Exam (elaborations)
CAMRT Study Guide Exam With Correct Questions And Answers 2024
CAMRT Study Guide Exam With Correct Questions And Answers 2024
[Show more]
Preview 2 out of 12 pages
Uploaded on
August 19, 2024
Number of pages
12
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
what
camrt study guide exam with correct questions
small pneumothorax what additional image to the r
pneumothorax picture in pa inspo what additional
shoulder aec hard soft tissue differentiation wh
Institution
CAMRT
Course
CAMRT
$14.49
100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached
CAMRT Study Guide Exam With Correct
Questions And Answers 2024
Small .pneumothorax: .what .additional .image .to .the .routine .pictures? .- .correct .answer.PA
.inspiration, .PA .expiration, .Lateral .(or .lateral .decub .with .affected .lung .UP) .
AEC .not .recommeneded .- .for .expiration .should .be .increased .by .1/3 .of .that .used .for
.inspiration .images
Pneumothorax .picture .in .PA .inspo: .what .additional .image .to .the .routine .pictures? .-
.correct .answer.PA .Expiration.... .
or .lateral .decub .with .affected .lung .up .(air .rising .to .the .highest .point .in .the .hemithorax .is
.more .clearly .visible .then .on .erect .views)
Shoulder .AEC .hard .soft .tissue .differentiation .- .what .factors .to .adjust? .- .correct
.answer.WINDOW .WIDTH .(narrower)
smaller .ww .to .enhance .the .amount .of .blacks .and .whites .showing .up .so .you .can .see .the
.small .differences .in .similar .HU
What .is .the .best .position .+ .SID .for .highest .spatial .resolution .for .C-spine .obliques? .RAO .-
.correct .answer.PA .(reduce .dose) .(LAO .RAO), .long .SID .(180cm)
Trauma: .AP .Caldwell .with .IOML .perpendicular, .how .much .angulation? .- .correct .answer.8
.cephalic .(to .compensate .for .the .OML)
What .is .seen .on .CT .of .an .intracranial .SOL? .- .correct .answer.Midline .shift .
OR
ventricle .compression
SOL .= .space .occupying .lesion
Pregnant .worker .already .with .1mSv .irradiated, .how .much .for .the .remainder .of .the
.pregnancy? .(declared .at .3 .months?) .- .correct .answer.4msv .total
3msv .for .remainder .of .pregnancy
Projection .for .orbits: .- .correct .answer.(AP .15 .Axial, .PA .15 .Axial, .PA .30 .Axial, .AP .30 .Axial)
Modified .waters .(modified .parietoacanthial .projection) .best .projection
, TMJ .image .- .angulation? .- .correct .answer.Axiolateral .projection .(Schuller .method): .25-30
.caudad .- .center .1.3cm .anterior .and .5cm .superior .to .upside .EAM .
Axiolateral .oblique .projection .(Modified .law .method): .15 .degree .caudal .angle .- .center
.1.5inch .superior .to .upside .EAM .
AP .axial .projection .(modified .towne): .angle .35-degrees .caudad .from .OML .OR .42-
degrees .from .IOML .- .center .3inches .superior .to .nasion.
Mandible .image .- .how .much .was .it .turned .(body .is .well .demonstrated?) .- .correct
.answer.30 .toward .IR
(45 .degree .rotation .demonstrates .mentum, .10-15 .degree .rotation .provides .a .general
.survey .of .the .mandible, .true .lateral .demonstrates .the .ramus)
Pelvis .ischial .spine .not .superimposed .over .the .pelvic .rim .- .closer .to .acetabulum .- .which
.way .is .it .rotated? .- .correct .answer.LPO .or .RPO .
If .the .left .ischial .spine .is .demonstrated .w/o .pelvic .brim .superimposition .then .it .is
.superimposed .on .the .right .acetabulum. .left .obturator .foramen .more .foreshortened .than
.right. .
In .pelvis .rotation, .the .upside .will .have .ischial .spine .superimposition .over .the .acetabulum.
Maxillary .sinus .opacified, .what .pathology .is .most .likely? .- .correct .answer.Blowout
.fracture- .pretty .freaking .sure
"opacification .of .the .sinus .caused .by .hemorrhage .and .mucosal .edema .is .an .indirect .sign
.of..this"
OR .sinusitis
Increase .HVL .= .tungsten .vaporization? .come .back .to .this .one. .- .correct .answer.HVL .is
.the .thickness .of .a .designated .absorber .required .to .decrease .the .intensity .of .the .primary
.beam .by .half .its .original .value. .
an .xray .beam .of .3-4.5mm .aluminium .is .considered .acceptable .when .kVp .ranges .from .80-
100. .
Increased .skin .dose, .inadequate .filtration .to .reduce .the .beam .to .half, .leakage .radiation
Optimal .image .of .pelvis .- .- .correct .answer.75-85 .kVp, .outer .cells, .grid,
Pelvis .taken .at .12mAs, .80 .kVP, .how .to .decrease .patient .dose? .- .correct .answer.15% .rule
.therefore .92 .kVp .and .6 .mAs
When .you .increase .kvp .by .15% .you .have .to .reduce .mAs .in .half .to .compensate
Nurse .standing .at .1m, .how .much .further .should .she .stand .to .decrease .dose .by .4x? .-
.correct .answer.2m
Port-a .cath .image- .(refrenace .kmart) .- .correct .answer.
hiatal .hernia .image .- .correct .answer.