100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4.2 TrustPilot
logo-home
Tentamen (uitwerkingen)

2024 BICSI –RETAKE PRACTICE TEST EXAM WITH CORRECT ANSWERS

Beoordeling
-
Verkocht
-
Pagina's
9
Cijfer
A+
Geüpload op
21-08-2024
Geschreven in
2024/2025

2024 BICSI –RETAKE PRACTICE TEST EXAM WITH CORRECT ANSWERS

Instelling
BICSI –RETAKE
Vak
BICSI –RETAKE









Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
BICSI –RETAKE
Vak
BICSI –RETAKE

Documentinformatie

Geüpload op
21 augustus 2024
Aantal pagina's
9
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

2024 BICSI –RETAKE PRACTICE
TEST EXAM WITH CORRECT
ANSWERS


The type of cutover where cross-connects are relocated one pair after
another until completed is called a - CORRECT-ANSWERSrolling cut 11-28

What is the width of the SBB? - CORRECT-ANSWERS2" (8-11, 8-16)

The _______ is a copper conductor that interconnects the SBB to the PBB -
CORRECT-ANSWERSTBB (8-11, 8-16)

The ________ bonds the electrical systems grounding electrode system to the
PBB. - CORRECT-ANSWERSTBC (8-11, 8-16)


The 2 main considerations concerning the existing cabling are? - CORRECT-
ANSWERSGrandfathered system
Abandoned cable 11-25

The ________ is the conductor used to connect the busbar to the ac electrical
panelboards - CORRECT-ANSWERSACEG (8-11, 8-16)

The recommended maximum value for the bonding resistance between the
grounding electrode and the busbar in the EF or TR is _______ milliohms -
CORRECT-ANSWERS100

Cabinets and racks should be set in place and leveled throughout the lineup.
Leveling foot adjustments or shimming of any anchoring point should not
exceed _______ inch(es) unless specified by the project engineer. - CORRECT-
ANSWERS0.5

The recommended minimum separation distance from electric motors and
transformers is ______ inches - CORRECT-ANSWERS48

Where optical fibers will be used, consider placing three innerducts ( two
_____ and one ____) inside each 4" conduit designated for this purpose to
ensure physical cable protection - CORRECT-ANSWERS1.5"
1"

, The minimum bend radius for coaxial cable (semi-rigid) is _________ time the
cable diameter - CORRECT-ANSWERS20

The minimum bend radius for intra-building optical fiber cable during
installation is _______ times the cable diameter. - CORRECT-ANSWERS15

The maximum pull force for two- to- four strand optical fiber is ______lbf -
CORRECT-ANSWERS50

Multipair copper cables require a minimum bend radius of _______ times their
diameter - CORRECT-ANSWERS10

*________ is a property of an electromagnetic field built around a conductor
that opposes any changes in current flow in a circuit. - CORRECT-
ANSWERSInductance

_______ is a property of conductors that allows storage of electrical charges
when potential differences ( voltages) exist between the conductors. -
CORRECT-ANSWERSCapacitance

The frequency of Category 8 cable is ______ - CORRECT-ANSWERS2000 MHz

Series _____ is the preferred choice for longer coaxial runs - CORRECT-
ANSWERS11

You would look in ANSI/TIA - _______ if you needed information on the labeling
standard - CORRECT-ANSWERS606

NEC ________ says that communication wires and cables shall be listed -
CORRECT-ANSWERS800

Commercial Building Telecommunications Infrastructure Standard -
CORRECT-ANSWERS568.1

The _______ provides space for an EF - CORRECT-ANSWERSEquipment room
(ER)

The color field for the "Common Equipment" termination field is _________ -
CORRECT-ANSWERSPurple

________cabling is the portion of the telecommunications cabling system that
connects the work areas to the other telecommunications spaces - CORRECT-
ANSWERSHorizontal

For all new installations, multipair backbone must meet the minimum
performance of category ______ cable - CORRECT-ANSWERS5e

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
Elitaa Chamberlain university
Bekijk profiel
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
172
Lid sinds
1 jaar
Aantal volgers
25
Documenten
7140
Laatst verkocht
23 uur geleden
A+ Academic Resources provides high-quality exam materials, assignments, past papers, and verified study documents to help students achieve top grades with confidence. Our resources are carefully organized to support effective learning.

We have just re-established our shop, my aim is to elevate and guide students academically with actual guides and exams 100% verified.Incase you dont find the exam that you are looking for,feel free to inbox me and request any exam.My prices are never fixed,always negotiable , WELCOME ,LETS BEGIN.

3.6

25 beoordelingen

5
10
4
5
3
5
2
1
1
4

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen