100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
CCI: Physics of Ultrasound-URR Questions With Answers Graded A+ Assured Success $7.99   Add to cart

Exam (elaborations)

CCI: Physics of Ultrasound-URR Questions With Answers Graded A+ Assured Success

 19 views  0 purchase
  • Course
  • CCI: Physics of Ultrasound-URR
  • Institution
  • CCI: Physics Of Ultrasound-URR

Frequencies used in transthoracic imaging are usually in the range of ____________. Frequencies used in transesophageal imaging are usually in the range of ______________. A) 3-6 MHz;6-8 MHz B) 3-6 MHz; 5-7 MHz C) 2.5-4 MHz; 5-7 MHz D) 1-3 MHz; 6-8 MHz - 2.5-4 MHz; 5-7 MHz Which of the follow...

[Show more]

Preview 3 out of 23  pages

  • August 25, 2024
  • 23
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • CCI: Physics of Ultrasound-URR
  • CCI: Physics of Ultrasound-URR
avatar-seller
PatrickKaylian
CCI: Physics of Ultrasound-URR
Frequencies used in transthoracic imaging are usually in the range of ____________. Frequencies used in
transesophageal imaging are usually in the range of ______________.

A) 3-6 MHz;6-8 MHz

B) 3-6 MHz; 5-7 MHz

C) 2.5-4 MHz; 5-7 MHz

D) 1-3 MHz; 6-8 MHz - 2.5-4 MHz; 5-7 MHz



Which of the following will aid in visualization of the endocardium?

A) Increased transducer frequency

B) Larger sector size

C) Increased wall filter

D) Agitated saline contrast - Increased transducer frequency-this will improve spatial and contrast
resolution




Which of the following adjustments will change the image data that will be stored in the memory of the
ultrasound system?

A) Both pre-processing and post-processing

B) Post-processing

C) Changing monitor contrast settings at the beginning of the exam.

D) Pre-Processing - Pre-processing-is performed as the image is "live" or in real time, before it has
been stored to memory.



Which measurement of beam intensity is used to describe levels of intensity associated with US
bioeffects?

A) Spatial peak temporal peak

B) Spatial average temporal peak

C) Spatial average temporal average

,D) Spatial peak temporal average - Spatial peak temporal average



Which of the following technical factors can negatively affect the 2D planimetry evaluation of the mitral
valve?

A) Valve masking from mechanical MVR and lateral resolution

B) Transducer with a short spatial pulse length and long wavelength

C) Lateral resolution and gain settings

D) Transducer with a short spatial pulse length and high frequency - Lateral resolution and gain
settings



________________ occurs posterior to highly attenuating structures.

A) Misregistration

B) Refraction

C) Shadowing

D) Enhancement - Shadowing



If you increase the power output on the machine:

A) Beam intensity and beam penetration increases

B) Beam intensity and the magnitude of the doppler shift increases

C) Beam intensity, resolution and beam penetration increase

D) Beam penetration and the magnitude of the doppler shift increase - Beam intensity and beam
penetration increase



All of the following are techniques used to better visualize the LV apex in the apical view, except?

A) Change to a lower frequency transducer

B) Contrast administration

C) Apply color doppler to the LV chamber

D) Adjust focal zone depth - Change to a lower frequency transducer-a lower frequency probe will
improve penetration but decrease resolution

, Which of the following ultrasound techniques has the highest temporal resolution?

A) 3D imaging

B) 2D imaging

C) Color doppler

D) M-Mode - M-Mode



Lateral resolution is defined as:

A) The ability to differentiate two reflectors that are perpendicular to the US beam

B) The ability to differentiate two reflectors that are moving in a direction parallel to the US beam

C) The ability to differentiate two reflectors that are parallel to the US beam

D) The ability to differentiate two reflectors that are moving in a direction that is perpendicular to the US
beam - The ability to differentiate two reflectors that are parallel to the US beam




When does aliasing occur? - When the frequency shift exceeds the PRF of the transducer



Which of the following system control adjustments will increase the amount of color doppler that is
superimposed over the 2D image?

A) Increased threshold and increased persistence

B) Decrease persistence

C) Increased wall filter

D) Decreased threshold - Increased threshold and increased persistence-Threshold control=Color
priority



While scanning the heart from the apical window, the ventricular chambers are anechoic but artifactual
echoes appear to fill the atria. Which of the following adjustments of the system controls would best
address this issue?

A) Decrease near field gain levels

B) Switch to a higher frequency transducer

C) Increase output power to increase penetration

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller PatrickKaylian. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $7.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

72042 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$7.99
  • (0)
  Add to cart