔1,2,3
Xrays are used in CT because:
a. they are easily produced by the high frequency generator
b. they are less harmful than the heating effects of microwave radiation
c. they penetrate the body according to specific attenuation characteristics of each
tissue
d. the FDA imposes no limit on the dose to the patient - correct answer...✔✔C
Most of the commands from the technologists are received by the: - correct answer...✔
✔operators console
Xrays are produced whenever fast moving electrons collide with any form of matter
because: - correct answer...✔✔The electron loses kinetic energy which is converted
into the emission of an x-ray photon
AGRADESOLUTIONS
,The mA determines the: - correct answer...✔✔quantity of x-ray photons
Which of the following is a component NOT normally located in the gantry of a modern
CT system? - correct answer...✔✔array processor
Tube interscan delay time refers to: - correct answer...✔✔the time between the end of
one scan and the start of the next scan during which the tube will cool
Increased _______ will increase the likelihood that a given x-ray will penetrate a
material
1. kV
2. mA
3. exposure time - correct answer...✔✔1
Which of the following are NOT commonly used on today's commercially available CT
scanners?
1. xenon detectors
2. fourth-generation technology
3. continous rotation technology - correct answer...✔✔1,2
Which of the following statements is FALSE regarding occurrences after an x-ray
photon penetrates the detector aperture?
1. the photon can pass through the detector unmeasured
2. the photon is converted completely into a electron
3. the measured signal in enhanced by an amplifier - correct answer...✔✔2
Scatter radiation is caused by: - correct answer...✔✔deflections from the original
trajectory of an x-ray photon through the patient
What control does the operator have over the x-rays in a CT exam? - correct answer...
✔✔the energy level and the quantity of x-rays can be selected
Which of the following is the standard that's used to achieve compatibility for image
transfer between various imaging modalities, viewing stations, and printers in a
hospital? - correct answer...✔✔DICOM
The enormous heat that builds up in the CT tube is caused by what? - correct answer...
✔✔Collision of the electron beam with the tungsten target on the tube anode
_________________ made helical imaging possible - correct answer...✔✔Continuous
rotation scanners
The patient table:
a. may move continuously during the scan
b. can never be positioned automatically by software due to safety precautions
AGRADESOLUTIONS
,c. remains stationary through the exam once it is initially positioned
d. only moves after each slice is completed - correct answer...✔✔A
The main purpose of the detector is to: - correct answer...✔✔capture x-ray photons
and convert them to a measurable signal
The cathode filament: - correct answer...✔✔helps determine the size of the focal spot
Which of the statements in TRUE:
1. kV is the voltage potential between the tube cathode and anode while mA ultimately
controls the filament temp of the cathode filament
2. kV controls the energy level of the x-ray photons and mA controls the number of x-ray
photons emitted from the tube
3. although kV and the mA affect the operation of the CT x-ray tube, the two parameters
have no bearing on the image quality - correct answer...✔✔1,2
The number of electrons that flow from the cathode to the anode is controlled by the: -
correct answer...✔✔mA
Which of the following is TRUE regarding solid state detectors:
1. x-ray photons cause the detectors to generate a flash of light
2. they are the detector type used on most CT scanners
3. they can be used in both third-generation and fourth-generation CT systems - correct
answer...✔✔1,2,3
The slip ring on continous rotation CT scanners:
1. prevent the high voltage cable from winding up
2. allows the exam to commence more rapidly
3. eliminates the need for the reversal of gantry frame rotation - correct answer...✔✔
1,2,3
CT is commonly referred to as all of the following except:
1. computerized axial tomography
2. digital subtraction angiography
3. CAT-scan
4. computed tomography - correct answer...✔✔2
Which of the following CT scanner designs does NOT use an x-ray tube?
1. first generation
2. PET/CT
3. electron beam CT
4. MDCT - correct answer...✔✔3
AGRADESOLUTIONS
, __________ allows remote authorized individuals to connect to a server in a secure
fashion using the routing infrastructure provided on a public network, such as the
internet. - correct answer...✔✔VPNs (virtual private networks)
Which technology do multi-row detector scanners employ? - correct answer...✔✔third-
generation
Which of the following statements is FALSE regarding the collection of CT data?
1. long scan times are more desirable because they average out motion artifacts
2. reconstruction process used to create the image occurs in the array processor
3. to collect the complete st of CT data, x-rays must be passed through the body at
many different angles
4. the detectors measure the x-rays which completely penetrate the patient - correct
answer...✔✔1
On a single-row detector scanner, collimation:
1. controls the slice thickness
2. minimizes the x-ray dose to the patient
3. reduces the detection of scatter radiation - correct answer...✔✔1,2,3
In a radiology department, a ________________ is a example of a "client" on the
network:
a. CT scanner
b. viewing console in the physicians reading room
c. printer for diagnostic images - correct answer...✔✔a,b,c
Which of the following is TRUE regarding multi-row detector for CT scanners?
1. size of the detector arrays along the z-direction may be different
2. the attenuation information from adjacent detector arrays may be added together to
generate thicker slices
3. all of the detectors arrays may or may not be used - correct answer...✔✔1,2,3
The CT x-ray tube rotates around the patient to:
1. keep the tube cool
2. generate projection views at different angles
3. minimize the x-ray dose administered to the patient - correct answer...✔✔2
Collimation:
1. accomplished by electrically blocking x-rays
2. affects scan time
3. limits low every x-ray photons and passed high energy photons
4. is accomplished by physically blocking x-rays - correct answer...✔✔4
Tungsten is used as the target material on the tubes anode because it has a _________
atomic number and a _________ melting point
AGRADESOLUTIONS
Les avantages d'acheter des résumés chez Stuvia:
Qualité garantie par les avis des clients
Les clients de Stuvia ont évalués plus de 700 000 résumés. C'est comme ça que vous savez que vous achetez les meilleurs documents.
L’achat facile et rapide
Vous pouvez payer rapidement avec iDeal, carte de crédit ou Stuvia-crédit pour les résumés. Il n'y a pas d'adhésion nécessaire.
Focus sur l’essentiel
Vos camarades écrivent eux-mêmes les notes d’étude, c’est pourquoi les documents sont toujours fiables et à jour. Cela garantit que vous arrivez rapidement au coeur du matériel.
Foire aux questions
Qu'est-ce que j'obtiens en achetant ce document ?
Vous obtenez un PDF, disponible immédiatement après votre achat. Le document acheté est accessible à tout moment, n'importe où et indéfiniment via votre profil.
Garantie de remboursement : comment ça marche ?
Notre garantie de satisfaction garantit que vous trouverez toujours un document d'étude qui vous convient. Vous remplissez un formulaire et notre équipe du service client s'occupe du reste.
Auprès de qui est-ce que j'achète ce résumé ?
Stuvia est une place de marché. Alors, vous n'achetez donc pas ce document chez nous, mais auprès du vendeur agradesolutions. Stuvia facilite les paiements au vendeur.
Est-ce que j'aurai un abonnement?
Non, vous n'achetez ce résumé que pour $9.99. Vous n'êtes lié à rien après votre achat.